background image

MODEL NO.

FA153

FAC153

MGP-FA153A    10/1/97

SAFETY GUIDELINES - DEFINITIONS

Information for preventing damage to
equipment.

This manual contains information
that is important for you to know
and understand. This information
relates to protecting 

YOUR

SAFETY

 and 

PREVENTING

EQUIPMENT PROBLEMS

. To

help you recognize this informa-
tion, we use the symbols to the
right. Please read the manual and
pay attention to these sections.

URGENT SAFETY INFORMATION - A HAZARD
THAT WILL CAUSE SERIOUS INJURY OR LOSS
OF  LIFE.

Information that you should pay
special attention to.

IMPORTANT SAFETY INFORMATION - A
HAZARD THAT 

MIGHT 

CAUSE SERIOUS

INJURY OR LOSS OF LIFE.

Call our

 Toll Free Number 1-800-888-2468, Ext 2, then 1,

 to obtain the location of the nearest Authorized Service

Center for ordering repair parts and for warranty repairs.

When ordering repair parts from your local Authorized Service Center, always give the following information:

• Model number of your compressor
• Part number and description of the item you wish to purchase

OWNERS MANUAL FOR

PERMANENTLY LUBRICATED AIR COMPRESSOR

(For Home Use Only)

SAFETY GUIDELINES .......................................................

1

WARRANTY .......................................................................

2

WARNING CHART .........................................................

3-4

GLOSSARY ........................................................................

5

DUTY CYCLE .....................................................................

5

STORAGE ...........................................................................

5

DESCRIPTION OF OPERATION .......................................

6

INSTALLATION AND BREAK-IN
PROCEDURES ..............................................................

6-7

Location of Air Compressor ........................................ 6
Extension Cords .......................................................... 6
Voltage and Circuit Protection ..................................... 6
Grounding Instructions ............................................... 7
Additional Regulators and Controls ............................ 7
Break-In Procedures .................................................... 7

OPERATING PROCEDURES ............................................

8

TROUBLESHOOTING GUIDE .....................................

9-10

COMPRESSOR PARTS LIST ..........................................

11

TABLE OF CONTENTS

MODEL NO.

Horsepower
SCFM @ 40 psig
SCFM @ 90 psig
Cut-In
Cut-Out
Bore
Stroke
Voltage/Hertz/ Phase
Minimum Branch Circuit
   Requirement
*Fuse Type
Amperage at Max. Load
Tank Size

SPECIFICATION CHART

*A circuit breaker is preferred. Use only a fuse or
circuit breaker that is the same rating as the branch
circuit the air compressor is operated on. If the air
compressor is connected to a circuit protected by
fuses, use quick acting fuses.

FA153

1.5
4.0
2.9

100  PSI

125 PSI

1 7/8"
1 1/4"

120/60/1

15 AMPS

Quick Acting

10 AMPS

3  Gallon

FAC153

-----

4.0
2.9

100  PSI

125 PSI

1 7/8"
1 1/4"

120/60/1

15 AMPS

Quick Acting

10 AMPS

3  Gallon

Summary of Contents for FA153

Page 1: ...essor Part number and description of the item you wish to purchase OWNERS MANUAL FOR PERMANENTLY LUBRICATED AIR COMPRESSOR For Home Use Only SAFETY GUIDELINES 1 WARRANTY 2 WARNING CHART 3 4 GLOSSARY 5...

Page 2: ...service call arrangement If the purchaser does not receive satisfactory results from the Authorized Warranty Service Center the purchaser should contact DeVilbiss Air Power Company Merchandise sold a...

Page 3: ...MAKE ANY MODIFICATIONS TO THE TANK or its attachments Never attempt to repair a damaged or leaking tank Replace with a new tank The tank is designed to withstand specific operating pressures NEVER MAK...

Page 4: ...ctly or from a breathing device connected to the compressor WORK IN AN AREA equipped WITH GOOD CROSS VENTILATION Read and FOLLOW THE SAFETY INSTRUCTIONS provided on the label or safety data sheet FOR...

Page 5: ...k pressure drops to approximately 100 PSI the motor will restart automatically The low pressure at 1 Set the ON OFF switch to OFF and unplug the cord 2 Reviewthe OperatingProcedures section page9 Be s...

Page 6: ...will accept the plug on the compressor ingoodcondition no longer than 50 feet 14 gauge AWG or larger Wire size increases as gaugenumberdecreases 12AWG 10AWGand 8 AWG may also be used DO NOT USE 16 OR...

Page 7: ...lt if the followingbreak ininstructionsare notcloselyfollowed The air compressor is equipped with a cord having a grounded wire with an appropriate grounding plug The plug must be used with an outlet...

Page 8: ...F AUTO lever to AUTO and allow tank pressuretobuild Motorwillstopwhentankpressure reaches cut out pressure 4 Opentheregulatorbyturningitclockwise Adjustthe regulator to the correct pressure setting Yo...

Page 9: ...eaks at pressure switch re leasevalve Remove and replace the release valve DO NOT DRILL INTO WELD OR OTHERWISE MODIFY AIR TANK OR IT WILL WEAKEN THE TANK CAN RUPTURE OR EXPLODE TROUBLESHOOTING GUIDE P...

Page 10: ...Tankpressureexceedspressureswitch cut in pressure Check for proper gauge wire and cord length Wrong gauge wire or length of exten sion cord Loose electrical connections Check wiring connection inside...

Page 11: ...ANK DRAIN VALVE Not Shown CHECKVALVE Not Shown ISOLATOR DESCRIPTION PART NUMBER REGULATOR CAC 4296 1 TANK PRESSURE GAUGE C GA 345 OUTLET PRESSURE GUAGE C GA 345 SAFETY VALVE TIA 4150 DRAIN VALVE SS 27...

Page 12: ...ower Company 213 Industrial Drive Jackson TN 38301 9615 WARRANTY This product is covered by the DeVilbiss one year limited warranty The warranty can be found in the General Manual or is available upon...