English
10
5. Set the Auto On/Off switch to "Auto On" position.
Quick-Connect Coupler
9
:
The quick connect body
accepts industrial quick connect plugs.
How to Use Your Unit (Fig. E)
How to Stop
1. Set the Auto On/Off switch
1
to "Off".
2. Remove battery when not in use.
Before Starting
WARNING:
Do not operate this unit until you read
this instruction manual for safety, operation and
maintenance instructions.
Before Each Start-Up
1. Remove battery. (Refer to
installing and Removing
the Battery Pack
)
2. Set the Auto On/Off switch
1
to "Off".
3. Turn the regulator
6
counterclockwise to set the outlet
pressure to zero.
4. Attach hose and accessories.
WARNING: Risk of unsafe operation. Firmly grasp
air hose in hand when installing or disconnecting
to prevent hose whip.
WARNING: Risk of unsafe operation. Do not use
damaged or worn accessories.
nOTE:
The hose or accessory will require a quick connect
plug if the air outlet is equipped with a quick connect
body
9
.
WARNING: Risk of Bursting.
Too much air pressure
causes a hazardous risk of bursting. Check the
manufacturer’s maximum pressure rating for air tools
and accessories. The regulator outlet pressure must
never exceed the maximum pressure rating.
NOTICE:
Risk of property damage. Compressed air
from the unit may contain wa ter condensation and
oil mist. Do not spray un fil tered air at an item that
could be damaged by moisture. Some air tools and
accessories may require filtered air. Read the in struc-
tions for the air tools and accessories.
How to Start
1. Install the battery into the tool.
2. Set the Auto On/Off switch
1
to "Auto On" and allow
tank pressure to build. Motor will stop when tank
pressure reaches "cut-out" pressure.
3. Turn regulator
6
clockwise to increase pressure and
stop when desired pressure is reached.
WARNING: Risk of unsafe operation. If any
unusual noise or vibration is noticed, stop the
compressor immediately and have it checked by
a trained service technician
.
WARNING:
Ensure the regulator is set to a pressure
lower than the maximum operating pressure of
the tool.
The compressor is ready for use.
Fig. E
1
6
4
9
MAINTENANCE
WARNING: To reduce the risk of serious personal
injury, turn unit off and remove the battery pack
before making any adjustments or removing/
installing attachments or accessories.
An
accidental start-up can cause injury.
Customer Responsibilities
Before each
use
Daily or after
each use
See tank
warning label
Check Safety Valve
X
Drain Tank
X
Remove tank from service
X
***
*** For more information, call 1–800–4-
D
e
W
ALT (1–800–433–9258)
WARNING:
Risk of unsafe operation. Unit cycles
automatically when power is on.
When performing maintenance, you may be exposed
to voltage sources, compressed air, or moving parts.
Personal injuries can occur. Before performing any
maintenance or repair, disconnect power source from
the compressor and bleed off all air pressure.
nOTE:
See
Operation
section for the location of controls.
To Check Safety Valve (Fig. E)
WARNING:
Risk of Bursting. If the safety valve does
not work properly, over-pressurization may occur,
causing air tank rupture or an explosion.
WARNING: Risk from Flying Objects.
Always wear
certified safety equipment: ANSI Z87.1 eye protection
(CAN/CSA Z94.3) with side shields.
Before starting compressor, pull the ring on the safety
valve
4
to make sure that the safety valve operates freely. If
the valve is stuck or does not operate smoothly, it must be
replaced with the same type of valve.