10. Service Mode
Field Service Ver. 1.0 Apr. 2005
86
ineo 161
ineo 210
Adjustment / Setting
H. FUSER TEMP. Ad (OHP)
<Temperature table for adjusting fusing temperature for OHP film>
For ineo 161
For ineo 210
Purpose/Use
To set the fusing temperature when OHP film are used.
✽
When fusing failure occurs
Setting/
Procedure
• The default setting is “0.”
Setting range: -1 to +1
Setting value
Paper width
Mode selected in Service’s Choice
Mode 1
Mode 3
CD
Fusing Heater Lamp temperature
1
251 mm or more
180
°
C
175
°
C
250 mm or less
165
°
C
165
°
C
0 (default value)
251 mm or more
180
°
C
165
°
C
250 mm or less
155
°
C
155
°
C
-1
251 mm or more
170
°
C
155
°
C
250 mm or less
145
°
C
145
°
C
Setting value
Mode selected in Service’s Choice
Mode 1
Mode 3
Fusing Heater Lamp temperature (main/sub)
1
175
°
C
0 (default value)
165
°
C
-1
155
°
C