TABLE OF CONTENTS

Setup

Therapy Setup

Gradient Mode

Pressure Mode

Lock/Unlock Device

Treatment

03

04

05

08

11-12

13

02

Summary of Contents for CircuFlow 5200

Page 1: ...CircuFlow 5200 Quick Setup Guide www devonmedicalproducts com 1100 First Avenue Suite 202 King of Prussia PA 19406 866 446 0092 LB014 Rev B DRAFT 20121002...

Page 2: ...onmedicalproducts com 1100 First Avenue Suite 202 King of Prussia PA 19406 866 446 0092 TABLE OF CONTENTS Setup Therapy Setup Gradient Mode Pressure Mode Lock Unlock Device Treatment 03 04 05 08 11 12...

Page 3: ...re the box also contains 1 power cord 1 air blocker and a user manual Remove the protective foam covers on each side and the plastic bag Not Pictured Place the device on a at and stable surface near t...

Page 4: ...ower indicator on the front panel will then illuminate Upon this display User can directly push START to run the device on FACTORY DEFAULT mode If GRADIENT MODE is desired continue to steps 10 29 If P...

Page 5: ...h the SHUTTLE KNOB to access GRADIENT MODE It will take you through various parameters PRESSURE GRADIENT TREATMENT TIME CYCLE TIME AND SKIP CHAMBER This display shows the rst parameter PRESSURE turn t...

Page 6: ...to con rm the new gradient Access the third parameter TREATMENT TIME by turning the SHUTTLE KNOB to the right Push the SHUTTLE KNOB to select TREATMENT TIME You can increase the treatment time by tur...

Page 7: ...you wish to skip by turning the SHUTTLE KNOB to the right or left Select one only Chamber 1 Chamber 2 Chamber 3 Chamber 4 or No skip Note Skipping a chamber does not mean the chamber selected will not...

Page 8: ...RESSURE TREATMENT TIME CYCLE TIME AND SKIP CHAMBER This display shows the rst parameter PRESSURE SET Push the SHUTTLE KNOB to select PRESSURE SET then push the SHUTTLE KNOB on the individual chamber y...

Page 9: ...decrease time by turning to the left treatment time can range from 15 180 minutes increments of 15 minutes Push the SHUTTLE KNOB to con rm the new treatment time Access the third parameter CYCLE TIME...

Page 10: ...3 Chamber 4 or No skip Note Skipping a chamber does not mean the chamber selected to skip will not fill with air but less air Push the SHUTTLE KNOB to con rm the skipped chamber To exit and complete...

Page 11: ...currently selected After setting device to desired treatment turn the SHUTTLE KNOB to the right to select Lock De vice Then push the SHUTTLE KNOB to access Lock Device A second screen will appear to...

Page 12: ...nput Password Turn the SHUTTLE KNOB to select the rst char acter of the password press down and select the second character Press down the SHUTTLE KNOB a second time to input the password If the passw...

Page 13: ...off at After the treatment the device will vacuum air from the garment for 1 minute so that it will facili tate removal of the garment Not Pictured Note If using one of the larger size sleeves all the...

Page 14: ...www devonmedicalproducts com 1100 First Avenue Suite 202 King of Prussia PA 19406 866 446 0092 NOTES...

Page 15: ...www devonmedicalproducts com 1100 First Avenue Suite 202 King of Prussia PA 19406 866 446 0092 NOTES...

Page 16: ......