background image

4 — ENG

CONTINUE NEXT PAGE 

*

RISK OF BURSTING

RISK OF

EXPLOSION OR FIRE

RISK OF

ELECTRICAL SHOCK

AIR TANK

THE FOLLOWING CONDITIONS COULD

 LEAD

TO A WEAKENING OF THE TANK, AND 

RESULT

IN A VIOLENT TANK EXPLOSION:

1.

FAILURE TO PROPERLY DRAIN

CONDENSED

  WATER FROM THE TANK,

CAUSING RUST AND THINNING OF THE
STEEL TANK.

2. 

MODIFICATIONS

 OR ATTEMPTED

REPAIRS 

TO THE TANK.

3. UNAUTHORIZED 

MODIFICATIONS TO THE

PRESSURE SWITCH, SAFETY VALVE, OR

ANY 

OTHER COMPONENTS WHICH

CONTROL

 TANK 

PRESSURE.

ATTACHMENTS  & ACCESSORIES

EXCEEDING THE PRESSURE RATING OF AIR
TOOLS,

 SPRAY GUNS, AIR OPERATED ACCES-

SORIES, TIRES AND OTHER INFLATABLES 

CAN

CAUSE THEM TO EXPLODE

 OR FLY APART,

AND COULD RESULT IN SERIOUS INJURY.

IT IS NORMAL FOR ELECTRICAL CONTACTS

WITHIN THE MOTOR AND PRESSURE SWITCH

TO SPARK.

IF

 ELECTRICAL 

SPARKS

 FROM COMPRESSOR

COME INTO CONTACT WITH FLAMMABLE
VAPORS, THEY MAY IGNITE, CAUSING FIRE
OR EXPLOSION.

RESTRICTING

 ANY OF THE 

COMPRESSOR

VENTILATION OPENINGS WILL CAUSE SERI-
OUS OVERHEATING AND COULD CAUSE
FIRE.

YOUR 

AIR COMPRESSOR IS POWERED BY

ELECTRICITY.

  LIKE ANY OTHER ELECTRI-

CALLY POWERED DEVICE, 

IF IT IS NOT USED

PROPERLY IT MAY CAUSE ELECTRIC SHOCK.

DRAIN TANK DAILY OR AFTER EACH USE.

IF TANK DEVELOPS A LEAK, REPLACE IT
IMMEDIATELY WITH A NEW TANK OR NEW
COMPRESSOR OUTFIT.

NEVER

 DRILL INTO, WELD, OR 

MAKE ANY

MODIFICATIONS TO THE TANK

 OR ITS

ATTACHMENTS.

THE TANK IS DESIGNED TO WITHSTAND
SPECIFIC OPERATING PRESSURES.  

NEVER

MAKE ADJUSTMENTS OR PARTS SUBSTI-
TUTIONS TO

 ALTER THE 

FACTORY SET

OPERATING 

PRESSURES.

FOLLOW THE EQUIPMENT MANUFACTUR-
ERS RECOMMENDATION AND NEVER
EXCEED THE MAXIMUM ALLOWABLE PRES-
SURE RATING OF ATTACHMENTS.  

NEVER

USE COMPRESSOR TO INFLATE SMALL
LOW-PRESSURE OBJECTS SUCH AS
CHILDREN’S TOYS, FOOTBALLS,
BASKETBALLS. ETC.

ALWAYS 

OPERATE THE COMPRESSOR IN A

WELL VENTILATED 

AREA FREE OF COM-

BUSTIBLE MATERIALS, GASOLINE OR SOL-
VENT VAPORS.

IF SPRAYING FLAMMABLE MATERIALS, 

LO-

CATE COMPRESSOR AT LEAST 20 FEET
AWAY FROM SPRAY AREA.

  AN ADDITIONAL

LENGTH OF HOSE MAY BE REQUIRED.

STORE FLAMMABLE MATERIALS IN A
SECURE LOCATION AWAY FROM COM-
PRESSOR.

NEVER PLACE OBJECTS AGAINST OR ON
TOP OF COMPRESSOR.  OPERATE COM-
PRESSOR

 IN AN OPEN AREA AT LEAST 

12

INCHES AWAY FROM 

ANY  WALL OR

OBSTRUCTION

 THAT WOULD RESTRICT THE

FLOW OF FRESH AIR TO THE VENTILATION
OPENINGS.

