13
English
Chisel Assembly Continued
• Using the
front tab (H), tightly install the spring retainer (G)
over the
chisel (J).
• Slide the
chisel shank (K) into the barrel (A) of the Air
Chisel Hammer.
• Screw the
spring retainer (G) onto the threads on the end
of the
barrel (A) until fully installed.
IMporTAnT: The spring retainer holds chisel in place. It must
be secure before the chisel can operate properly.
OPERATING PROCEDURES
START-UP (FIG. 1, PG. 2)
• Connect tool to air hose of recommended size.
• Turn on the air compressor and allow the air tank to be filled.
• Set the air compressor regulator to 90 PSI. This air
tool operates at a maximum of 90 PSI air pressure.
• Depress the trigger to start operating the tool.
SHUT-DOWN (FIG. 1, PG. 2)
• Release the trigger in order to stop the tool.
• When job is completed, turn off the air compressor and store
the air tool after lubrication.
• When changing chisels, always disconnect air supply to
avoid injuries.
OPERATING INSTRUCTIONS
• Select chisel/attachment to perform the work task and
ensure that the chisel retainer is securely fitted. Do not use
tool without retainer spring retainer securely fitted.
• While firmly gripping the tool with the right hand, grasp the
barrel with the left hand. The tool’s power is controlled by
the pressure exerted on the trigger.
• Always ensure that the tool is in contact with the work
piece before pressing the trigger. Running the tool free
will reduce tool life by placing unnecessarily high loads on
he retainer spring and cylinder.
J
K
A
J
G
G
H
A