4.1.5. Open interface protocols
In today’s world of open toolchain and intercommunication, each device should be compliant with
standard protocols. All protocols can be used at the same time.
OPC UA: is the industry standard. Actually, it is more than a standard, it is a perfect framework where
the device can be described and set up in any system, including SCADA, MES, ERP, mobile devices and
others.
XCP: Starting with version 1.4., XCP became a very powerful interface protocol in the automotive
industry for data exchange. In the modern age of e-mobility, the required sampling rates are much
higher than ever and 1 GBIT XCP interface allows data transfers with as high as 5 Ms/sec.
CAN/CAN FD: Vehicle bus systems can be read through the CAN FD interface while the measured data
can be also transmitted through this “golden” standard protocol.
4.1.6. Power analyzer
Dewesoft software will automatically calculate and store not only raw data from the voltage and current
transducers but also all the power parameters: P, Q, S, D, Cos
φ
, power factor, P, Q, cos
φ
for each
harmonic and other relevant power parameters.
Each parameter can visually be displayed in a time recorder, digital or analog display.
Using a computer graphics card as a multi-threaded calculation platform, the Dewesoft power module
can calculate all those parameters up to a full speed of 15 Ms/sec.
4.1.7. Data Acquisition Software Included for Free
All Dewesoft data acquisition systems are bundled with award winning Dewesoft X Professional DAQ
software. Dewesoft X is the world's most advanced and easy-to-use data acquisition and analysis
software. Dewesoft X's flexibility and power will help you unleash the DAQ system to its full potential and
gives you many advantages over other DAQ systems. Functionalities like plug-and-play, hardware
auto-detection, smart TEDS sensors, advanced storing and data analysis features will take your
measurement and analysis needs to a whole new level.