48
WARNING:
When replacing batteries, always replace the
complete set. Do not mix old batteries with new ones.
Preferably use alkaline batteries.
Low battery indicator (fi g. A)
The tool has been equipped with a low battery indicator (3) located on the
control panel. The low battery indicator is lit while the tool is switched on.
It will blink to indicate that the batteries need to be replaced and the tool
will automatically shut down.
• Switch off the tool and remove the batteries as soon as the indicator
blinks.
Setting up the tool (fi g. C1 - C4)
The tool facilitates various set-ups, making it useful for several applications.
Floor set-up
• Place the tool on a relatively smooth and level surface.
Wall set-up (fi g. C1)
The keyhole (12) in the pivot bracket (8) is used for mounting to wall
constructions. Alternatively, the tool can be attached to metal studs
directly using the magnets (13).
• Drive a screw or nail into the wall.
• Hang the tool onto the fastener by the keyhole.
Fitting the tool to the wall mount (fi g. C2 - C4)
The tool has been equipped with a wall mount (9) for mounting to wall
track to aid in drop ceiling installation and other specialty leveling projects.
The pivot bracket (8) has magnets to attach the tool to the wall mount.
• Align the magnets (13) with the metal plate on the wall mount (9).
• To remove the wall mount, pull the wall mount from the tool applying
suffi cient force.