11 — ENG

MGP-FA752-3A

High discharge pressure.

Cannot be adjusted lower.

Adjustable pressure valve not func-

tioning.

Air Leaks

Hose fitting loose.

Prolonged excessive use of air.

Decrease the amount of air usage.  Your compres-

sor is not large enough for the air requirement.

Tighten fitting.

Compressor is not delivering

enough air.

Replace the hose.

Hole in hose.

Air leaks.

Tighten fittings.

1. Check fuse box for blown fuse and replace as

necesssary.  Reset circuit breaker.  Do not

use a fuse or circuit breaker with higher rating

than that specified for your particular branch

circuit.

2. Check for proper fuse.  You should be using a

Quick Acting fuse.

3. Check for low voltage problem.

4. Check the extension cord.

5. Disconnect the other electrical appliances

from circuit or operate the compressor on its

own branch circuit.

Fuse blown, circuit breaker tripped.

Motor will not run.

Extension cord is wrong length or

gauge.

Check the extension cord.

Loose electrical connections.

Check wiring connection inside terminal box

Faulty motor.

Have checked at a local Service Center.

VOLTAGE SOURCES, MOVING PARTS OR COMPRESSED AIR SOURCES ARE EXPOSED
WHEN REPAIRING THE COMPRESSOR.  PERSONAL INJURY CAN OCCUR.  UNPLUG THE
COMPRESSOR BEFORE ATTEMPTING ANY REPAIRS.

RISK OF BURSTING.  DO NOT OPERATE
THE COMPRESSOR IF THIS PROBLEM
EXISTS.  ADJUSTABLE PRESSURE VALVE
MUST BE REPLACED.

CORRECTION

CAUSE

PRO

BLEM

TROUBLESHOOTING GUIDE

Summary of Contents for FA752-3

Page 1: ...ThisinformationrelatestoprotectingYOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS To help you recognize this information we use the symbols to the right Please read the manual and pay attention to thes...

Page 2: ...ART 4 6 GLOSSARY 7 DUTY CYCLE 7 DESCRIPTIONOFOPERATION 7 INSTALLATIONANDBREAK IN PROCEDURES 8 LocationofAirCompressor 8 ExtensionCords 8 GroundingInstructions 8 AirHose 8 OPERATINGPROCEDURES 9 STORAGE...

Page 3: ...tallationandstart upcost ANY INCIDENTAL INDIRECT OR CONSEQUENTIAL LOSS DAMAGE OR EXPENSE THAT MAY RESULT FROM ANYDEFECT FAILUREORMALFUNCTIONOFTHEPRODUCT Somestates donotallowtheexclusionorlimitation o...

Page 4: ...LOSION OR FIRE AIR TANK THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK AND RESULT IN A VIOLENT TANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJURY DRAIN TANK DAILY OR AFTE...

Page 5: ...PRESSOR EITHER DIRECTLY OR FROM A BREATHING DEVICE CONNECTED TO THE COMPRESSOR WORK IN AN AREA WITH GOOD CROSS VENTILATION READ AND FOLLOW THE SAFETY INSTRUCTIONS PROVIDED ON THE LABEL OR SAFETY DATA...

Page 6: ...PROTECTIVE SHROUDS OR ATTEMPT MAINTENANCE UNTIL UNIT HAS BEEN ALLOWED TO COOL WHAT CAN HAPPEN HOW TO PREVENT IT A PORTABLE COMPRESSOR CAN FALL FROM A TABLE WORKBENCH OR ROOF CAUSING DAMAGE TO THE COM...

Page 7: ...compressor to theaccessory Thepressureadjustingvalvecanbeused to set approximate pressure between 10 and 125 P S I 125 P S I is the highest pressure this compressor will deliver It is normal for the...

Page 8: ...l ventilated area The air compressor pump and case are designed to allow for proper cooling Clean or blow off dust or dirt that collects on the air compressor A clean air compressor runs cooler and pr...

Page 9: ...ceed the maximum pressure rating 6 Slowly increase the pressure setting of the adjustable pressure valve You should be able to hear and feel air pressure being relieved by the adjustable pressure val...

Page 10: ...707 Pressure Valve Assembly CAC 4324 Outlet Tube CAC 1289 Connecting Rod Kit KK 4964 Fastener Kit KK 4929 Isolator Kit K 0387 Nut Sleeve Assy SSP 473 Pipe T SSP 3305 NI Air Chuck SSH 8 PRESSUREVALVE A...

Page 11: ...ouldbeusinga Quick Acting fuse 3 Checkforlowvoltageproblem 4 Check the extension cord 5 Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit Fuse...

Page 12: ...r for ordering repair parts and for warranty repairs When ordering repair parts from your local Authorized Service Center always give the following information Model number of your product Part number...

Reviews: