background image

14- ENG

A03203

How to Start:

1.

Turn the Off/Auto switch to
"AUTO" and allow tank pressure
to build.  Motor will stop when
tank pressure reaches "cut-out"
pressure.

2.

Turn the regulator knob
clockwise until desired pressure
is reached. The compressor is
ready for use.

Before Each Start-Up:

1.

Place Off/Auto switch  to "OFF"
and close air regulator.

2.

Turn the regulator knob
counterclockwise until it stops.

3.

Attach hose and accessories.

Risk of Bursting.

Too much air

pressure causes a hazardous risk
of bursting. Check the
manufacturer’s maximum pressure
rating for air tools and accessories.
The regulator outlet pressure must
never exceed the maximum
pressure rating.

Summary of Contents for ProAir II P1015

Page 1: ...A03203 5 25 04 ESPA OL 21 40 Questions 1 800 888 2468 READ AND SAVE THESE INSTRUCTIONS Owner s Manual For Model P1015 Home Hobby Air Compressor...

Page 2: ...Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to the State of California to cause cancer birth defects or other reproductive ha...

Page 3: ...r property damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent...

Page 4: ...lace the entire compressor Failure to properly drain condensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to...

Page 5: ...ect voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the...

Page 6: ...thing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate...

Page 7: ...Do not operate the product when fatigued or under the influence of alcohol or drugs Stay alert at all times Never defeat the safety features of this product Equip area of operation with a fire extingu...

Page 8: ...pump should not run more than 30 45 minutes in any given hour When the tank pressure drops to a certain low level the motor will restart automatically The low pressure at which the motor automaticall...

Page 9: ...or Accessory Kit Assemble Other Accessories 1 Attach the hose adapter to hose 2 Choose the needed accessory Attach the tapered nozzle extension tube or blow gun adapter to the hose adapter The inflati...

Page 10: ...t or plug MUST be made by a qualified electrician INSTALLATION GROUNDING INSTRUCTIONS Risk of Electrical Shock In the event of a short circuit grounding reduces the risk of shock by providing an escap...

Page 11: ...essors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply to circuit must comply with the National Electrical Code 2 Circuit is not used to supply any other elect...

Page 12: ...power to the pressure switch and OFF to shut off power at the end of each use Pressure Switch not shown The pressure switch automatically starts the motor when the air tank pressure drops below the f...

Page 13: ...mpressor has raised the air tank pressure above that required at the air outlet Check Valve not shown When the air compressor is operating the check valve is open allowing compressed air to enter the...

Page 14: ...The compressor is ready for use Before Each Start Up 1 Place Off Auto switch to OFF and close air regulator 2 Turn the regulator knob counterclockwise until it stops 3 Attach hose and accessories Risk...

Page 15: ...on When performing maintenance you may be exposed to voltage sources compressed air or moving parts Personal injuries can occur Before performing any maintenance or repair disconnect power source fro...

Page 16: ...in the air tank If not drained water will corrode and weaken the air tank causing a risk of air tank rupture 2 Store accessories in the storage bag located on back of unit The storage bag has a smalle...

Page 17: ...EM CAUSE CORRECTION Pressure switch does not shut off motor when compressor reaches cut out pressure Pressure switch cut out too high Move Off Auto switch to the OFF position if the unit does not shut...

Page 18: ...box for blown fuse and replace as necessary Reset circuit breaker Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit Check for proper fuse Y...

Page 19: ...19 ENG A03203 REPAIR PARTS 1 2 Key No Part No Description 1 Z D30180 Rubber Bumper Kit includes 4 2 Z D29379 Storage Bag Kit...

Page 20: ...s If the purchaser does not receive satisfactory results from the Authorized Warranty Service Center the purchaser should contact DeVilbiss Air Power Company THIS WARRANTY DOES NOT COVER Merchandise s...

Page 21: ...de lijado aserrado amolado perforado u otras actividades de la construcci n contienen materiales qu micos conocidos en el Estado de California como causantes de c ncer defectos de nacimiento u otros d...