NEVER OPERATE THE COMPRESSOR OUT-
DOORS WHEN IT IS RAINING OR IN WET
CONDITIONS.

NEVER OPERATE COMPRESSOR WITH
COVER

 COMPONENTS 

REMOVED

 OR DAM-

AGED.

HAZARD

WHAT CAN HAPPEN

HOW TO PREVENT IT

•  SAVE THESE INSTRUCTIONS •

IMPORTANT SAFETY INSTRUCTIONS

IMPROPE

R OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS

INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING
INSTRUCTIONS BEFORE USING THIS EQUIPMENT.

Summary of Contents for FAC28-1

Page 1: ...a circuit protected by fuses use quick acting fuses MGP FAC28 1 4 6 98 DeVILBISS AIR POWER COMPANY DeVilbiss Air Power Company 213 Industrial Dr Jackson TN 38301 9615 SAFETY GUIDELINES DEFINITIONS IM...

Page 2: ...of Air Compressor 7 INSTALLATION AND BREAK IN PROCEDURES 7 8 Location of Air Compressor 7 Page Extension Cords 7 Voltage and Circuit Protection 7 Grounding Instructions 8 Additional Regulators and Co...

Page 3: ...service call arrangement If the purchaser does not receive satisfactory results from the Authorized Warranty Service Center the purchaser should contact DeVilbiss Air Power Company Merchandise sold a...

Page 4: ...MPRESSOR OUTFIT NEVER DRILL INTO WELD OR MAKE ANY MODIFICATIONS TO THE TANK OR ITS ATTACHMENTS THE TANK IS DESIGNED TO WITHSTAND SPECIFIC OPERATING PRESSURES NEVER MAKE ADJUSTMENTS OR PARTS SUBSTI TUT...

Page 5: ...Y ELECTRICAL WIRING OR REPAIRS REQUIRE ON THIS PRODUCT SHOULD BE PERFORMED BY AUTHORIZED SERVICE CENTER PERSONNEL IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES MAKE CERTAIN THAT THE ELECTRICA...

Page 6: ...restart automatically The low pressure at which the motor automatically re starts is called cut in pressure 1 Set the ON OFF switch to OFF and unplug the cord 2 Reviewthe OperatingProcedures section p...

Page 7: ...d a 3 slot receptacle that will accept the plug on the compressor ingoodcondition no longer than 50 feet 14 gauge AWG or larger Wire size increases as gaugenumberdecreases 12AWG 10AWGand 8 AWG may als...

Page 8: ...t if the followingbreak ininstructionsare notcloselyfollowed The air compressor is equipped with a cord having a grounded wire with an appropriate grounding plug The plug must be used with an outlet t...

Page 9: ...OFF AUTO lever to AUTO and allow tank pressuretobuild Motorwillstopwhentankpressure reaches cut out pressure 4 Opentheregulatorbyturningitclockwise Adjustthe regulator to the correct pressure setting...

Page 10: ...e heard escaping Check fittings with soapy water solution DO NOT OVER TIGHTEN Air leaks in air tank or at air tank welds DO NOT DRILL INTO WELD OR OTHERWISE MODIFY AIR TANK OR IT WILL WEAKEN THE TANK...

Page 11: ...arts Have checked at an Authorized Warranty Service Center Do not operate the compressor in the paint spray area See flammable vapor warning Possible defective motor Have checked at an Authorized Warr...

Page 12: ...SSP 490 CAC 1254 KEY NO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DESCRIPTION Safety Valve Drain Valve Wheel 6 2 used Shoulder Bolt 2 used Nut Hex 3 8 16 UNC 2B 2 used Handle Screw 10 16 x 1...

Page 13: ...13 ENG PUMP DIAGRAM...

Page 14: ...ket Valve plate assembly O ring OutletTube Rod assembly Screw 3 8 16 x 1 25 LG hex socket flat head Cylinder sleeve Motor Endbellassembly Timingbelt Pumpisolator Shroud right Shroud left Screw 10 9 x...

Page 15: ...15 ENG SERVICE NOTES...

Page 16: ...location of the nearest Authorized Service Center for ordering repair parts and for warranty repairs When ordering repair parts from your local Authorized Service Center always give the following inf...