Field Service Ver. 1.0 Aug. 2005
11. Tech. Rep. Mode
191
bizhub 200/250/350
Adjustment / Setting
11.11.9
List of the CS Remote Care error code
A. For telephone line modem
Error code
Error
Solution
0001
The line is busy (Busy detection)
• Transmit again manually.
0002
Failure of the Modem default setting at transmit-
ting (When the transmission completes with
modem initial setting failed)
• Check if the power of the
modem is ON.
• Check the connecting condition
between the modem and the
main unit.
0003
Timeout of CONNECT at transmitting
(No response to ATD)
• Transmit again manually
• Check if the power of the
modem is ON.
• Check the connecting condition
between the modem and the
main unit.
0004
Timeout of Incoming request response
(No response to incoming (starting) request
MSG)
• Contact responsible person of
KONICA MINOLTA.
0005
Timeout of CONNECT at receiving
(No response to ATA)
• Check if the power of the
modem is ON.
• Check the connecting condition
between the modem and the
main unit.
0006
Shut down of the data modem line (Host)
(Carrier OFF is detected)
• No solution, because the line is
shut down at the host side.
0007
Shut down of the data modem line (Main unit)
(Line is shut down forcibly due to event)
• Contact responsible person of
KONICA MINOLTA.
0008
Timeout of start request telegram delivery
(Start request telegram is not delivered after line
connection)
• Transmit again manually.
0009
Timeout of finish request telegram delivery
(Finish request telegram is not delivered (Start of
shut down).)
• Transmit again manually.
000A
Receiving rejection
(Receiving is made when the main unit is set to
reject receiving.)
• Check the setting condition of
the host side.
• Check the setting condition of
the main unit side.
000B
RS232C Driver Over Run
(When the modem detects Over Run.)
• If the same error is detected
several times, turn the modem
power OFF and ON.
000C
If the same error is detected several times, turn
the modem power OFF and ON.
• If the same error is detected
several times, turn the modem
power OFF and ON.
000D
Break Interrupt (BI) Indicator
(When the modem detects Break Interrupt (BI)
Indicator.)
• If the same error is detected
several times, turn the modem
power OFF and ON.
000E
Receiving RING Buffer Full
(When the Receiving RING Buffer is full.)
• Contact responsible person of
KONICA MINOLTA.
000F
Transmitting RING Buffer Full
(When the Transmitting RING Buffer is full.)
• Contact responsible person of
KONICA MINOLTA.
Summary of Contents for ineo 250
Page 1: ...ineo 250 350 Dynamic balance www develop de Service Manual Field ...
Page 21: ...SAFETY AND IMPORTANT WARNING ITEMS S 18 4040P0C501DA High voltage ...
Page 26: ...ineo 250 350 Main Unit Dynamic balance www develop de Service Manual Field ...
Page 45: ...3 Built in Controllers Field Service Ver 1 0 Aug 2005 6 bizhub 200 250 350 General Blank Page ...
Page 331: ...25 Timing chart Field Service Ver 1 0 Aug 2005 292 bizhub 200 250 350 Appendix 4040F5E522DA ...
Page 334: ...Duplex Unit Switchback Unit Dynamic balance www develop de Service Manual Field ...
Page 352: ...ineo 250 350 Standard Controller Dynamic balance www develop de Service Manual Field ...
Page 364: ...FK 503 Dynamic balance www develop de Service Manual Field ...
Page 373: ...1 Product specifications Field Service Ver 1 0 Aug 2005 4 FK 503 General Blank Page ...
Page 379: ...4 Disassembly Reassembly Field Service Ver 1 0 Aug 2005 10 FK 503 Maintenance Blank Page ...
Page 529: ...11 Soft Switch List Field Service Ver 1 0 Aug 2005 160 FK 503 Adjustment Setting Blank Page ...
Page 542: ...DF 605 Dynamic balance www develop de Service Manual Field ...
Page 549: ...1 Product specifications Field Service Ver 1 0 Aug 2005 4 DF 605 General Blank Page ...
Page 578: ...PC 102 PC 202 Dynamic balance www develop de Service Manual Field ...
Page 583: ...1 Product specifications Field Service Ver 1 0 Aug 2005 2 PC 102 PC 202 General Blank Page ...
Page 609: ...8 Trouble code Field Service Ver 1 0 Aug 2005 28 PC 102 PC 202 Troubleshooting Blank Page ...
Page 610: ...PC 402 Dynamic balance www develop de Service Manual Field ...
Page 615: ...1 Product specification Field Service Ver 1 0 Aug 2005 2 PC 402 General Blank Page ...
Page 629: ...3 Other Field Service Ver 1 0 Aug 2005 16 PC 402 Maintenance Blank Page ...
Page 649: ...8 Trouble code Field Service Ver 1 0 Aug 2005 36 PC 402 Troubleshooting Blank Page ...
Page 650: ...JS 502 Dynamic balance www develop de Service Manual Field ...
Page 653: ...JS 502 General Maintenance Adjustment Setting Field Service Ver 1 0 Aug 2005 ii Blank Page ...
Page 655: ...1 System configuration Field Service Ver 1 0 Aug 2005 2 JS 502 General Blank Page ...
Page 660: ...FS 508 PU 501 OT 601 Dynamic balance www develop de Service Manual Field ...
Page 687: ...4 Other Field Service Ver 1 0 Aug 2005 22 FS 508 PU 501 OT 601 Maintenance Blank Page ...
Page 714: ...MT 501 Dynamic balance www develop de Service Manual Field ...
Page 719: ...1 Product specification Field Service Ver 1 0 Aug 2005 2 MT 501 General Blank Page ...
Page 732: ...SD 502 Dynamic balance www develop de Service Manual Field ...
Page 737: ...1 Product specifications Field Service Ver 1 0 Aug 2005 2 SD 502 General Blank Page ...