17
Tool operates, but does not drive the fastener fully
Low battery charge or damaged battery
Charge or replace battery
Depth adjustment set too shallow
Rotate depth adjustment wheel to a deeper
setting
Tool not firmly applied to workpiece
See instruction manual
Material and fastener length
Choose appropriate material or fastener length
too rigorous an application
Damaged or worn driver blade tip
Replace driver/return assembly; see authorized
service
center
Damaged or worn driver/return assembly
Replace driver/return assembly; see authorized
service
center
Tool operates, but no fastener driven
No fasteners in magazine
Load fasteners into magazine
Wrong size or angle fasteners
Use only recommended fasteners
Debris in nosepiece
Clean nosepiece
Debris in magazine
Clean magazine
Worn magazine
Replace magazine; see authorized service
center
Damaged or worn driver blade
Replace driver/return assembly; see authorized
service
center
Damaged pusher spring
Replace spring; see authorized service center
Jammed fastener
Wrong size or angle fasteners
Use only recommended fasteners
Damaged or worn driver blade
Replace driver/return assembly; see authorized
service
center
Material and fastener length
Material or fastener length inappropriate
too rigorous an application
Low battery charge or damaged battery
Charge or replace battery
Debris in nosepiece
Clean nosepiece
Debris in magazine
Clean magazine
Worn magazine
Replace magazine; see authorized service center
Worn or damaged pusher spring
Replace spring; see authorized service center
Troubleshooting Guide (cont'd)