7. Jam Display
Field Service Ver. 1.0 Aug. 2005
24
PC-102/PC-202
T
roubleshooting
7.3.2
Tray3 Paper Take-Up section/Vertical Transport section misfeed (PC-102/
PC-202)
A. Detection timing
B. Action
Type
Description
Tray3 Paper Take-Up section/
Vertical transport section
misfeed detection
The leading edge of the paper does not block the Tray3 Vertical Convey-
ance Sensor (PC117-PF) even after the set period of time has elapsed
after the Tray3 Paper Feed Motor (M122-PF) is energized.
The Vertical Conveyance Sensor (PC2) is not blocked even after the
lapse of a given period of time after the Tray3 Vertical Conveyance Sen-
sor (PC117-PF) has been blocked by a paper.
The Tray3 Vertical Conveyance Sensor (PC117-PF) is not unblocked
even after the lapse of a given period of time after PC117-PF has been
blocked by a paper.
Tray3 detection of paper
remaining
The Tray3 Vertical Conveyance Sensor (PC117-PF) is blocked when the
Main Power Switch is set to ON, a door or cover is opened and closed,
or a misfeed or malfunction is reset.
The Tray3 Paper Take-Up Sensor (PC116-PF) is blocked when the Main
Power Switch is set to ON, a door or cover is opened and closed, or a
misfeed or malfunction is reset.
Relevant electrical parts
Tray3 Paper Take-Up Sensor (PC116-PF)
Tray3 Vertical Conveyance Sensor (PC117-PF)
Vertical Conveyance Sensor (PC2)
Tray3 Paper Feed Motor (M122-PF)
Main Control Board (PWB-C2 PF)
Step
Action
WIRING DIAGRAM
Control signal
Location (Electrical
components)
1
Initial check items
-
-
2
PC116-PF sensor check
PWB-C2 PF PJ6C2 PF-8 (ON)
PC-202 C-4
3
PC117-PF sensor check
PWB-C2 PF PJ6C2 PF-11 (ON)
PC-202 C-4
4
PC2 sensor check
PWB-A PJ22A-9 (ON)
D-7
5
M122-PF operation check
PWB-C2 PF PJ5C2 PF-1 to 4
PC-202 C-4
6
PWB-C2 PF replacement
-
-
Summary of Contents for ineo 250
Page 1: ...ineo 250 350 Dynamic balance www develop de Service Manual Field ...
Page 21: ...SAFETY AND IMPORTANT WARNING ITEMS S 18 4040P0C501DA High voltage ...
Page 26: ...ineo 250 350 Main Unit Dynamic balance www develop de Service Manual Field ...
Page 45: ...3 Built in Controllers Field Service Ver 1 0 Aug 2005 6 bizhub 200 250 350 General Blank Page ...
Page 331: ...25 Timing chart Field Service Ver 1 0 Aug 2005 292 bizhub 200 250 350 Appendix 4040F5E522DA ...
Page 334: ...Duplex Unit Switchback Unit Dynamic balance www develop de Service Manual Field ...
Page 352: ...ineo 250 350 Standard Controller Dynamic balance www develop de Service Manual Field ...
Page 364: ...FK 503 Dynamic balance www develop de Service Manual Field ...
Page 373: ...1 Product specifications Field Service Ver 1 0 Aug 2005 4 FK 503 General Blank Page ...
Page 379: ...4 Disassembly Reassembly Field Service Ver 1 0 Aug 2005 10 FK 503 Maintenance Blank Page ...
Page 529: ...11 Soft Switch List Field Service Ver 1 0 Aug 2005 160 FK 503 Adjustment Setting Blank Page ...
Page 542: ...DF 605 Dynamic balance www develop de Service Manual Field ...
Page 549: ...1 Product specifications Field Service Ver 1 0 Aug 2005 4 DF 605 General Blank Page ...
Page 578: ...PC 102 PC 202 Dynamic balance www develop de Service Manual Field ...
Page 583: ...1 Product specifications Field Service Ver 1 0 Aug 2005 2 PC 102 PC 202 General Blank Page ...
Page 609: ...8 Trouble code Field Service Ver 1 0 Aug 2005 28 PC 102 PC 202 Troubleshooting Blank Page ...
Page 610: ...PC 402 Dynamic balance www develop de Service Manual Field ...
Page 615: ...1 Product specification Field Service Ver 1 0 Aug 2005 2 PC 402 General Blank Page ...
Page 629: ...3 Other Field Service Ver 1 0 Aug 2005 16 PC 402 Maintenance Blank Page ...
Page 649: ...8 Trouble code Field Service Ver 1 0 Aug 2005 36 PC 402 Troubleshooting Blank Page ...
Page 650: ...JS 502 Dynamic balance www develop de Service Manual Field ...
Page 653: ...JS 502 General Maintenance Adjustment Setting Field Service Ver 1 0 Aug 2005 ii Blank Page ...
Page 655: ...1 System configuration Field Service Ver 1 0 Aug 2005 2 JS 502 General Blank Page ...
Page 660: ...FS 508 PU 501 OT 601 Dynamic balance www develop de Service Manual Field ...
Page 687: ...4 Other Field Service Ver 1 0 Aug 2005 22 FS 508 PU 501 OT 601 Maintenance Blank Page ...
Page 714: ...MT 501 Dynamic balance www develop de Service Manual Field ...
Page 719: ...1 Product specification Field Service Ver 1 0 Aug 2005 2 MT 501 General Blank Page ...
Page 732: ...SD 502 Dynamic balance www develop de Service Manual Field ...
Page 737: ...1 Product specifications Field Service Ver 1 0 Aug 2005 2 SD 502 General Blank Page ...