background image

9 - ENG

Defective air tank.

CORRECTION

Excessive tank pressure - safety
valve pops off.

Pressure switch does not shut off mo-
tor when compressor reaches “cut-
out” pressure.

Move the pressure switch lever to the “OFF” position.
If the outfit doesn’t shut off, unplug. If the electrical
contacts are welded together, replace the pressure
switch.

Pressure '"cut-out" too high.

Return the outfit to an authorized dealer to check and
adjust, or replace switch.

PROBLEM

Air leaks at fittings.

Tube fittings are not tight enough.

Tighten fittings where air can be heard escaping.
Check fittings with soapy water solution. 

DO NOT

OVER-TIGHTEN.

Air leaks at or inside check
valve.

Defective or dirty check valve.

A defective check valve results in a constant air leak
at the pressure release valve when there is pressure
in the tank and the compressor is shut off.  Remove
and clean or replace check valve.  

DO NOT OVER-

TIGHTEN.

Defective pressure release valve.

Defective check valve.

Air leaks at pressure switch
release valve.

Remove and replace the release valve.

Air leaks in air tank or at air tank
welds.

DO NOT DRILL INTO, WELD OR OTHERWISE
MODIFY AIR TANK OR IT WILL WEAKEN.
THE TANK CAN RUPTURE OR EXPLODE.

TROUBLESHOOTING  GUIDE

PERFORMING REPAIRS MAY EXPOSE VOLTAGE SOURCES, MOVING PARTS OR COMPRESSED
AIR SOURCES.  PERSONAL INJURY MAY OCCUR.  PRIOR TO ATTEMPTING ANY REPAIRS,
UNPLUG THE COMPRESSOR AND BLEED OFF TANK AIR PRESSURE.

CAUSE

Pressure reading on the regu-
lated pressure gauge drops
when an accessory is used.

It is normal for “some” pressure drop to
occur.

If there is an excessive amount of pressure drop when
the accessory is used, adjust the regulator following
the instructions on page 6.

NOTE

Adjust the regulated pressure under
flow conditions (while accessory is be-
ing  used).

Air tank must be replaced.  Do not repair the leak.

A defective check valve results in a constant air leak
at the pressure release valve when there is pressure
in the tank and the compressor is shut off.  Remove
and clean or replace check valve.  

DO NOT OVER-

TIGHTEN.

Summary of Contents for FA125

Page 1: ...ssor Part number and description of the item you wish to purchase OWNERS MANUAL FOR PERMANENTLY LUBRICATED AIR COMPRESSOR For Home Use Only SAFETYGUIDELINES 1 WARRANTY 2 WARNINGCHART 3 4 GLOSSARY 5 DU...

Page 2: ...tact the nearest Authorized Warranty Service Center that provides on site service calls for service call arrangement o If the purchaser does not receive satisfactory results from the Authorized Warran...

Page 3: ...MPRESSOR OUTFIT NEVER DRILL INTO WELD OR MAKE ANY MODIFICATIONS TO THE TANK OR ITS ATTACHMENTS THE TANK IS DESIGNED TO WITHSTAND SPECIFIC OPERATING PRESSURES NEVER MAKE ADJUSTMENTS OR PARTS SUBSTI TUT...

Page 4: ...Y ELECTRICAL WIRING OR REPAIRS REQUIRE ON THIS PRODUCT SHOULD BE PERFORMED BY AUTHORIZED SERVICE CENTER PERSONNEL IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES MAKE CERTAIN THAT THE ELECTRICA...

Page 5: ...ressure drops to approximately 100 PSI the motor will restart automatically The low pressure at 1 Set the ON OFF switch to OFF and unplug the cord 2 Review the Operating Procedures section page 8 Be s...

Page 6: ...compressor in good condition no longer than 50 feet 14gauge AWG orlarger Wiresizeincreasesas gaugenumberdecreases 12AWG 10AWGand 8AWGmayalsobeused DONOTUSE16OR18 AWG Location of the Air Compressor Yo...

Page 7: ...he following break in instructions are not closely followed The air compressor is equipped with a cord having a grounded wire with an appropriate grounding plug The plug must be used with an outlet th...

Page 8: ...lever to AUTO and allow tank pressuretobuild Motorwillstopwhentankpressure reaches cut out pressure 4 Opentheregulatorbyturningitclockwise Adjustthe regulator to the correct pressure setting Your com...

Page 9: ...ective pressure release valve Defective check valve Air leaks at pressure switch release valve Remove and replace the release valve Air leaks in air tank or at air tank welds DO NOT DRILL INTO WELD OR...

Page 10: ...Tankpressureexceedspressureswitch cut in pressure Check for proper gauge wire and cord length Wrong gauge wire or length of exten sion cord Loose electrical connections Check wiring connection inside...

Page 11: ...RAIN VALVE Not Shown CHECKVALVE Not Shown ISOLATOR DESCRIPTION PART NUMBER REGULATOR CAC 4296 1 TANK PRESSURE GAUGE GA 345 OUTLET PRESSURE GUAGE GA 345 SAFETY VALVE TIA 4150 DRAIN VALVE SS 2707 CHECK...

Page 12: ...ower Company 213 Industrial Drive Jackson TN 38301 9615 WARRANTY This product is covered by the DeVilbiss one year limited warranty The warranty can be found in the General Manual or is available upon...