background image

  7

Field Calibration Check

CHECKING ACCURACY – HORIZONTAL BEAM, SCAN DIRECTION (FIG. 6)

Checking the horizontal scan calibration of the laser requires two walls 30’ (9m) apart. It is important to conduct a calibration check using a distance no shorter than 

the distance of the applications for which the tool will be used.
  1. Attach the laser to a wall using a pivot bracket. Make sure the laser is facing straight ahead. 
  2. Turn on the laser’s beams and pivot the laser approximately 45˚ so that the right-most end of the laser line is striking the opposing wall at a distance of at 

least 30’ (9m). Mark the center of the beam (a).

  3. Pivot the laser approximately 90˚ to bring the left-most end of the laser line around to the mark made in Step 2. Mark the center of the beam (b).
  4. Measure the vertical distance between the marks.
  5. If the measurement is greater than the values shown below, the laser must be serviced at an authorized service center.

Distance Between Walls

Allowable Distance Between Marks 

15' 

1/32”

30' 

1/16” 

50' 

1/4" 

CHECKING ACCURACY – HORIZONTAL BEAM, PITCH DIRECTION (FIG. 7)

When checking the horizontal beam it is important  to conduct  a calibration check  using  a distance no shorter  than the 

 

distance of the applications for which the tool will be used.

1.     Mount the laser on a tripod as close as possible to a wall at distance D1. (Wall #1)
2.     Turn on the laser and project the horizontal beam onto the nearest wall. (Wall #1)
3.     Mark the center of the beam at Point P1.
4.     Rotate the laser 180

°

 and mark the center of the beam on the opposing wall  (Wall #2) at Point P2.

5.     Reposition the laser close to the opposite wall  (Wall #2) at distance D1.
6.     Turn on the laser and project the horizontal beam onto Wall #2
7.    Adjust the height of the laser so that the center of the beam is aligned with Point P2.
8.     Rotate the laser 180

°

 and mark the center of the beam on the opposing wall  (Wall #1) at Point P3.

9.     Measure the distance between thesepoints  P1 and P3.
10.  If the measurement is greater than the values shown below, the laser must be serviced at an authorized service center.

 

 

 

     

Distance Between Walls

Measurement Between Marks 

15' (4.5 m)

1/32”

30' (9 m)

1/16” 

50' (15 m)

1/4" 

Summary of Contents for DW08801

Page 1: ...ES INSTRUCTIVO DE OPERACIÓN CENTROS DE SERVICIO Y PÓLIZA DE GARANTÍA ADVERTENCIA LÉASE ESTE INSTRUCTIVO ANTES DE USAR EL PRODUCTO Questions See us 0n the World Wide Web at www dewalt com Perguntas Visite nos na World Wide Web em www dewalt com DW08801 Self Leveling Cross Line Laser ...

Page 2: ...2 ENGLISH original instructions 4 FRANÇAIS traduction de la notice d instructions originale 10 ESPAÑOL traducido de las instrucciones originales 16 PORTUGUÊS traduzido das instruções originais 23 ...

Page 3: ... 3 FIG 1 FIG 2 FLASHING CLIGNOTANT DESTELLA FIG 4 FIG 5 1 Power Switch 2 Laser Aperture 3 Battery Compartment 4 Label Information FIG 3 4 AVERAGE EN MOYENNE PROMEDIO MÉDIA ...

Page 4: ...tapes 4 5 Pasos 4 5 Passos 4 5 Step 6 Étape 6 Paso 6 Passo 6 Step 7 Étape 7 Paso 7 Passo 7 Step 3 Étape 3 Paso 3 Passo 3 FIG 7 FIG 6 b Step 1 Étape 1 Paso 1 a Step 2 Étape 2 Paso 2 45 Step 3 Étape 3 Paso 3 Step 4 Étape 4 Paso 4 Step 2 Étape 2 Paso 2 Step 3 Étape 3 Paso 3 90 P1 L D1 2 x L P2 P3 P1 L D1 2 x L P2 P3 P4 J D2 P1 P4 J3 J1 J2 ...

Page 5: ...laser notice No 50 dated June 24 2007 PRODUCT OVERVIEW The DW08801 laser level is a self leveling laser tool that can be used for horizontal level and vertical plumb alignment and square alignment This tool comes fully assembled and has been designed with features that allow for quick and easy set up Please read and understand all instructions within this instruction manual in addition the Safety ...

Page 6: ... 3 With the laser off place it on a stable flat surface Turn the laser on by sliding on off switch A to the ON UNLOCKED position To turn the laser off slide the the on off switch A to the locked position The DW08801 is equipped with a locking pendulum mechanism This feature is only activated when the laser is switched off USING THE LASER The beams are level or plumb as long as the calibration has ...

Page 7: ...stance Between Marks 15 1 32 30 1 16 50 1 4 CHECKING ACCURACY HORIZONTAL BEAM PITCH DIRECTION FIG 7 When checking the horizontal beam it is important to conduct a calibration check using a distance no shorter than the distance of the applications for which the tool will be used 1 Mount the laser on a tripod as close as possible to a wall at distance D1 Wall 1 2 Turn on the laser and project the ho...

Page 8: ...DeWALT Industrial Tool Co 701 East Joppa Road Towson MD 21286 Apr 14 Form No N296281 Copyright 2014 DeWALT ...

Reviews: