For example, if your fastener usage averages 30 fasteners per minute,
you need 50% of the tool’s cfm. required to operate the tool at the
rate of 60 fasteners per minute. In this case, be sure that your air
compressor can deliver a minimum of 1.42 cfm (40.2 lt/min) at 80 psi
(5.6 kg/cm
2
) for optimum performance.
COMPONENTS (FIG. 1)
A. Trigger
B. Trigger mode selector
C. Jam clearing latch
D. Contact trip
E. Contact disc
F. Magazine
G. Pusher
H. Air inlet
I.
Rear
exhaust
J. Adjustable belt hook
K. Depth adjustment wheel
L. Low nail indicator
H
A
D
I
F
B
C
G
J
E
K
L
FIG. 1
OPERATION
Preparing the Tool
WARNING:
Read the section titled
Important Safety Instructions
at the beginning of this manual. Always wear eye and ear protection
when operating this tool. Keep the stapler pointed away from yourself
and others. For safe operation, complete the following procedures
and checks before each use of the stapler.
CAUTION: NEVER
spray or in any other way apply lubricants or
cleaning solvents inside the tool. This can seriously affect the life and
performance of the tool.
NOTE:
These staplers are designed to be used without oil.
1. Before you use the stapler, be sure that the compressor tanks
have been properly drained.
2. Wear proper eye, hearing and respiratory protection.
3. Remove all fasteners from the magazine.
4. Check for smooth and proper operation of contact trip and
pusher assemblies. Do not use tool if either assembly is not
functioning properly. NEVER use a tool that has the contact trip
restrained in the up position.
5. Check air supply. Ensure that air pressure does not exceed
recommended operating limits, refer to
Tool Specifications
.
6. Connect air hose.
7. Check for audible leaks around valves and gaskets. Never use
a tool that leaks or has damaged parts.
WARNING:
To reduce the risk of personal injury, disconnect tool
from air supply before performing maintenance, clearing a jammed
fastener, leaving work area, moving tool to another location or
handing the tool to another person.