SyStem SetuP

19

DEWE3-A4 • Technical reference • Printing version 1.0.2 • March 17, 2021

DIGITAL modules    

Channels Sample rate 

per channel

Resolution Isolation

Features

TRION-CAN

4

1 MBit

-

yes

D-SUB

TRION-ARINC

-

4 or 16

-

-

no

Decoding of 

ARINC 429 

signals, export of 

decoded signals

TRION-MIL1533

-

1 or 4

-

-

no

Decoding of 

MIL-STD 1553 

signals, export of 

decoded signals

TRION-Ether

-

CAT-1-SLAVE

100

500 S/s

-

no

Measurement 

data output

Tab. 4: TRION digital modules

Power modules

POWER modules

Channels Sample rate 

per channel

Resolution Isolation

Connector type

TRION3

-1810M-POWER

1) 2)

V

1000

 

(4 U / 4 I)

10 MS/s

18 bit

yes

Safety banana, 

D-SUB

TRION-1820-POWER

1) 2)

V

1000

 

(4 U / 4 I)

2 MS/s

18 bit

yes

Safety banana, 

D-SUB

Tab. 5: TRION/TRION3 power modules

1) Some versions of this module occupy 2 TRION slots.

 

2) CAT III 1000 V only applicable for 1000 V inputs; SUB-600V has CAT II 600 V / CAT III 300 V

Analog output modules

ANALOG OUTPUT modules

Channels Sample rate 

per channel

Resolution Isolation

Connector type

TRION3

-1820-MULTI-AOUT

1)

IN 8

 

OUT 8

IN 2 MS/s

 

OUT 2.5 MS/s

IN 24-bit

 

OUT 32-bit

IN yes

 

OUT yes

IN Lemo 0B

 

OUT DSUB, BNC

Tab. 6: TRION3 analog output modules

1) Some versions of this module occupy 2 TRION slots.

INFORMATION

The TRION-TIMING module has to be installed in the STAR-slot for TRION modules. For further informa

-

tion regarding the STAR-slot for TRION modules refer to the TRION series modules technical reference 

manual.

INFORMATION

Some digital modules (e.g. TRION-M1553) require additional -12 VDC voltage which is not supported 

with DC powered DEWE3 instruments by default. Ask your local dealer or factory for more information.

Summary of Contents for DEWE3-A4

Page 1: ...pply you with accurate complete and reproducible measurement results for your decision making Look forward to the easy handling and the flexible and modular use of your DEWETRON product and draw upon more than 30 years of DEWETRON ex pertise in measurement engineering ISO9001 EN ISO 14001 THE MEASURABLE DIFFERENCE ...

Page 2: ... protected by copyright All rights are reserved Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws All trademarks and registered trademarks are acknowledged to be the property of their owners ...

Page 3: ...te training This documentation contains operating as well as safety and care instructions that must be observed by the user Fault less operation can only be guaranteed by observing these instructions Intended use A DEWETRON DEWE3 A4 is an all in one instrument and the high speed solution of the popular previous generation DEWE2 A4 The instrument offers 4 slots for user exchangeable TRION TRION3 se...

Page 4: ...TRION SYNC BUS 7 Power on off switch 8 Chassis terminal 9 EPAD2 interface connector 10 Dual LAN GBit connectors 11 WLAN antenna 12 USB 3 0 interface connectors 13 HDMI connectors 14 RS 232 interface connector COM1 15 SSD drive bay for operating system and application software on backside 16 Power supply input connector EGJ 2B 302 17 Power supply output for accessories 12 VDC LEMO EGG 1B 302 ...

Page 5: ...ices 12 Symbols 12 System setup 13 Key facts 13 System specifications 13 Dimensions 14 Connections and ports 15 DEWE3 TRION TRION3 hardware compatibility 17 TRION series modules overview 17 Analog modules 17 Digital modules 18 Power modules 19 Analog output modules 19 Installing a TRION module 20 Power supply 21 Internal DC power supply 21 External AC DC power supply 21 DW2 PS DC BUFFER option 22 ...

Page 6: ...TABLE OF CONTENTS 6 Notes ...

Page 7: ...outside the scope of the 2011 65 EU RoHS Directive This product is known to contain lead Problematic network stacks Often intrusive IT software or network processes can interfere with the primary function of the DEWETRON system to record data Therefore we recommend strongly against the installation of IT MIS software and running their process es on any DEWETRON data acquisition system and cannot g...

