background image

 

 

 

 

 

 

JUPITER-K GUN

 

Operation Manual 

For GENERAL INDUSTRIES 

IMPORTANT

Read and follow all instructions and SAFETY PRECAUTIONS 

before using this equipment. 

The gun body of this model is finished with special coating.    Do not use wire-brush or metal-spatula 
for cleaning.    Do not inscribe letters on the gun body.    It may cause the coating to peel off. 

 

MODELS 

JUPITER-K

 

 

Air Cap 

 

 

Fluid Tip Size

 

 

Type of Feed 

P

Pressure

 

 

(Ex.)

  JUPITER

-

K

P1

FX

P

  

  (

P1 Air Cap

 

 

Size

 

FX (1.1mm)

 

 

Pressure) 

 

SPECIFICATIONS 

Maximum Working Air Pressure

  0.69 MPa,    Maximum Working Fluid Pressure

  0.69 MPa 

Chart.1 

Air cap 

 

Part Number 

Tip Size

mm

 

Type 

Air 

Consumption 

Air Inlet 

Pressure 

Pattern 

Range 

(mm) 

Applications 

Fluid Inlet 

Air Inlet 

Weight 

(g) 

FX(1.1

 

FF(1.4) 

P1 

JUP-3-P1 

 

 

Pressure 

LVMP 

200L/min 

0.2MPa 

250mm 

Automotives & 

General Industries 

G3/8 

G1/4 

348g 

P2 

JUP-3-P2 

 

 

Pressure 

LVMP 

200L/min 

0.2MPa 

300mm 

P3 

JUP-3-P3 

 

 

Pressure 

Conventional 

550L/min 

0.24MPa 

400mm 

 

PARTS LIST 

 
Chart.2

 

 

 
Chart.3 

 
 

 

Ref. 

 

Part Number 

Description 

Qty 

1  JUP-6 

Retaining Ring 

2  JUP-50-K5 

Cap Seat 

3  JUP-55-K5 

Ring Seat 

4  Refer Chart.1 

Air Cap 

5  Refer Chart.3 

Fluid Tip 

6  JUP-7 

Baffle 

7  JUP-8-K5 

Gasket 

8  SN-404-K 

Packing, Spring & Packing Nut Kit 

9  JUP-12 

Body Bushing & Seal 

10  JUP-72-K5 

Body Bushing Gasket 

11  Refer Chart 3 

Needle 

12  SN-409 

Valve Spring and Pad Kit 

13  JUP-13-K 

Needle Adjusting Knob 

14  JUP-44-K 

Pattern Valve Assembly 

15  JUP-43 

Air Valve Assembly 

16  SN-405-J-K5 

Trigger Stud & Hex Screw 

17  JUP-108 

Trigger 

18  JUP-21 

Plug 

19  JUP-30 

Air Connector 

20  SN-26-K4 

Color ID Ring Kit (sold separately) 

21  JUP-35P 

Fluid Inlet (Pressure) 

   

 

 

Description   

Size 

mm

 

Fluid Tip 

Needle   

FX(1.1) 

JUP-4-FX-S 

JUP-41-FZ 

FF(1.4) 

JUP-4-FF-S 

JUP-41-FZ 

 

Summary of Contents for JUPITER-K

Page 1: ...n 0 2MPa 250mm Automotives General Industries G3 8 G1 4 348g P2 JUP 3 P2 Pressure LVMP 200L min 0 2MPa 300mm P3 JUP 3 P3 Pressure Conventional 550L min 0 24MPa 400mm PARTS LIST Chart 2 Chart 3 Ref Part Number Description Qty 1 JUP 6 Retaining Ring 1 2 JUP 50 K5 Cap Seat 1 3 JUP 55 K5 Ring Seat 1 4 Refer Chart 1 Air Cap 1 5 Refer Chart 3 Fluid Tip 1 6 JUP 7 Baffle 1 7 JUP 8 K5 Gasket 1 8 SN 404 K P...

Page 2: ...ds may injure eyes Do not point the spray gun to any person 3 Gravity or suction feed gun must not be used for pressure feed gun 4 Parts with compressed air may damage the human body Connect air hoses tightly by using a spanner so that air never leaks If tightened loosely hoses can be removed which may result in damaging the human body objects to be coated and other equipment used together 5 Parts...

Page 3: ...terclockwise 3 Remove Adjusting Screw 13 and Needle Spring 12 and then withdraw Needle 11 from the gun body 4 Remove Retaining Ring 1 and Air Cap 4 5 Remove Fluid Tip 5 by using socket wrench or offset wrench and Baffle 6 can also be removed 6 Recommended torque of Fluid Tip 5 is 8N m Fluid Inlet 21 and Air Connector 19 Fluid Inlet 21 and Air Connector 19 are fixed together by sealing material Do ...

Page 4: ...ose or damaged Fluid Tip 5 Fill cup or tighten the Connector Clean Replace Tighten or replace Fluid leaking from Needle Packing Nut 8 Worn or damaged Needle Packing 8 Replace Dripping from Fluid Tip Worn or damaged Fluid Tip 5 or Needle 11 Stuck Needle Packing 8 or Needle 11 Loose Adjusting Screw 13 Replace Lubricate Adjust ACCESSORIES Part Description Part Description 42884 214 K5 Cleaning Brush ...

Reviews: