TROUBLESHOOTING GUIDE (Continued)

CORRECTION

CAUSE

Possible defect in safety valve.

Knocking Noise

Compressor is not supplying
enough air to operate accesso-
ries.

Prolonged excessive use of air.

Decrease amount of air usage.

Hole in hose.

Remove and clean, or replace.

Air leaks.

Tighten fittings.  (See Air Leaks Section of Trou-
bleshooting Guide.)

Motor will not run.

Check valve restricted.

Check and replace.

Check the accessory air requirement.  If it is higher
than the SCFM or pressure supplied by your air
compressor, you need a larger compressor.

Compressor is not large enough for air
requirement.

Defective check valve.

Remove and clean, or replace.

Operate safety valve manually by pulling on ring.  If
valve still leaks, it should be replaced.

Air leak from safety valve.

PROBLEM

Motor will start automatically when tank pressure
drops below “cut-in” pressure of pressure switch.

Tank pressure exceeds pressure switch
“cut-in” pressure.

Check for proper gauge wire and cord length.

Wrong gauge wire or length of exten-
sion cord.

Loose  electrical  connections.

Check wiring connection inside pressure switch and
terminal box area.

Remove and clean, or replace.

Check valve stuck open.

Paint spray on internal motor parts.

Have checked at an Authorized Warranty Service
Center.  Do not operate the compressor in the paint
spray area.  See flammable vapor warning.

Possible defective motor.

Have checked at an Authorized Warranty Service
Center.

1.

Check fuse box for blown fuse and replace, if
necessary.  Reset circuit breaker. Do not use a
fuse or circuit breaker with higher rating than that
specified for your particular branch circuit.

2.

Check for proper fuse.

3.

Check for low voltage conditions and/or proper
extension cord.

4.

Disconnect the other electrical appliances from
circuit or operate the compressor in its own
branch circuit.

Fuse blown, circuit breaker tripped.

Damaged regulator.

Replace regulator.

Regulator knob has continuous
air leak. Regulator will not shut off
at air outlet.

Summary of Contents for FA125

Page 1: ...ssor Part number and description of the item you wish to purchase OWNERS MANUAL FOR PERMANENTLY LUBRICATED AIR COMPRESSOR For Home Use Only SAFETYGUIDELINES 1 WARRANTY 2 WARNINGCHART 3 4 GLOSSARY 5 DU...

Page 2: ...tact the nearest Authorized Warranty Service Center that provides on site service calls for service call arrangement o If the purchaser does not receive satisfactory results from the Authorized Warran...

Page 3: ...MPRESSOR OUTFIT NEVER DRILL INTO WELD OR MAKE ANY MODIFICATIONS TO THE TANK OR ITS ATTACHMENTS THE TANK IS DESIGNED TO WITHSTAND SPECIFIC OPERATING PRESSURES NEVER MAKE ADJUSTMENTS OR PARTS SUBSTI TUT...

Page 4: ...Y ELECTRICAL WIRING OR REPAIRS REQUIRE ON THIS PRODUCT SHOULD BE PERFORMED BY AUTHORIZED SERVICE CENTER PERSONNEL IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES MAKE CERTAIN THAT THE ELECTRICA...

Page 5: ...ressure drops to approximately 100 PSI the motor will restart automatically The low pressure at 1 Set the ON OFF switch to OFF and unplug the cord 2 Review the Operating Procedures section page 8 Be s...

Page 6: ...compressor in good condition no longer than 50 feet 14gauge AWG orlarger Wiresizeincreasesas gaugenumberdecreases 12AWG 10AWGand 8AWGmayalsobeused DONOTUSE16OR18 AWG Location of the Air Compressor Yo...

Page 7: ...he following break in instructions are not closely followed The air compressor is equipped with a cord having a grounded wire with an appropriate grounding plug The plug must be used with an outlet th...

Page 8: ...lever to AUTO and allow tank pressuretobuild Motorwillstopwhentankpressure reaches cut out pressure 4 Opentheregulatorbyturningitclockwise Adjustthe regulator to the correct pressure setting Your com...

Page 9: ...ective pressure release valve Defective check valve Air leaks at pressure switch release valve Remove and replace the release valve Air leaks in air tank or at air tank welds DO NOT DRILL INTO WELD OR...

Page 10: ...Tankpressureexceedspressureswitch cut in pressure Check for proper gauge wire and cord length Wrong gauge wire or length of exten sion cord Loose electrical connections Check wiring connection inside...

Page 11: ...RAIN VALVE Not Shown CHECKVALVE Not Shown ISOLATOR DESCRIPTION PART NUMBER REGULATOR CAC 4296 1 TANK PRESSURE GAUGE GA 345 OUTLET PRESSURE GUAGE GA 345 SAFETY VALVE TIA 4150 DRAIN VALVE SS 2707 CHECK...

Page 12: ...ower Company 213 Industrial Drive Jackson TN 38301 9615 WARRANTY This product is covered by the DeVilbiss one year limited warranty The warranty can be found in the General Manual or is available upon...

Reviews: