13
English
CAUTION:
Risk of property damage. The wheels and handle do
not provide adequate clearance, stability or support for pulling the
unit up and down stairs or steps. The unit must be lifted, or pushed
up a ramp.
CAUTION:
Risk of property damage. Place engine fuel valve lever
(T) in the OFF position before moving or transporting unit.
When transporting the
W
V,W
P
V,W
V
compressor in a vehicle,
trailer, etc. ensure that the
air tank is drained and the
unit is secured and placed
on a protective mat on a flat
horizontal surface.
DO NOT
transport in a standing
position.
NOTE:
Use
recommended tie down points (V) when transporting. Use care
when driving so to avoid tipping the unit over in the vehicle. Damage
can occur to the unit or surrounding items if unit is tipped. Use a
ramp if loading or unloading the unit from a height of more than 12"
(30.5 cm).
LIFTING
WARNING:
Risk injury from lifting. Unit weighs more than 160 lbs.
(72.6 kg) Do not move or lift without assistance.
CAUTION:
Risk of property damage. Place engine fuel valve lever
(T) in the OFF position before moving or transporting unit.
Always use two people when lifting and lift from the recommended
lift points (W).
MOVING
1. Grasp handle (P) of compressor, and lift compressor high
enough so unit can be rolled on the front tires.
WARNING:
Risk of unsafe operation. Ensure proper footing and
use caution when rolling compressor so that unit does not tip or
cause loss of balance.
CAUTION:
Risk of property damage. Place engine fuel valve lever
(T) in the OFF position before moving or transporting unit.
2. When location is reached slowly lower rear of compressor
to ground. Always store compressor in a horizontal position.
NOTE: DO NOT
store in a standing position.
NOTE:
Should the unit tip over, hard starting and smoking will occur
due to oil spillage.
General Requirements
The piping, fittings, receiver tank, etc. must be certified safe for at
least the maximum working pressure of the unit. Use hard welded
or threaded steel or copper pipes, cast iron fittings and hoses that
are certified safe for the units discharge pressure and temperature.
Use pipe thread sealant on all threads, and tighten joints thoroughly
to prevent air leaks.
DO NOT USE PVC PLASTIC.
WARNING:
Risk of bursting. Plastic or PVC pipe is not designed
for use with compressed air. Regardless of its indicated pressure
rating, plastic pipe can burst from air pressure. Use only metal pipe
for air distribution.
CONDENSATE DISCHARGE PIPING
If installing a condensate discharge line, the piping must be at least
one size larger than the connection, as short and direct as possible,
secured tightly and routed to a suitable drain point. Condensate
must be disposed of in accordance with local, state and federal laws
and regulations.