5 Specifications HW v1.3
Parameter
Value
Unit
Power supply Input Voltage
10 … 26
V
Power supply Input Current Limit
6
A
Control Input Voltage range (Analog
mode)
0 … 10
V
Control Input Voltage levels (PWM
mode)
TTL (3,3V or 5V)
Control Input Frequency max (PWM
mode)
5
kHz
Tacho Output Voltage levels
TTL (3,3V)
Default Tacho resolution
18
PPR
Left Encoder
1024
P/R
Right Encoder
360
P/R
6 User interface FW v1.9
After power-up, the Main Menu is shown. Select one of the following modes:
1.
MANUAL
2.
RAMP
3.
ANALOG
4.
PWM IN
6.1 Manual mode
●
Set output voltage to some low value. Enable motor by holding RUN_SW for 1sec. ON is displayed.
●
Disable motor by pressing RUN_SW shortly. OFF is displayed.
●
Set desired motor voltage with encoder, range 0,00…6,00V steps 0,10V.
●
Motor speed is shown in RPM, should use 18 PPR tacho wheel for correct reading.
●
Check Voltage needed for desired RPM. Depends on bearing wear and other factors. Approx:
VIBRO KIT V20-1
22/29