4 — ENG

HAZARD

RISK OF

ELECTRICAL SHOCK

RISK FROM

FLYING OBJECTS

RISK TO BREATHING

RISK FROM

MOVING PARTS

RISK OF BURNS

WHAT CAN HAPPEN

YOUR 

AIR COMPRESSOR IS POWERED BY

ELECTRICITY.

  LIKE ANY OTHER ELECTRI-

CALLY POWERED DEVICE, 

IF IT IS NOT USED

PROPERLY IT MAY CAUSE ELECTRIC SHOCK.

REPAIRS ATTEMPTED BY UNQUALIFIED
PERSONNEL CAN RESULT IN SERIOUS
INJURY OR DEATH BY ELECTROCUTION.

ELECTRICAL GROUNDING:  

FAILURE TO

PROVIDE ADEQUATE GROUNDING TO THIS
PRODUCT COULD RESULT IN SERIOUS
INJURY OR DEATH FROM ELECTROCUTION.

SEE GROUNDING INSTRUCTIONS.

THE 

COMPRESSED AIR

 STREAM 

CAN CAUSE

SOFT TISSUE DAMAGE

 TO EXPOSED SKIN

AND CAN PROPEL

 DIRT, CHIPS, 

LOOSE

PARTICLES

 AND SMALL OBJECTS AT 

HIGH

SPEED

, RESULTING IN PROPERTY DAMAGE

OR PERSONAL INJURY.

THE 

COMPRESSED AIR

 FROM YOUR COM-

PRESSOR 

IS NOT SAFE FOR BREATHING!

THE AIR STREAM MAY CONTAIN CARBON
MONOXIDE, TOXIC VAPORS OR SOLID PAR-
TICLES.

SPRAYED MATERIALS

 SUCH AS PAINT, PAINT

SOLVENTS, PAINT REMOVER, INSECTICIDES,
WEED KILLERS, ETC.. 

CONTAIN HARMFUL

VAPORS

 AND POISONS.

THE 

COMPRESSOR CYCLES AUTOMATI-

CALLY WHEN

 THE

  PRESSURE SWITCH IS IN

THE ON/AUTO POSITION.

MOVING PARTS CAN CAUSE SERIOUS
INJURY

 OR DAMAGE IF THEY COME INTO

CONTACT WITH YOU OR YOUR CLOTHING.

ATTEMPTING TO OPERATE OR REPAIR
COMPRESSOR WITH PROTECTIVE SHROUDS
REMOVED CAN EXPOSE YOU TO MOVING
PARTS AND ELECTRICAL SHOCK.

TOUCHING EXPOSED 

METAL SUCH AS THE

COMPRESSOR HEAD OR OUTLET TUBE 

CAN

RESULT IN SERIOUS BURNS.

HOW TO PREVENT IT

NEVER OPERATE THE COMPRESSOR OUT-
DOORS WHEN IT IS RAINING OR IN WET
CONDITIONS.

NEVER OPERATE COMPRESSOR WITH
COVER

 COMPONENTS 

REMOVED

 OR DAM-

AGE.

ANY 

ELECTRICAL WIRING OR REPAIRS

REQUIRED ON THIS PRODUCT 

SHOULD BE

PERFORMED BY AUTHORIZED SERVICE
CENTER PERSONNEL

 IN ACCORDANCE WITH

NATIONAL AND LOCAL ELECTRICAL CODES.

MAKE CERTAIN THAT

 THE 

ELECTRICAL

CIRCUIT

 TO WHICH THE COMPRESSOR IS

CONNECTED 

PROVIDES PROPER ELECTRI-

CAL GROUNDING, CORRECT VOLTAGE AND
ADEQUATE FUSE PROTECTION.

ALWAYS WEAR ANSI Z87.1 APPROVED
SAFETY GLASSES WITH SIDE SHIELDS

 WHEN

USING THE COMPRESSOR.

NEVER POINT ANY NOZZLE OR SPRAYER
TOWARD ANY PART OF THE BODY OR AT
OTHER PEOPLE OR ANIMALS.

ALWAYS 

TURN OFF

 THE 

COMPRESSOR,

BLEED PRESSURE FROM THE AIR HOSE 

AND

TANK, AND DISCONNECT FROM POWER
SOURCE 

BEFORE PERFORMING MAINTE-

NANCE OR ATTACHING TOOLS AND ACCES-
SORIES.

NEVER INHALE AIR FROM THE COMPRES-
SOR

 EITHER DIRECTLY OR FROM A BREATH-

ING DEVICE CONNECTED TO THE COMPRES-
SOR.

WORK IN AN AREA WITH GOOD CROSS-
VENTILATION.

 READ AND 

FOLLOW THE

SAFETY INSTRUCTIONS

 PROVIDED ON THE

LABEL OR SAFETY DATA SHEETS 

FOR THE

MATERIAL YOU ARE SPRAYING.  

   

USE A

NIOSH/MSHA APPROVED RESPIRATOR

 DE-

SIGNED FOR USE WITH YOUR SPECIFIC
APPLICATION.

ALWAYS 

TURN OFF

 THE 

COMPRESSOR,

BLEED PRESSURE FROM THE AIR HOSE 

AND

TANK, AND DISCONNECT FROM POWER
SOURCE 

BEFORE PERFORMING MAINTE-

NANCE OR ATTACHING TOOLS AND ACCES-
SORIES.

DO NOT REMOVE THE PROTECTIVE COVERS

FROM THIS PRODUCT.  

NEVER OPERATE

 THE

COMPRESSOR WITH GUARDS

 OR COVERS

WHICH ARE DAMAGED OR 

REMOVED.

ANY 

REPAIRS

 REQUIRED ON THIS 

PRODUCT

SHOULD BE PERFORMED BY AUTHORIZED
SERVICE CENTER PERSONNEL.

NEVER TOUCH ANY EXPOSED METAL PARTS
ON COMPRESSOR

 DURING OR IMMEDIATELY

AFTER OPERATION.  

COMPRESSOR WILL

REMAIN HOT

 FOR SEVERAL MINUTES AFTER

OPERATION.

DO NOT REACH AROUND PROTECTIVE
SHROUDS OR ATTEMPT MAINTENANCE UNTIL
UNIT HAS BEEN ALLOWED TO COOL.

SCWORPOL — 7/23/97

Summary of Contents for FTV560V

Page 1: ...s situation which if not avoided could result in death of serious injury CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION used wi...

Page 2: ...TION AND BREAK IN INSTALLATION AND BREAK IN INSTALLATION AND BREAK IN INSTALLATION AND BREAK IN PROCEDURES PROCEDURES PROCEDURES PROCEDURES PROCEDURES 6 8 Removal of Shipping Boards and Installation 6...

Page 3: ...ATTACHMENTS THE TANK IS DESIGNED TO WITHSTAND SPECIFIC OPERATING PRESSURES NEVER MAKE ADJUSTMENTS OR PARTS SUBSTI TUTIONS TO ALTER THE FACTORY SET OPERATING PRESSURES FOR ESSENTIAL CONTROL OF AIR PRES...

Page 4: ...MPONENTS REMOVED OR DAM AGE ANY ELECTRICAL WIRING OR REPAIRS REQUIRED ON THIS PRODUCT SHOULD BE PERFORMED BY AUTHORIZED SERVICE CENTER PERSONNEL IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES...

Page 5: ...ical Engineers made tested inspected and registered to meet the standards of ASME California Code Unit may comply with California Code 462 L 2 M 2 Specification model label is on the side of the tank...

Page 6: ...ing ON AUTO OFF Switch ON AUTO OFF Switch ON AUTO OFF Switch ON AUTO OFF Switch ON AUTO OFF Switch Turn this switch ON to provide automatic power to the pressure switch and OFF to remove power at the...

Page 7: ...r that is the same rating as the branch circuit the air compressor is operated on If the compressor is connected to a circuit protected by fuses use only dual element time delay fuses Piping INST INST...

Page 8: ...ve is closed 2 Attach hose and accessories TOO MUCH AIR PRESSURE CAUSES A HAZARD OUSRISKOFBURSTING CHECKTHEMANUFAC TURER S MAXIMUM PRESSURE RATING FOR AIR TOOLS AND ACCESSORIES THE REGULATOR OUTLET PR...

Page 9: ...MUST BE REPLACED WITH THE SAME TYPE OF MUST BE REPLACED WITH THE SAME TYPE OF MUST BE REPLACED WITH THE SAME TYPE OF VALVE VALVE VALVE VALVE VALVE Motor The motor has an automatic reset thermal overlo...

Page 10: ...TAGE SOURCES MOVING PARTS OR COMPRESSED AIR SOURCES PERSONALINJURYMAYOCCUR PRIORTOATTEMPTINGANYREPAIRS DISCONNECTPOWERSOURCEFROMTHE COMPRESSOR AND BLEED OFF TANK AIR PRESSURE CORRECTION Pressure switc...

Page 11: ...connection inside pressure switch and terminal box area Inspect or replace if necessary Inspect or replace if necessary Do not operate the compressor in the paint spray area See flammable vapor warni...

Page 12: ...Intake Muffler FilterElement Screw 10 14 x 2 5 Pan Head 2 used OutletTube Crossover Tube Nut Sleeve Assy Nut Brass Compression 3 used Silicone Sleeve 3 used Check Valve Connector Body Nut Sleeve Assy...

Page 13: ...1 25 8 used Torque 7 10 ft lbs 13 ACG 11 Muffler Intake 2 used 14 ACG 8 Pin Eccentric 15 ACG 6 Counter Balance Inner 16 ACG 9 Washer 17 ACG 7 Counter Balance Outer 18 ACG 23 Nut Torque 85 100 ft lbs...

Page 14: ...l or is available upon request Call our Toll Free Number 1 800 888 2468 Ext 2 then Ext 1 to obtain the location of the nearest Authorized Service Center for ordering repair parts and for warranty repa...