Page 8: ...connection with the furnishing of this document or the use of the information in this document Printing history Refer to the page bottom for printing version Copyright DEWETRON GmbH This document contains information which is protected by copyright All rights are reserved Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright law...

Page 9: ...en exposed to long storage in adverse environmental the system has been exposed to heavy shipment strain The warranty is void if damages caused by disregarding this manual For consequential damages NO liability will be assumed The warranty is void if damages to property or persons caused by improper use or disregarding the safety instruc tions Unauthorized changing or rebuilding the system is proh...

Page 10: ...stem must be connected and operated to an earthed wall socket at the AC mains power supply only except for DC systems DO NOT touch any exposed connectors or components if they are live wired The use of metal bare wires is not allowed There is a risk of short circuits and fire hazard The assembly of the system is equivalent to protection class I For power supply only the correct power socket of the...

Page 11: ...in this manual EN 61326 3 1 2008 IEC 61326 1 applies to this part of IEC 61326 but is limited to systems and equipment for industrial applications intend ed to perform safety functions as defined in IEC 61508 with SIL 1 3 The electromagnetic environments encompassed by this product family standard are industrial both indoor and out door as described for industrial locations in IEC 61000 6 2 or def...

Page 12: ...wn on the product refer to the technical reference manual ISO 7000 4034 2004 01 Indicates hazardous voltages Observe precautions for handling electrostatic sensitive devices Indicates the chassis terminal IEC 60417 5020 2002 10 Direct current IEC 60417 5031 2002 10 Alternate current IEC 60417 5032 2002 10 Both direct and alternating current IEC 60417 5033 2002 10 3 Three phase alternating current ...

Page 13: ...AD3 via TRION CAN Quasi static channel expansion EPAD2 interface connector CPAD2 via TRION CAN Main system System bandwidth 500 MB s Data storage 1 TB SSD PCIe dedicated for data storage 400 MB s 256 GB SSD for operating system and application software Display 13 wide screen 1920 x 1080 px Power supply input DW2 PS PC BUFFER optional Rated input voltage Internal UPS battery for 5 min dep on system...

Page 14: ...3 m s 30 minutes direction Shocktests2 EN 60068 2 27 Pulse form Acceleration amplitude Duration Direction Half sine 30 g 11 ms 3 bumps each direction 6 directions in total Tab 1 System specifications DEWE3 A4 1 Depending on installed TRION series modules Refer to the TRION technical reference manual 2 Tested with SSD Dimensions 316 253 219 61 5 69 61 5 48 24 16 5 9 5 124 3 3 15 5 230 5 295 5 3 3 1...

Page 15: ...ers 5 TRION TRION3 series module slots 4 slots for TRION TRION3 series modules For more information about the various modules refer to TRION series modules overview on page 19 The DEWE3 A4 supports all modules For details see Hardware compatibilty on page 19 6 TRION SYNC BUS The TRION SYNC BUS allows an easy highspeed channel expansion with TRIONet front ends or distributed high channel count syst...

Page 16: ...onfigured as standard RS 232 interface COM 1 and can be used for mouse or other peripheral units Pin assignment 1 DCD Data Carrier Detector 2 RD Received Data 3 TD Transmitted Data 4 DTR Data Terminal Ready 5 GND Ground 6 DSR Data Set Ready 7 RTS Request To Send 8 CTS Clear To Send 9 RI Ring Indicator 15 SSD drive bay The DEWE3 A4 equipped with a drive bay for a preinstalled 1 TB PCIe SSD 400 MB s...

Page 17: ... feature a PXIe hybrid backplane and supports any TRION3 series modules It is also backward compatible and does support all TRION series modules from previous generation The illustrations below will give you an overview of the hardware compatibility and its limitations module e g TRION3 1850 MULTI DEWE3 A4 max data throughput up to 500 M s TRION series module e g TRION 1603 LV BNC Data troughput u...

Page 18: ...0 MSI CB16 16 or 32 200 kS s 100 kS s 18 bit 24 bit no D SUB TRION 1600 dLV V 1000 00 MSI CB16 16 or 32 20 kS s 16 bit no D SUB Tab 3 TRION TRION3 analog modules 1 Some versions of this module occupy 2 TRION slots 2 CAT III 1000 V only applicable for 1000 V inputs SUB 600V has CAT II 600 V CAT III 300 V Digital modules DIGITAL modules Channels Sample rate per channel Resolution Isolation Features ...

