22
English
CoDe
PossIBle CAuse
PossIBle solutIon
5
Leaking seals
Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center.
6
Defective safety valve
Operate safety valve manually by pulling on ring. If valve still leaks,
it must be replaced.
7
Prolonged excessive use of air
Decrease amount of air usage.
8
Compressor is not large enough for accessory
Check the accessory air requirement. If it is higher than the SCFM
or pressure supplied by your air compressor, a larger compressor
is needed to operate accessory.
9
Hole in air hose
Check and replace air hose, if required.
10
Unloader valve restricted
Remove, clean or replace.
11
Unit operating in damp or humid conditions
Move unit to a dry well ventilated area.
12
Restricted air intake filter
Clean or replace air intake filter.
13
Loose belt
Check belt tension, see Adjusting Belt tension under
Maintenance.
14
Engine mount ing bolts are loose
Tighten mounting screws. Torque engine mounting bolts to
10– 20 ft.-lbs. (13.5–27.1 Nm).
WARNING: Risk of bursting. Excessive vibration could weaken
the air tank and cause it to rupture or explode. Mounting screws
must be kept tightened.
15
Pump stiffener bracket bolt is loose
Check bolt and tighten if required. Torque pump stiffener bracket
bolt to 10– 20 ft.-lbs. (13.5–27.1 Nm).
WARNING: Risk of bursting. Excessive vibration could weaken
the air tank and cause it to rupture or explode. Stiffener bracket
bolt must be kept tightened. Never operate the unit unless
equipped with the stiffener bracket.
Summary of Contents for DXCMH1608WB