ENGLISH
25
DEMOLITION HAMMER
D25899, D25902, D25941
Congratulations!
You have chosen a D
E
WALT power tool. Years of experience, thorough product development and innovation
make D
E
WALT one of the most reliable partners for professional power tool users.
Technical Data
D25899
D25902
D25941
Voltage V
230
230
230
U.K. & Ireland only
V
230 or 115
230 or 115
230 or 115
Type
1
1
1
Frequency Hz
50
50
50
Power input
W
1,500
1,550
1,600
Impact rate
min
-1
2,040
1,050–2,100
1,620
Impact energy (EPTA 05/2009)
J
17.5
19
22.5
Tool holder
SDS Max
®
SDS
Max
®
19 mm Hex
Chisel positions
12
12
12
Weight kg
9.9
10.5
13.8
D25899 D25899 D25902 D25902 D25941 D25941
(230 V)
(115 V)
(230 V)
(115 V)
(230 V)
(115 V)
L
PA
(sound
pressure)
dB(A)
86
86
89
89
91
91
K
PA
(sound pressure uncertainty)
dB(A)
3
3
3
3
3
3
L
WA
(sound
power)
dB(A)
100
100
100
100
102
102
K
WA
(sound pressure uncertainty)
dB(A)
3
3
3
3
3
3
Vibration total values (triax vector sum) determined according to EN 60745:
Chiselling
Vibration emission value a
h,Cheq
=
m/s²
12 12 7.5 7.5
8.8
8.8
Uncertainty K =
m/s²
1.5 1.5 1.5 1.5 1.5 1.5
The vibration emission level given in this information
sheet has been measured in accordance with a
standardised test given in EN 60745 and may be
used to compare one tool with another. It may be
used for a preliminary assessment of exposure.
WARNING:
The declared vibration
emission level represents the main
applications of the tool. However if the
tool is used for different applications,
with different accessories or poorly
maintained, the vibration emission may
differ. This may significantly increase the
exposure level over the total working
period.
An estimation of the level of exposure to
vibration should also take into account
the times when the tool is switched off
or when it is running but not actually
doing the job. This may significantly
reduce the exposure level over the total
working period.
Identify additional safety measures to
protect the operator from the effects of
vibration such as: maintain the tool and
the accessories, keep the hands warm,
organisation of work patterns.
Fuses:
Europe
230 V tools
10 Amperes, mains
U.K. & Ireland
230 V tools
13 Amperes, in plugs
Summary of Contents for D25899
Page 1: ...D25899 D25902 D25941 ...
Page 3: ...1 Figure 1 D25899 b a d e f q D25902 c b a d e f q D25941 d b e a f q ...
Page 4: ...2 Figure 3 Figure 2 D25899 D25902 Figure 4 D25899 D25902 e ...
Page 5: ...3 Figure 5 D25941 Figure 6 19 mm g h e D25941 ...
Page 6: ...4 Figure 8 f i r d Figure 7 x ...
Page 7: ...5 Figure 9 j k l m n p o ...
Page 129: ...127 ...
Page 130: ...128 ...
Page 131: ...129 ...