11 — ENG
TROUBLESHOOTING GUIDE (Continued)
CORRECTION
CAUSE
Remove and clean, or replace.
Air leaks.
Tighten fittings. (See Air Leaks Section of Trou-
bleshooting Guide.)
Motor will not run.
Check valve restricted.
PROBLEM
Motor will start automatically when tank pressure
drops below “cut-in” pressure of pressure switch.
Tank pressure exceeds pressure
switch “cut-in” pressure.
Check for proper gauge wire and cord length.
Wrong gauge wire or length of exten-
sion cord.
Loose electrical connections.
Check wiring connection inside pressure switch
and terminal box area.
Remove and clean, or replace.
Check valve stuck open.
Paint spray on internal motor parts.
Have checked at an Authorized Warranty Service
Center. Do not operate the compressor in the paint
spray area. See flammable vapor warning.
Possible defective motor.
Have checked at an Authorized Warranty Service
Center.
1.
Check fuse box for blown fuse and replace, if
necessary. Reset circuit breaker. Do not use a
fuse or circuit breaker with higher rating than
that specified for your particular branch circuit.
2.
Check for proper fuse.
3.
Check for low voltage conditions and/or proper
extension cord.
4.
Disconnect the other electrical appliances from
circuit or operate the compressor in its own
branch circuit.
Fuse blown, circuit breaker tripped.
Damaged regulator.
Replace regulator.
Regulator knob has continuous
air leak. Regulator will not shut
off at air outlet.
Compressor is not supplying
enough air to operate acces-
sories. (cont'd)