Page 22: ...ra reducir el riesgo de incendio no permita que el compresor opere desatendido Mant ngase siempre alerta cada vez que el producto este funcionando Siempre desconecte del suministro el ctrico colocando...

Page 23: ...las herramientas neum ticas pistolas rociadoras accesorios activados por aire cubiertas y otros objetos inflables puede causar su explosi n o ser arrojados pudiendo ocasionar serias lesiones PELIGRO A...

Page 24: ...n requerida por este producto debe ser efectuada por personal autorizado de los servicentros de acuerdo a los c digos el ctricos nacionales y locales Aseg rese que el circuito el ctrico al cual est co...

Page 25: ...PELIGRO ADVERTENCIA Riesgo de Ca da Un compresor port til puede caerse de la mesa el banco de trabajo o del techo da ando al compresor y pudiendo resultar en serias lesiones o la muerte del operador...

Page 26: ...Mantenga libre la zona de operaciones de persona alguna animales dom sticos y obst culos Mantenga alejados a los ni os del compresor de aire en todo momento No opere el producto cuando se encuentre f...

Page 27: ...la certificaci n de la seguridad GLOSARIO CICLO DE SERVICIO Esta bomba compresora de aire es capaz de funcionar continuamente sin embargo para prolongar la vida til de su compresor de aire se recomien...

Page 28: ...s 1 Instale el adaptador en la manguera 2 Seleccione el accesorio necesario Instale la boquilla c nica el tubo de extensi n o adaptador de pistola sopladora en el adaptador de manguera La boquilla tip...

Page 29: ...do un conductor de escape para la corriente el ctrica Este compresor de aire debe estar adecuadamente conectado a tierra El compresor port til de aire est equipado con un cable que tiene un conductor...

Page 30: ...ircuito de 15 A siempre que se cumplan las siguientes condiciones 1 Que el voltaje suministrado a trav s de los ramales del circuito sea de 15 A 2 Que el circuito no sea utilizado para alimentar ningu...

Page 31: ...ara interrumpir la energ a el ctrica al t rmino del uso Interruptor de presi n El interruptor de presi n permite el arranque autom tico del motor cuando la presi n del tanque disminuye por debajo del...

Page 32: ...e trabajo no se encuentra disponible hasta que el compresor haya alcanzado a llenar el tanque hasta un nivel de presi n por encima del requerido para la salida del aire V lvula reguladora no mostrada...

Page 33: ...uto en la posici n OFF y cierre el regulador de aire 2 Girar la perilla del regulador hasta que se detenga 3 Conecte la manguera y accesorios NOTA Tanto la manguera como los accesorios requerir n un e...

Page 34: ...el operador puede quedar expuesto a fuentes de corriente y de aire comprimido o a piezas movibles Antes de intentar hacer reparaciones desconectar el compresor del tomacorriente drenar la presi n de a...

Page 35: ...i n de agua Si no drena el agua lo corroer y debilitar causando un riesgo de ruptura del tanque de aire 2 Guarde los accesorios en la bolsa en la parte posterior de la unidad La bolsa tiene un bolsill...

Page 36: ...corte El interruptor de presi n de corte esta calibrado demasiado alto Mueva la palanca Off Auto a la posici n OFF si el equipo no corta contacte a un t cnico calificado para el servicio Contacte a un...

Page 37: ...circuito disparado Verifique la caja de fusibles observando la existencia de fusibles fundidos y sustit yalos en caso de necesidad Restablezca el interruptor autom tico No use un fusible o interrupto...

Page 38: ...38 SP A03203 LISTA DE PIEZAS 1 2 Clave No No De Pieza Descripci n 1 Z D30180 Juego de Amortiguadores de Caucho incluye 4 2 Z D29379 Juego de Bolsa para Guardar...

Page 39: ...39 SP A03203 NOTES NOTAS...

Page 40: ...de servicio para efectuar los arreglos para la prestaci n de dicho servicio Si el comprador no obtuviese un resultado satisfactorio de parte del servicentro autorizado para atenci n de garant as deber...