background image

9 - ENG

CORRECTION

Excessive tank pressure - safety
valve pops off.

Pressure switch does not shut off mo-
tor when compressor reaches “cut-
out” pressure.

Move the pressure switch lever to the “OFF” position.
If the outfit doesn’t shut off, unplug. If the electrical
contacts are welded together, replace the pressure
switch.

Pressure  '"cut-out"  too  high.

Return the outfit to an authorized dealer to check and
adjust, or replace switch.

PROBLEM

Air leaks at fittings.

Tube fittings are not tight enough.

Tighten fittings where air can be heard escaping.
Check fittings with soapy water solution. 

DO NOT

OVER-TIGHTEN.

Air leaks at or inside check valve.

A defective check valve results in a constant air leak at
the pressure release valve when there is pressure in the
tank and the compressor is shut off.  Remove and clean
or replace check valve.  

DO NOT OVER-TIGHTEN.

Defective pressure release valve.

Defective check valve.

Air leaks at pressure switch re-
lease valve.

Remove and replace the release valve.

DO NOT DRILL INTO, WELD OR OTHERWISE
MODIFY AIR TANK OR IT WILL WEAKEN.
THE TANK CAN RUPTURE OR EXPLODE.

TROUBLESHOOTING  GUIDE

PERFORMING REPAIRS MAY EXPOSE VOLTAGE SOURCES, MOVING PARTS OR COMPRESSED
AIR SOURCES.  PERSONAL INJURY MAY OCCUR.  PRIOR TO ATTEMPTING ANY REPAIRS,
UNPLUG THE COMPRESSOR AND BLEED OFF TANK AIR PRESSURE.

CAUSE

Pressure reading on the regu-
lated pressure gauge drops when
an accessory is used.

If there is an excessive amount of pressure drop when
the accessory is used, adjust the regulator following
the instructions on page 7.

NOTE

Air tank must be replaced.  Do not repair the leak.

A defective check valve results in a constant air leak at
the pressure release valve when there is pressure in the
tank and the compressor is shut off.  Remove and clean
or replace check valve.  

DO NOT OVER-TIGHTEN.

Defective or dirty check valve.

Defective air tank.

Air leaks in tank or at air tank welds.

It is normal for “some” pressure drop to
occur.

Adjust the regulated pressure under flow
conditions (while accessory is being  used).

Summary of Contents for FA153

Page 1: ...essor Part number and description of the item you wish to purchase OWNERS MANUAL FOR PERMANENTLY LUBRICATED AIR COMPRESSOR For Home Use Only SAFETY GUIDELINES 1 WARRANTY 2 WARNING CHART 3 4 GLOSSARY 5...

Page 2: ...service call arrangement If the purchaser does not receive satisfactory results from the Authorized Warranty Service Center the purchaser should contact DeVilbiss Air Power Company Merchandise sold a...

Page 3: ...MAKE ANY MODIFICATIONS TO THE TANK or its attachments Never attempt to repair a damaged or leaking tank Replace with a new tank The tank is designed to withstand specific operating pressures NEVER MAK...

Page 4: ...ctly or from a breathing device connected to the compressor WORK IN AN AREA equipped WITH GOOD CROSS VENTILATION Read and FOLLOW THE SAFETY INSTRUCTIONS provided on the label or safety data sheet FOR...

Page 5: ...k pressure drops to approximately 100 PSI the motor will restart automatically The low pressure at 1 Set the ON OFF switch to OFF and unplug the cord 2 Reviewthe OperatingProcedures section page9 Be s...

Page 6: ...will accept the plug on the compressor ingoodcondition no longer than 50 feet 14 gauge AWG or larger Wire size increases as gaugenumberdecreases 12AWG 10AWGand 8 AWG may also be used DO NOT USE 16 OR...

Page 7: ...lt if the followingbreak ininstructionsare notcloselyfollowed The air compressor is equipped with a cord having a grounded wire with an appropriate grounding plug The plug must be used with an outlet...

Page 8: ...F AUTO lever to AUTO and allow tank pressuretobuild Motorwillstopwhentankpressure reaches cut out pressure 4 Opentheregulatorbyturningitclockwise Adjustthe regulator to the correct pressure setting Yo...

Page 9: ...eaks at pressure switch re leasevalve Remove and replace the release valve DO NOT DRILL INTO WELD OR OTHERWISE MODIFY AIR TANK OR IT WILL WEAKEN THE TANK CAN RUPTURE OR EXPLODE TROUBLESHOOTING GUIDE P...

Page 10: ...Tankpressureexceedspressureswitch cut in pressure Check for proper gauge wire and cord length Wrong gauge wire or length of exten sion cord Loose electrical connections Check wiring connection inside...

Page 11: ...ANK DRAIN VALVE Not Shown CHECKVALVE Not Shown ISOLATOR DESCRIPTION PART NUMBER REGULATOR CAC 4296 1 TANK PRESSURE GAUGE C GA 345 OUTLET PRESSURE GUAGE C GA 345 SAFETY VALVE TIA 4150 DRAIN VALVE SS 27...

Page 12: ...ower Company 213 Industrial Drive Jackson TN 38301 9615 WARRANTY This product is covered by the DeVilbiss one year limited warranty The warranty can be found in the General Manual or is available upon...

Reviews: