12. Mechanical adjustment
Field Service Ver. 1.0 Apr. 2005
114
ineo 161
ineo 210
Adjustment / Setting
12.4 Manual Bypass (for the optional AD-504) CD Registration
Adjustment *ineo 210 only
NOTE
• This adjustment is to be made when the PH Unit has been replaced.
<Adjustment Procedure>
1.
Load the Paper Feed Tray/1 with A4 crosswise paper.
2.
Enter Function of the Service mode.
3.
Select “Print Test Pattern” and then “Test Pattern1.” Then, press the Start key.
✽
This will produce a test pattern.
4.
Place the test pattern produced on the Original Glass.
5.
Load A4 crosswise paper in the Manual Bypass and make a test copy.
6.
Check width A on the copy of the test
pattern.
If width A falls outside the specified
range, perform the following steps to
make an adjustment.
Specifications
20 ± 2.0 mm
7.
Open the Right Door.
8.
Remove two screws and the Manual
Bypass Cover.
9.
Loosen two screws on the Manual
Bypass and adjust the position of the
Manual Bypass.
Adjustment Instructions
If width A on the copy is smaller than
width A on the test pattern, move the
Manual Bypass toward the rear of the
copier.
If width A on the copy is greater than
width A on the test pattern, move the
Manual Bypass toward the front of the
copier.
10. Make another copy of the test pat-
tern and check for any error in width
A.
A
4686D504AA
4532U028AA
4532U029AA