background image

USER MANUAL 

E-Mobility DEMO 

 

 

 

System and Components Recycling 

Production of these components required the extraction and use of natural resources. The substances 
contained in the system could be harmful to your health and to the environment if the system is 
improperly handled at its end of life! Please recycle this product in an appropriate way to avoid 
unnecessary pollution of the environment and to keep natural resources. 
 

This symbol indicates that this system complies with the European Union’s requirements 
according to Directive 2002/96/EC on waste electrical and electronic equipment (WEEE). 
Please find further information about recycling on the Dewesoft web site 

www.dewesoft.com

 

 
Restriction of Hazardous Substances 

This product has been classified as Monitoring and Control equipment and is outside the scope of the 
2002/95/EC RoHS Directive. However, we take care of our environment and the product is lead-free. 

 

General safety and hazard warnings for all Dewesoft systems 

Safety of the operator and the unit depend on following these rules. 

Use this system under the terms of the specifications only to avoid any possible danger. 

Read your manual before operating the system. 

Observe local laws when using the instrument. 

DO NOT touch internal wiring! 

DO NOT use higher supply voltage than specified! 

Use only original plugs and cables for harnessing. 

You may not connect higher voltages than rated to any connectors. 

The power cable and connector serve as Power-Breaker. The cable must not exceed 3 meters, 
the disconnect function must be possible without tools. 

Maintenance must be executed by qualified staff only. 

During the use of the system, it might be possible to access other parts of a more 
comprehensive system. Please read and follow the safety instructions provided in the manuals of 
all other components regarding warning and security advice for using the system. 

With this product, only use the power cable delivered or defined for the host country. 

DO NOT connect or disconnect sensors, probes or test leads, as these parts are connected to a 
voltage supply unit. 

Ground the equipment: For Safety Class 1 equipment (equipment having a protective earth 
terminal), a non-interruptible safety earth ground must be provided from the mains power 
source to the product input wiring terminals. 

Please note the characteristics and indicators of the system to avoid fire or electric shocks. 
Before connecting the system, please read the corresponding specifications in the product 
manual carefully. 

The inputs must not unless otherwise noted (CATx identification), be connected to the main 
circuit of category II, III and IV. 

 

 

1.1  Version of the document 

24 

Summary of Contents for E-Mobility DEMO

Page 1: ...E Mobility DEMO USER MANUAL 1 1 Version of the document...

Page 2: ...ended software 7 Connecting to the device 8 Connecting the car 8 Voltage measurement 8 Battery voltage measurement 8 Motor voltage measurement 9 Current measurement 9 Road speed 10 Setting up the soft...

Page 3: ...n 19 Warranty information 21 Calibration 21 Support 21 Service repair 21 Restricted Rights 21 Printing History 22 Copyright 22 Trademarks 22 Safety instructions 23 Safety symbols in the manual 23 Gene...

Page 4: ...speed of the car can be calculated The car is attached to the road with standard SIRIUS plastic feet that can be detached so the car can be removed Once removed it can be driven as a normal RC Car Wa...

Page 5: ...ntrol Desert FOX 1 10 4WD Electric car with Current CT s and Voltage measurement connections DSUB25 to SIRIUS connection cable Rolling road base with Tacho Li Po Battery 2S 7 4V 5000mAh 20C Max 45Wh w...

Page 6: ...to store all required SIRIUS accessories if you choose to transport your measurement equipment in the same case C By lifting the foam insert in upwards direction beneath it you will find the E Mobilit...

Page 7: ...commend the following Hardware as it s the most likely to be used in a real application SIRIUSi HS of XHS 4x HV 2x LV 2x LV 8x AO For control Recommended software We recommend using the latest version...

Page 8: ...nt system you first need to connect the Female DSUB 25 connector to the Male DSUB 25 located on the car b Voltage measurement Battery voltage measurement To measure the voltage of the battery you need...

Page 9: ...lete the Delta connection with the corresponding cables c Current measurement To connect the Current transducers from the car to the measurement unit you need to connect the DSUB9 connectors to the LV...

Page 10: ...upply power to the Tacho with 10 30VDC If your speed drops when the car is accelerating it could be that the distance between the Proximity probe and the screw located in the roller is too big To fix...

Page 11: ...Web page under Support Downloads a Analog inputs Voltage channel setup The car is powered by a 2 cell LiPo battery that has a nominal voltage of 7 4V and a Maximum of 8 4V when charged For this reason...

Page 12: ...is sufficient for this measurement If TEDS is neither programmed nor recognised refer to the datasheet table for information Configuration Amplifier Value Measurement Voltage Range 10 Low pass filter...

Page 13: ...0125 V A Offset 0 A b Counters For setting up the speed go to Ch setup and add Counters module Math setup To calculate the speed of the car we can make a formula Where RPMChannel Counter input channel...

Page 14: ...Please charge the battery to full potential before use Warning When you finish using the demo ALWAYS DISCONNECT the BATTERY Charging the battery To charge the battery first plug the charger into the m...

Page 15: ...USER MANUAL E Mobility DEMO b Battery charger operation 1 1 Version of the document 15...

Page 16: ...USER MANUAL E Mobility DEMO c Remote control operation 1 1 Version of the document 16...

Page 17: ...he ESC will cut power when the voltage limit is reached The car s ESC should be preset to the right configuration for the intended application of use In case the ESC was not set correctly please set t...

Page 18: ...arning Always turn on the remote control prior to connecting the battery and switching ON the RC Car Turning on the remote control To turn on the remote control open the plastic cover by holding it at...

Page 19: ...position as indicated in the picture DEWESoft X analogue control configuration Caution Always set the sampling rate to Maximum frequency The output sampling rate is dependant on the sampling rate set...

Page 20: ...USER MANUAL E Mobility DEMO B Add math modules to simulate PWM C Configure Analog OUT D Add Automatic Run up User inputs and Math 1 1 Version of the document 20...

Page 21: ...s to be calibrated at regular intervals The standard norm across nearly every industry is annual calibration Before your Dewesoft data acquisition system is delivered it is calibrated Detailed calibra...

Page 22: ...demarks We take pride in our products and we make sure that all key products and technologies are registered as trademarks all over the world The Dewesoft name is a registered trademark Product famili...

Page 23: ...d during all phases of operation service and repair of this product Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design manu...

Page 24: ...ment DO NOT touch internal wiring DO NOT use higher supply voltage than specified Use only original plugs and cables for harnessing You may not connect higher voltages than rated to any connectors The...

Page 25: ...iously or causes strange noises the system does not work anymore the system has been exposed to long storage in adverse environmental the system has been exposed to heavy shipment strain Warranty void...

Page 26: ...Please also consider the detailed technical reference manual as well as the security advice of the connected systems This product has left the factory in safety related flawless and in proper conditio...

Page 27: ...__________________________ __________________________________________________________________________ __________________________________________________________________________ _______________________...

Page 28: ...USER MANUAL E Mobility DEMO 1 1 Version of the document 28...

Reviews: