Page 1: ...SIRIUSi XHS PWR TECHNICAL REFERENCE MANUAL SIRIUSi XHS PWR V21 1 ...

Page 2: ...annel setup 18 3 3 3 Sample rate 18 3 3 4 Measurement Mode 19 3 3 5 Analyse Mode 19 3 4 Advanced configuration 20 3 5 Firmware upgrade 21 3 6 Licensing 22 3 7 Troubleshooting 23 4 System overview 24 4 1 Main features 25 4 1 1 Hybrid ADC technology 26 4 1 2 Perfect synchronization 26 4 1 3 Perfect amplifiers for power measurements 27 4 1 4 E mobility power device 27 4 1 5 Open interface protocols 2...

Page 3: ...RENCE MANUAL 7 Notice 33 7 1 Warranty Information 33 7 2 Calibration 33 7 3 Support 33 7 4 Service repair 33 7 5 Restricted Rights 33 7 6 Copyright 34 7 7 Trademarks 34 7 8 Documentation version history 35 SIRIUSi XHS PWR V21 1 3 39 ...

Page 4: ... description of the mechanical connections and variants of current ranges A comprehensive introduction to the configuration of the modules using DewesoftX Detailed technical data Specifications etc 1 1 Legend The following symbols and formats will be used throughout the document Important Gives you important information about a subject Please read carefully Hint Gives you a hint or provides additi...

Page 5: ...S PWR technical reference manual 1 2 2 DewesoftX tutorials The DewesoftX tutorials document provides basics and additional information and examples for working with DewesoftX and certain parts of the program The latest version of the DewesoftX tutorials can be found here https download dewesoft com list manuals brochures software manuals In the Software Manuals section click the download link of t...

Page 6: ...ty instructions Your safety is our primary concern Please be safe Warning Prior to first usage it is recommended to read Safety Reference Manual in a separate document SIRIUSi XHS PWR Safety Technical Reference Manual V21 1 SIRIUSi XHS PWR V21 1 6 39 ...

Page 7: ...in the shipment your network cable included in the shipment your PC with Windows 10 older versions like Windows 7 may also work 3 1 Software installation For optimal working we recommend that you install the latest version of Dewesoft If you already have installed the older version Dewesoft is recommended that you find the newest version on the website under Support Downloads DewesoftX section You...

Page 8: ...tions are described in the following chapters 3 2 1 Standalone unit connection Image 2 Connection of SIRIUSi XHS PWR standalone device to PC List of required accessories Function Dewesoft order code Power supply PS 120 L1B2f default L1B2f BAN 3m Ethernet Power Junction ETH POWER JUNCTION Power Data L1B8m L1B8f 3m Ethernet Connection to PC RJ45 CAT7 3m SIRIUSi XHS PWR V21 1 8 39 ...

Page 9: ... 3 Connection of multiple SIRIUSi XHS PWR units to PC using PoE List of required accessories Function Dewesoft order code Power supply PS 120 L1B2f default L1B2f BAN 3m Switch DS PWR SWITCH4 Power Data L1B8m L1B8f 3m Ethernet Connection to PC RJ45 CAT7 3m SIRIUSi XHS PWR V21 1 9 39 ...

Page 10: ... SIRIUSi XHS PWR has the default IP address 192 168 10 1 Your network adapter should be set to IP 192 168 10 x where x is number from 2 255 Subnet mask 255 255 255 0 3 2 3 1 Troubleshooting If Dewesoft doesn t detect your devices you should try pinging them via command prompt In command prompt write ping IP replace IP with IP that is set on your device The result should be something like this Imag...

Page 11: ... XHS PWR devices have static IP When adding a new device open DewesoftX and go to Options Settings as shown in Image 5 Click on the Options button at the top right and then on the Settings item in the pop up to open the DewesoftX settings dialogue Image 5 Settings SIRIUSi XHS PWR V21 1 11 39 ...

Page 12: ...dding a new XHS device is done by clicking this will show the Add device window where you can find a Real time controller Sirius XHS is an RT device so you should add it by clicking on RT Device If you want to use two devices you should add two SIRIUSi XHS PWR V21 1 12 39 ...

Page 13: ...E MANUAL Image 7 Adding RT device Support of RT devices is still an Experimental feature If you do not see this option when adding a device the option needs to be enabled under Advanced Experimental settings SIRIUSi XHS PWR V21 1 13 39 ...

Page 14: ...SIRIUSi XHS PWR TECHNICAL REFERENCE MANUAL Image 8 Enable experimental feature After that you will see a new Sirius XHS or Dewesoft RT connection in the device tree SIRIUSi XHS PWR V21 1 14 39 ...

Page 15: ...HS PWR TECHNICAL REFERENCE MANUAL Image 9 Two RT devices If the text by the device is disconnected you should click on the device Dewesoft RT Connection set the correct IP and refresh SIRIUSi XHS PWR V21 1 15 39 ...

Page 16: ...SIRIUSi XHS PWR TECHNICAL REFERENCE MANUAL Image 10 Setting IP If everything is set correctly both devices should be detected as Sirius XHS devices SIRIUSi XHS PWR V21 1 16 39 ...

Page 17: ...iew Before measurement you need to set synchronization This is done by selecting Local system and selecting time source as External External Clock provider as PTP and Dewesoft DAQ Devices Clock slave as PTP Image 12 Setting synchronization SIRIUSi XHS PWR V21 1 17 39 ...

Page 18: ...ate will be set for all connected SIRIUSi XHS PWR units of course only up to the max sampling rate of the individual units In channel setup mode you can set the wanted sample rate range etc and select channels you want to measure Image 13 Channel setup 3 3 Simple Measurement This chapter describes measurement basics how to configure SIRIUSi XHS PWR and gives some details on the measurement setup 3...

Page 19: ... we will also set the other channels to the used Then you can click into the selected region to toggle Used Unused for all channels at once The selected channels will also be highlighted in the small preview image of the device When you press the Setup button of a channel the column at the right edge of the channel table not shown in this screen shot you can change all the settings of the channel ...

Page 20: ...en switching to Measure mode the data will not be stored automatically In measure mode you can have several measurement screens DewesoftX will create 2 default screens Recorder and Custom but you can also create new screens or change the widgets of the existing screens as you like The most important sections of the Measure mode Recorder widget displays all your measurement channels You can use the...

Page 21: ...elected channel of the data file Now you can use the cursors to analyse your data zoom in and out of the data click Offline math to add computations based on your data etc You can also change the design of your measurement screens print reports based on your data and export the data to other file formats for further analysis 3 4 Advanced configuration Note that the DewesoftX launcher has already d...

Page 22: ...tion Drivers Copy the file into the Firmwares folder of your Dewesoft installation e g D DewesoftX System X3 Firmwares Connect the Dewesoft instrument to the PC and run Dewesoft X3 Go to settings under the Update tab Image 19 Firmware update If the firmware package isn t selected select it by pressing the button and find the folder with the firmware file in it SIRIUSi XHS PWR V21 1 22 39 ...

Page 23: ... new license registration The registration can be made online 2 or offline by importing an offline license 5 in case the system doesn t have an internet connection Offline license can be pre registered on a different PC with the internet connection If needed the license can also be written on the actual device 5 Active and embedded licenses are seen under Active licenses tab 5 If the license is re...

Page 24: ...e installation restart now Make sure that you have started DewesoftX version X3 SP12 or higher Make sure that the external power supply is connected and okay Disconnect the network cable and reconnect it If this does not work try to connect the network cable to another Ethernet port of your PC Try to restart DewesoftX Try to restart the PC SIRIUSi XHS PWR V21 1 24 39 ...

Page 25: ...ice ever with Hybrid ADC technology capable of doing both high bandwidth transient recording and very high dynamic alias free acquisition software selectable per channel Modern interfaces and protocols allow open and flexible connectivity Image 21 SIRIUSi XHS 1xHV1xDCCT device SIRIUSi XHS PWR V21 1 25 39 ...

Page 26: ... UA industry standard protocol in parallel the data is available over XCP protocol allowing connection to ECU calibration software packages HIGH ISOLATION High channel to channel and channel to ground isolation prevents damage to the systems from excessive voltage and avoids ground loops EXTREME CONDITIONS SIRIUSi XHS 1xHV 1xDCCT comes in ruggedized chassis and can withstand the harshest environme...

Page 27: ...ct for sound vibration and general data recording applications Such acquisition mode is typically in Sigma Delta ADCs Usually you would need two totally separate devices for the above mentioned applications But on SIRIUS XHS you can select channel per channel depending on the application the appropriate mode of ADC operation 4 1 2 Perfect synchronization If you mix channels from Sigma Delta and SA...

Page 28: ... 01 gain linearity this device is perfect for direct connection to the in vehicle high current lines Zero flux transducer Measurement of residual current in core High accuracy High bandwidth Low noise Temperature stability Low power consumption 4 1 4 E mobility power device The SIRIUS XHS PWR device is well suited for in vehicle measurements In built patented DC CT current transducer allows very p...

Page 29: ...ft software will automatically calculate and store not only raw data from the voltage and current transducers but also all the power parameters P Q S D Cos φ power factor P Q cos φ for each harmonic and other relevant power parameters Each parameter can visually be displayed in a time recorder digital or analog display Using a computer graphics card as a multi threaded calculation platform the Dew...

Page 30: ... 0 1 of reading 0 05 of range Up to 100 kHz 4 of reading 0 1 of range Up to 1000 kHz 5 of reading 0 5 of range Noise floor Typ Sample rate Range 2000 V 1000 V 400 V 200 V 15 MS s 88 dB 87 dB 85 dB 81 dB 1 MS s 97 dB 94 dB 89 dB 83 dB 100 kS s 108 dB 107 dB 101 dB 96 dB 10 kS s 118 dB 117 dB 111 dB 106 dB CMR Typ Min 101 dB 88 dB 50 Hz 75 dB 68 dB 400 Hz Gain Drift typ 40ppm K max 65 ppm K Offset D...

Page 31: ...5 A 198 A 158 A Rated AC current 206 A 173 A 140 A 111 A General specifications Power Power Supply 9 60 V DC PoE RJ45 Lemo 1T 8 pin optional Power consumption Typ 15 W Max 25 W Environmental Operating Temperature 20 to 70 C Storage Temperature 40 to 85 C IP rating IP67 Shock Vibration EN 60068 2 6 2008 Environmental testing Part 2 6 Tests Test Fc Vibration sinusoidal EN 60068 2 27 2009 Environment...

Page 32: ...ange Up to 1000 kHz 5 of reading 0 5 of range Noise floor Typ Sample rate Range 2000 V 1000 V 400 V 200 V 15 MS s 88 dB 87 dB 85 dB 81 dB 1 MS s 97 dB 94 dB 89 dB 83 dB 100 kS s 108 dB 107 dB 101 dB 96 dB 10 kS s 118 dB 117 dB 111 dB 106 dB CMR Typ Min 101 dB 88 dB 50 Hz 75 dB 68 dB 400 Hz Gain Drift typ 40ppm K max 65 ppm K Offset Drift typ 0 5 mV K 1 ppm of range K Gain Linearity 0 01 Input Coup...

Page 33: ...cifications Power Power Supply 9 60 V DC PoE RJ45 Lemo 1T 8 pin optional Power consumption Typ 15 W Max 21 W Environmental Operating Temperature 20 to 70 C Storage Temperature 40 to 85 C IP rating IP67 Shock Vibration EN 60068 2 6 2008 Environmental testing Part 2 6 Tests Test Fc Vibration sinusoidal EN 60068 2 27 2009 Environmental testing Part 2 27 Tests Test Ea and guidance Shock Interfaces Eth...

Page 34: ...SIRIUSi XHS PWR TECHNICAL REFERENCE MANUAL 5 2 Dimensions 5 2 1 SIRIUSi XHS 1xHV 1xDCCT 1000A Technical drawing Image 22 SIRIUSi XHS 1xHV 1xDCCT 1000A dimensions SIRIUSi XHS PWR V21 1 34 39 ...

Page 35: ...SIRIUSi XHS PWR TECHNICAL REFERENCE MANUAL 5 2 2 SIRIUSi XHS 1xHV 1xDCCT 250A Technical drawing Image 23 SIRIUSi XHS 1xHV 1xDCCT 250A dimensions SIRIUSi XHS PWR V21 1 35 39 ...

Page 36: ...ystem is improperly handled at its end of life Please recycle this product in an appropriate way to avoid an unnecessary pollution of the environment and to keep natural resources This symbol indicates that this system complies with the European Union s requirements according to Directive 2002 96 EC on waste electrical and electronic equipment WEEE Please find further information about recycling o...

Page 37: ...ent needs to be calibrated at regular intervals We recommend annual calibration Before your Dewesoft data acquisition system is delivered it is calibrated Detailed calibration reports for your Dewesoft system can be requested We retain them for at least one year after system delivery 7 3 Support Dewesoft has a team of people ready to assist you if you have any questions or any technical difficulti...

Page 38: ...s and we take care that all key products and technologies are registered as trademarks all over the world The Dewesoft name is a registered trademark Product families KRYPTON SIRIUS DSI DS NET IOLITE and technologies DualCoreADC SuperCounter GrandView are registered trademarks as well When used as the logo or as part of any graphic material the registered trademark sign is used as a part of the lo...

Page 39: ...NICAL REFERENCE MANUAL 7 8 Documentation version history Version Date Notes V20 1 17 09 2020 Initial document version V21 1 26 06 2021 Updated Safety General product information and instructions SIRIUSi XHS PWR V21 1 39 39 ...