background image

6

Keypad, Modes and LED.

Power switch.

The Power ON/OFF switch is located on the front of the tool as shown in figure 1 (A). When the switch (A) is in the OFF/LOCKED position, the 

unit will remain off and the pendulum will be locked

When the on/off switch (A) is in the ON/UNLOCKED position, the unit will be powered ON, the pendulum will be released from the locked position and self level.

Out of Level Indicator

The DW08801 is equipped with an out of level indicator. When the tilt range (> 4° tilt) has been exceeded the laser beam will flash. 
The flashing beam indicates that the tool IS NOT LEVEL (OR PLUMB) AND SHOULD NOT BE USED FOR DETERMINING OR MARKING LEVEL (OR PLUMB). Try repositioning 

the laser on a more level surface.

Batteries & Power

Your laser tool requires 2 x AA batteries. (B)
Use only new, high-quality batteries for best results.

• 

 Ensure batteries are in good working condition. If the low battery indicator light is flashing, the batteries need replacement.

• 

To extend battery life, turn laser off when not working with or marking the beam.

Set Up

LEVELING THE LASER

This tool is self-leveling. It is calibrated at the factory to find plumb as long as it is positioned on flat surface within 4° of level. As long as the tool is properly calibrated, 

no manual adjustments must be made.

To ensure the accuracy of your work, check to make sure your laser is calibrated often. See 

Field Calibration Check.

•  Before attempting to use the laser, make sure it is positioned securely, on a smooth, flat surface.
•  Always mark the center of the dot or pattern created by the laser.
•  Extreme temperature changes may cause movement of internal parts that can affect accuracy. Check your accuracy often while working. See 

Field Calibration 

Check.

•  If the laser has been dropped, check to make sure your laser is calibrated. See 

Field Calibration Check.

OPERATION
TURNING THE LASER ON AND OFF (FIG. 3)

• 

With the laser off, place it on a stable, flat surface. Turn the laser on by sliding on/off switch (A) to the ON/UNLOCKED position. 

• 

To turn the laser off, slide the the on/off switch (A) to the locked position. 

The DW08801 is equipped with a locking pendulum mechanism. This feature is only activated when the laser is switched off. 

USING THE LASER

The beams are level or plumb as long as the calibration has been checked (see 

Field Calibration Check

) and the laser beam is not flashing (see 

Out of level Range 

Indicator

).

The tool can be used to transfer points using any combination of the five beams and/or horizontal line.

OPERATING TIPS

To ensure the accuracy of your work, check to make sure your laser is calibrated often. See 

Field Calibration Check.

•  Before attempting to use the laser, make sure it is positioned securely, on a smooth, flat surface.
•  Always mark the center of the dot or pattern created by the laser.
•  Extreme temperature changes may cause movement of internal parts that can affect accuracy. Check your accuracy often while working. See 

Field Calibration 

Check.

•  If the laser has been dropped, check to make sure your laser is calibrated. See 

Field Calibration Check.

USING THE LASER WITH ACCESSORIES

The laser is equipped with 1/4” x 20  female threads on the bottom of the unit. These threads may be used to accommodate current or future D

e

WALT accessories. 

Only use D

e

WALT accessories specified for use with this product. Follow the directions included with the accessory. 

 WARNING: 

Since accessories, other than those offered by D

e

W

ALT, have not been tested with this product, use of such accessories with this tool could be hazardous. 

To reduce the risk of injury, only D

e

W

ALT

 recommended accessories should be used with this product. 

Recommended accessories for use with your tool are available at extra cost from your local dealer or authorized service center. If you need assistance in locating any 

accessory, please contact D

e

WALT Industrial Tool Co., 701 East Joppa Road, Towson, MD 21286, call 1-800-4-D

e

WALT (1-800-433-9258) or visit our website: www.

D

E

WALT.com.

Summary of Contents for DW08801

Page 1: ...ES INSTRUCTIVO DE OPERACIÓN CENTROS DE SERVICIO Y PÓLIZA DE GARANTÍA ADVERTENCIA LÉASE ESTE INSTRUCTIVO ANTES DE USAR EL PRODUCTO Questions See us 0n the World Wide Web at www dewalt com Perguntas Visite nos na World Wide Web em www dewalt com DW08801 Self Leveling Cross Line Laser ...

Page 2: ...2 ENGLISH original instructions 4 FRANÇAIS traduction de la notice d instructions originale 10 ESPAÑOL traducido de las instrucciones originales 16 PORTUGUÊS traduzido das instruções originais 23 ...

Page 3: ... 3 FIG 1 FIG 2 FLASHING CLIGNOTANT DESTELLA FIG 4 FIG 5 1 Power Switch 2 Laser Aperture 3 Battery Compartment 4 Label Information FIG 3 4 AVERAGE EN MOYENNE PROMEDIO MÉDIA ...

Page 4: ...tapes 4 5 Pasos 4 5 Passos 4 5 Step 6 Étape 6 Paso 6 Passo 6 Step 7 Étape 7 Paso 7 Passo 7 Step 3 Étape 3 Paso 3 Passo 3 FIG 7 FIG 6 b Step 1 Étape 1 Paso 1 a Step 2 Étape 2 Paso 2 45 Step 3 Étape 3 Paso 3 Step 4 Étape 4 Paso 4 Step 2 Étape 2 Paso 2 Step 3 Étape 3 Paso 3 90 P1 L D1 2 x L P2 P3 P1 L D1 2 x L P2 P3 P4 J D2 P1 P4 J3 J1 J2 ...

Page 5: ...laser notice No 50 dated June 24 2007 PRODUCT OVERVIEW The DW08801 laser level is a self leveling laser tool that can be used for horizontal level and vertical plumb alignment and square alignment This tool comes fully assembled and has been designed with features that allow for quick and easy set up Please read and understand all instructions within this instruction manual in addition the Safety ...

Page 6: ... 3 With the laser off place it on a stable flat surface Turn the laser on by sliding on off switch A to the ON UNLOCKED position To turn the laser off slide the the on off switch A to the locked position The DW08801 is equipped with a locking pendulum mechanism This feature is only activated when the laser is switched off USING THE LASER The beams are level or plumb as long as the calibration has ...

Page 7: ...stance Between Marks 15 1 32 30 1 16 50 1 4 CHECKING ACCURACY HORIZONTAL BEAM PITCH DIRECTION FIG 7 When checking the horizontal beam it is important to conduct a calibration check using a distance no shorter than the distance of the applications for which the tool will be used 1 Mount the laser on a tripod as close as possible to a wall at distance D1 Wall 1 2 Turn on the laser and project the ho...

Page 8: ...DeWALT Industrial Tool Co 701 East Joppa Road Towson MD 21286 Apr 14 Form No N296281 Copyright 2014 DeWALT ...

Reviews: