background image

Page 2     SB-2-610-F

ATTENTION!

READ BEFORE ATTACHING THE AIR HOSE

HVLP AIR SUPPLY REQUIREMENTS

FULL SIZE GUN: 

30 PSI inlet pressure provides 10 PSI at the air cap. Consumes 13 CFM.

TOUCHUP GUN: 

30 PSI inlet pressure provides 10 PSI at the air cap. Consumes 8 CFM.

NOTE: USE 5/16" OR LARGER I.D. AIR HOSES

4. If desired, attach air adjust-

ing valve with gauge and/

or quick disconnect to air  

inlet, then attach hose.

5. Spray test and adjust air 

pressure, fan size, and 

fluid flow as required.  

R e c o m m e n d e d   s p r a y 

 

distance is 6-8 inches.  

SET-UP AND ADjUSTMENT INSTRUCTIONS

1. Attach cup to gun and  

flush solvent through gun 

to remove oils.

2. Tighten packing nut—see 

instructions.

3.  Fully open fan and fluid 

needle controls (turn 

counter-clockwise).

Before using this spray gun, 

the packing nut should be  

adjusted as follows:
1. Tighten packing nut until 

fluid needle starts to bind  

in the packing.

2. Loosen packing nut just 

enough so the fluid needle 

moves freely.

PACkING ADjUSTMENT INSTRUCTIONS

AIR CAP

PACKING 

NUT

FLUID NEEDLE

FAN CONTROL

FLUID NEEDLE CONTROL

The packing nut is intentionally left loose so the Teflon packing 

does not take a "set" before the spray gun is used. This allows 

full utilization of the packing.

A failure resulting in injury or damage may be caused by pressure 

beyond top of scale, excessive vibration or pressure pulsation, exces-

sive instrument temperature, corrosion of the pressure containing 

parts or other misuse of the air adjusting valve with gauge.

A

C

B

D

Spray a test area. Turn the fluid needle 

adjusting knob counterclockwise until a 

full coat is obtained.

If the finish is too sandy and dry, the  

material flow may be too low for the  

atomization air pressure being used.  

Turn the fluid needle adjusting knob  

counterclockwise to increase fluid flow.

If  the finish sags, there is too much mate-

rial flowing for the atomization air pressure 

being used. Turn the fluid needle adjusting 

knob clockwise to decrease fluid flow.

Pattern width can be altered by turn-

ing spreader adjustment valve, either  

clockwise to decrease the width or coun-

terclockwise to increase the width.

Adjust inlet air pressure to provide a uni-

form dispersion of atomized paint through-

out the pattern. Keep air pressure as low 

as possible to minimize bounce-back and 

overspray. Excessive pressure will result in 

split spray patterns. Inadequate pressures 

will cause heavy centered patterns and 

poor atomization.

CLEANING

For routine cleaning, it is not necessary 

to remove cup from gun. Remove lid and 

properly dispose of any excess paint. Pour 

in a small amount of clean solvent. The 

amount will vary with different coatings and 

solvents. Reinstall lid. Shake cup to wash 

down the inside  surfaces. Pull trigger to 

allow some solvent to be flushed through 

gun. Remove lid and pour out dirty solvent. 

Add a small amount of clean solvent and 

repeat procedure. Wipe exterior of lid with 

a clean cloth and clean solvent.

If a paint filter was used in the bottom of 

the cup outlet, it should be removed and 

cleaned at this time.

To clean air cap and fluid tip, brush exte-

rior with a stiff bristle brush. If necessary 

to clean cap holes, use a broom straw 

or toothpick if possible. If a wire or hard 

instrument is used, extreme care must 

be used to prevent scratching or burring 

of the holes which will cause a distorted 

spray pattern.

To clean fluid passages, remove excess 

material at source, then flush with a suit-

able solvent. Wipe gun exterior with a 

solvent dampened cloth. Never completely 

immerse in solvent as this is detrimental 

to the lubricants and packings.

PREVENTIVE MAINTENANCE

Spray Gun Lubrication
Apply a drop of SSL-10 spray gun lube at 

trigger bearing stud and the stem of the air 

valve. The shank of the fluid needle where 

it enters the packing nut  should also be 

oiled. The fluid needle packing should be 

kept soft and pliable by periodic lubrication. 

Make sure the baffle and retaining ring 

threads are clean and free of foreign matter. 

Before assembling retaining ring to baffle, 

clean the threads thoroughly, then add two 

drops of SSL-10 spray gun lube to threads. 

The fluid needle spring and air valve spring  

should be coated with a very light grease, 

making sure that any excess grease will 

not clog the air passages. For best results, 

lubricate the points indicated, daily.  

A.  Trigger Points

B. Packing

C.  Adjusting Valve

D.  Baffle/Air Cap Threads

 Fluid Tip
 Size  (mm)  Applications

 

1.0 

General purpose, light to medium

 

 

viscosity material.

 

1.3 

Top coats.

 

1.5 

Top coats and primer sealers.

 1.8  Primers.

Summary of Contents for StartingLine SB-2-610-E

Page 1: ...ATTENTION READ BEFORE ATTACHING THE AIR HOSE HVLP AIR SUPPLY REQUIREMENTS FULL SIZE GUN 30 PSI inlet pressure provides 10 PSI at the air cap Consumes 13 CFM TOUCHUP GUN 30 PSI inlet pressure provides...

Page 2: ...ni formdispersionofatomizedpaintthrough out the pattern Keep air pressure as low as possible to minimize bounce back and overspray Excessivepressurewillresultin split spray patterns Inadequate pressur...

Page 3: ...able vapors Smoking must never be allowed in the spray area Fire extinguishing equipment must be present in the spray area Wear eye protection Follow the requirements of the Material Safety Data Sheet...

Page 4: ...ima del tope de la balanza vibraci n excesiva o pulsaci n de presi n temperatura excesiva del instrumento corrosi n de las piezas que contienen presi n u otro uso indebido de la v lvula de ajuste de a...

Page 5: ...vapores inflamables Nunca debe permitirse fumar en el rea de pulverizaci n Equipo de extinci n de incendio debe estar presente en el rea de pulverizaci n Use protecci n para los ojos Siga los requisi...

Page 6: ...r lesconduitesd air Pourobtenirdemeilleursr sultats lubrifiez les endroits indiqu s tous les jours A Pointes de d tente B Garniture d tanch it C Soupape de r glage D Filetage de l anneau d flecteur Re...

Page 7: ...pulv risation Du mat riel d extinction d incendies doit se trouver pr s de l endroit o se fait la pulv risation Portez des lunettes de protection Suivez les recommandations de s curit de la fiche tec...

Page 8: ...KET 09 O RING 10 HOUSING 11 PAINT NEEDLE 12 SPRING 13 KNOB FLUID CONTROL 14 GASKET 15 SCREW 16 17 VALVE STEM COMPLETE 18 SPRING Ref Part No Description 19 O RING 20 AIR VALVE NUT 21 E RING 2 pcs 22 WA...