22
English
CODE
POSSIBLE CAUSE
POSSIBLE SOLUTION
13
Engine mount ing bolts are loose
Tighten mounting screws. Torque engine mounting bolts to
10– 20 ft.-lbs. (13.5–27.1 Nm).
WARNING:
Risk of bursting. Excessive vibration could weaken
the air tank and cause it to rupture or explode. Mounting screws
must be kept tightened.
14
Air tank pressure is too high
Open the regulator and reduce air tank pressure to less than
40 psi.
15
Engine problem
Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center.
16
Engine oil is low
See engine instruction manual.
17
It is normal for
some
pressure drop to occur
If there is an excessive amount of pressure drop when the
accessory is used, adjust the regulator as instructed in
Regulator
under
Features
.
NOTE:
Adjust the regulated pressure under flow conditions while
accessory is being used.
18
Damaged regulator
Replace.
19
Manual lock unloader lever in
open
position
Rotate manual lock unloader lever to the
closed
perpendicular
position.
20
Regulator open
Rotate the regulator knob counterclockwise to its built-in stop.
21
Engine fuel tank empty
Add gasoline, see engine's instruction manual for correct procedure.