26
EngLIsh
An estimation of the level of exposure to vibration and/
or noise should also take into account the times when the
tool is switched off or when it is running but not actually
doing the job. This may significantly reduce the exposure
level over the total working period.
Identify additional safety measures to protect the
operator from the effects of vibration and/or noise such
as: maintain the tool and the accessories, keep the
hands warm (relevant for vibration), organisation of
work patterns.
The vibration and/or noise emission level given in this
information sheet has been measured in accordance with
a standardised test given in EN62841 and may be used to
compare one tool with another. It may be used for a preliminary
assessment of exposure.
WARNING:
The declared vibration and/or noise emission
level represents the main applications of the tool. However
if the tool is used for different applications, with different
accessories or poorly maintained, the vibration and/or
noise emission may differ. This may significantly increase
the exposure level over the total working period.
English (original instructions)
ALLIGATOR SAW
DCS396, DCS397, DCS398
Congratulations!
You have chosen a
D
e
WALT
tool. Years of experience, thorough product development and innovation make
D
e
WALT
one of the most
reliable partners for professional power tool users.
Technical Data
DCS396
DCS397
DCS398
Voltage
V
DC
54
54
54
Type
1
1
1
Battery type
Li-Ion
Li-Ion
Li-Ion
Power output
W
900
1000
1000
No load speed
min
-1
2400
2400
2400
Stroke length
mm
40
40
40
Cutting length
mm
295
430
430
Weight (without battery pack)
kg
5.5
5.6
5.6
Noise values and/or vibration values (triax vector sum) according to EN62841-2-11:
L
PA
(emission sound pressure level)
dB(A)
92
92
92
L
WA
(sound power level)
dB(A)
103
103
103
K (uncertainty for the given sound level)
dB(A)
5
5
5
Cutting clay building blocks
Vibration emission value a
h,PCB
=
m/s
2
4.1
4.1
4.1
Uncertainty K =
m/s
2
1.5
1.5
1.5
Cutting wood/chipboard & plastic
Vibration emission value a
h,WP
=
m/s
2
4.1
4.1
4.1
Uncertainty K =
m/s
2
1.5
1.5
1.5
Cutting cellular concrete
Vibration emission value a
h,CC
=
m/s
2
4.1
4.1
4.1
Uncertainty K =
m/s
2
1.5
1.5
1.5
Cutting insulation material
Vibration emission value a
h,IM
=
m/s
2
4.1
4.1
4.1
Uncertainty K =
m/s
2
1.5
1.5
1.5
Summary of Contents for DCS396
Page 1: ...DCS396 DCS397 DCS398 Final Page size A5 148mm x 210mm ...
Page 3: ...1 Fig A Fig B 9 1 2 4 8 7 17 5 6 3 10 9 10 18 ...
Page 4: ...2 Fig C Fig D 12 7 11 12 13 11 ...
Page 5: ...3 Fig F Fig E 20 6 14 15 16 14 19 ...
Page 6: ...4 Fig G ...
Page 145: ...143 ...
Page 146: ...144 ...
Page 147: ...145 ...