7. Mechanical adjustment
Field Service Ver. 1.0 Aug. 2005
22
DF-605
Adjustment / Setting
7.
Mechanical adjustment
7.1
Leading Edge Skew Adjustment
1.
Load the test chart [1] in the Reverse
Automatic Document Feeder and
make one 1-sided copy five consecu-
tive times.
2.
Fold each of the sample copies as
illustrated and check for any devia-
tion.
Specifications: 0 ± 3.0 mm
3.
If the deviation does not fall within
the specified range, perform the fol-
lowing adjustment procedure.
4.
Loosen the decorative screw [2] and
the nut [3] in the back to the right.
5.
If there is a deviation as shown on
the figure, turn the screw counter-
clockwise to adjust it.
4344F3C501DA
[1]
4344F3C502DA
[3]
[2]
4344F3C503DA
Summary of Contents for ineo 250
Page 1: ...ineo 250 350 Dynamic balance www develop de Service Manual Field ...
Page 21: ...SAFETY AND IMPORTANT WARNING ITEMS S 18 4040P0C501DA High voltage ...
Page 26: ...ineo 250 350 Main Unit Dynamic balance www develop de Service Manual Field ...
Page 45: ...3 Built in Controllers Field Service Ver 1 0 Aug 2005 6 bizhub 200 250 350 General Blank Page ...
Page 331: ...25 Timing chart Field Service Ver 1 0 Aug 2005 292 bizhub 200 250 350 Appendix 4040F5E522DA ...
Page 334: ...Duplex Unit Switchback Unit Dynamic balance www develop de Service Manual Field ...
Page 352: ...ineo 250 350 Standard Controller Dynamic balance www develop de Service Manual Field ...
Page 364: ...FK 503 Dynamic balance www develop de Service Manual Field ...
Page 373: ...1 Product specifications Field Service Ver 1 0 Aug 2005 4 FK 503 General Blank Page ...
Page 379: ...4 Disassembly Reassembly Field Service Ver 1 0 Aug 2005 10 FK 503 Maintenance Blank Page ...
Page 529: ...11 Soft Switch List Field Service Ver 1 0 Aug 2005 160 FK 503 Adjustment Setting Blank Page ...
Page 542: ...DF 605 Dynamic balance www develop de Service Manual Field ...
Page 549: ...1 Product specifications Field Service Ver 1 0 Aug 2005 4 DF 605 General Blank Page ...
Page 578: ...PC 102 PC 202 Dynamic balance www develop de Service Manual Field ...
Page 583: ...1 Product specifications Field Service Ver 1 0 Aug 2005 2 PC 102 PC 202 General Blank Page ...
Page 609: ...8 Trouble code Field Service Ver 1 0 Aug 2005 28 PC 102 PC 202 Troubleshooting Blank Page ...
Page 610: ...PC 402 Dynamic balance www develop de Service Manual Field ...
Page 615: ...1 Product specification Field Service Ver 1 0 Aug 2005 2 PC 402 General Blank Page ...
Page 629: ...3 Other Field Service Ver 1 0 Aug 2005 16 PC 402 Maintenance Blank Page ...
Page 649: ...8 Trouble code Field Service Ver 1 0 Aug 2005 36 PC 402 Troubleshooting Blank Page ...
Page 650: ...JS 502 Dynamic balance www develop de Service Manual Field ...
Page 653: ...JS 502 General Maintenance Adjustment Setting Field Service Ver 1 0 Aug 2005 ii Blank Page ...
Page 655: ...1 System configuration Field Service Ver 1 0 Aug 2005 2 JS 502 General Blank Page ...
Page 660: ...FS 508 PU 501 OT 601 Dynamic balance www develop de Service Manual Field ...
Page 687: ...4 Other Field Service Ver 1 0 Aug 2005 22 FS 508 PU 501 OT 601 Maintenance Blank Page ...
Page 714: ...MT 501 Dynamic balance www develop de Service Manual Field ...
Page 719: ...1 Product specification Field Service Ver 1 0 Aug 2005 2 MT 501 General Blank Page ...
Page 732: ...SD 502 Dynamic balance www develop de Service Manual Field ...
Page 737: ...1 Product specifications Field Service Ver 1 0 Aug 2005 2 SD 502 General Blank Page ...