Page 19: ... TRION3 power modules 1 Some versions of this module occupy 2 TRION slots 2 CAT III 1000 V only applicable for 1000 V inputs SUB 600V has CAT II 600 V CAT III 300 V Analog output modules ANALOG OUTPUT modules Channels Sample rate per channel Resolution Isolation Connector type TRION3 1820 MULTI AOUT1 IN 8 OUT 8 IN 2 MS s OUT 2 5 MS s IN 24 bit OUT 32 bit IN yes OUT yes IN Lemo 0B OUT DSUB BNC Tab ...

Page 20: ...t 4 Remove the filler panel of an unused TRION TRION3 peripheral or STAR slot 5 Place the module edges of the TRION TRION3 module into the module guide at the top and bottom of the chassis 6 Insert the TRION TRION3 module to the rear of the chassis until a resistance appears 7 Pull up on the injector ejector handle to latch the device 8 Secure the installed TRION front panel to the chassis by usin...

Page 21: ...supply Input Rated input voltage Input frequency Power Connector 11 32 VDC max 10 36 VDC DC 210 W 2 pin male LEMO EGJ 2B 302 Tab 7 Specifications internal 210 W DC power supply External AC DC power supply 250 W AC DC power supply Input Rated input voltage Input frequency Current 100 240 VAC max 90 264 VAC 50 60 Hz max 3 A Output Voltage Current Output power 24 VDC 10 42 A max load max 250 W Tab 8 ...

Page 22: ...onization The TRION SYNC BUS SYNC I O SYNC OUT is used to synchronize two or more DEWE3 systems with up to 100 m distance between each node The TRION SYNC BUS consists of two RJ 45 sockets One socket being a synchronization OUT whilst the other one could either be used as synchronization IN or OUT Depending on the usage of the SYNC I O input or output the LED indicates if the system clock is avail...

Page 23: ...tion With this option the DEWE3 A4 can operate synchronized with other measurement devices with an absolute time reference PTP sync IRIG sync Fig 8 PTP sync IRIG sync PTP Sync Generator IRIG Sync Generator PTP SYNC IRIG SYNC Synchronization via PTP Synchronization via IRIG DEWE2 M7s with TRION TIMING module IEEE 1588 PTP enabled switch IEEE 1588 PTP enabled switch DEWE3 A4 with TRION TIMING module...

Page 24: ...System setup 24 GPS sync DEWE3 A4 with TRION TIMING V3 module DEWE3 PA8 with TRION VGPS or TRION TIMING V3 module Fig 9 GPS sync ...

Page 25: ...ility guidance Also keep in mind that the use of any antivirus or other security software may slow down your system and may cause data loss Software updates NOTICE The system BIOS is protected by password Any change in the BIOS may cause a system crash When the system is booting do not press ESC button on keyboard This may clear the BIOS settings and cause system faults Any change in the file stru...

Page 26: ...WETRON Inc HQ USA 2850 South County Trail Unit 1 East Greenwich RI 02818 USA Tel Fax E Mail Web 43 316 3070 43 316 3070 90 support dewetron com http www dewetron com Tel Toll free Fax Email Web 1 401 284 3750 1 866 598 3393 1 401 284 3750 support dewetron com http www dewetron com The telephone hotline is available Monday to Friday between 08 00 and 17 00 CET GMT 1 00 The telephone hotline is avai...

Page 27: ... proper operation in future For information regarding service and repairs contact your local distribu tor first or DEWETRON directly INFORMATION Any spare parts screws backplanes cables etc must be obtained from DEWETRON only Maintenance and service 27 DEWE3 A4 Technical reference Printing version 1 0 2 March 17 2021 ...

Page 28: ...ouncil of 26 February 2014 on the harmo nization of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits 2014 30 EU Directive of the European Parliament and of the Council of 26 February 2014 on the harmo nisation of the laws of the Member States relating to electromagnetic compatibility recast The accor...

Page 29: ...Certificate of conformity 30 Notes ...

Page 30: ...IS Management information system PTP Precision time protocol SIL Safety integrity level STAR slot TRION slot for clock distribution when using TIMING modules SSD Solid state drive WEEE Waste of electrical and electronic equipment European Community Directive 2002 96 EC Glossary 31 DEWE3 A4 Technical reference Printing version 1 0 2 March 17 2021 ...

Page 31: ...Glossary 32 ...

Reviews: