Unsealed self-rescuers (opened, damaged) where oxygen-containing product has direct contact
with air, shall be disposed in accordance with Section 14 «DISPOSAL». It is forbidden
to leave unsealed (opened) self-rescuers in the mine.
DANGER!
If the self-rescuer is damaged, the oxygen-containing product can cause ignition of coal, wood or other
flammable materials.
The notified body Eurofins Product Testing Italy S.r.l., Via Courgnè, n.21, 10156 TORINO, ITALY (No.
0477) performed the EU type-examination (Module B) and issued the EU type-examination certificate
№ EPT 0477.PPE.21/4588.
The PPE is subject to the conformity assessment procedure to type based on internal production
control plus supervised product checks at random intervals (Module C2) under surveillance of the
notified body Eurofins Product Testing Italy S.r.l., Via Courgnè, n.21, 10156 TORINO, ITALY (No. 0477).
3. TECHNICAL DATA
The key specifications of the CARBO self-rescuer are listed in Table 1.
Table 1 – Key specifications of the self-rescuer
Parameter name
Parameter value
Rated duration
1
in accordance with EN 13794:2002 and AS/NZS
1716:2012 at lung ventilation, not less:
- 10 l/min (waiting for help)
- 35 l/min (normal walking)
180 min
60 min
Breathing resistance (to inhalation or exhalation) during operation, max
0,75 kPa
Temperature of the inhaled gas, not more
50
0
С
Volume of oxygen in the inhaled gas during the rated duration, not less
21%
2
Maximum volume fraction of carbon dioxide in the inhaled gas, not more
3%
Average volume fraction of carbon dioxide in the inhaled gas during the
rated duration, not more
1,5%
Volume of breathing bag, not less
6 L
Overall dimensions
(without waist and shoulder straps or pouch), not more:
- width
- height
- depth
215 mm
227 mm
106 mm
Weight
2,9
-0,1
kg
Operating temperature
from -5 to +60
о
С
Relative humidity (at +35 °C) during operation and storage
up to 100%
Information about service life, shelf life and warranty period is indicated in the Data Sheet which
is supplied with each SCSR.
1. Rated duration may vary under the escape conditions depending on physical activity and physiological
peculiarities of the user.
2. Short-time decrease of oxygen volume fraction in the inhaled gas down to 17% is allowed during the first two
minutes after the self-rescuer activation.
Summary of Contents for CARBO S-60MP1-ISG-AUENAU-BKO
Page 3: ...CARBO USER manual EN ...
Page 24: ......
Page 25: ...CARBO INSTRUKCJA obsługi PL ...
Page 46: ......
Page 47: ...CARBO KULLANIM Kılavuzu TR ...
Page 68: ......
Page 69: ...CARBO MANUAL de usuario ES ...
Page 90: ......
Page 91: ......
Page 92: ...MS1 MUMU 032022 ...