Р-70i
DEZEGA
18
Harness system
If the harness system of the breathing apparatus is dismounted during maintenance, then:
•
Pass the upper strap loops on shoulder shock absorbers through the holes located on the body
of the breathing apparatus at the top. Fix the loops with fixing plates.
•
Insert the lower ends of the shoulder shock absorber straps into the hinged metal loops in the
lower part of the breathing apparatus body.
•
Fasten the straps to the tension buckles located at the bottom of
shock-absorbing pads. Mount the waist plate on the waist shock absorber. Attach buckles on
the ends of the straps.
•
Fill in the swivel tab on the waist plate into the hole on the body. The choice of the desired
hole on the case is determined by the anthropometric data of the user. To do this, insert the
tab into the hole and push it into the body until it stops. Without releasing it, turn it a quarter
of a turn so that the spring tab on the plate fits into the corresponding slot on the casing
of the breathing apparatus.
Oxygen distribution unit
If the oxygen distribution unit is dismounted during breathing apparatus disassembly:
•
Install the unit into the protective case of the breathing apparatus.
•
Tighten in the captive screw.
•
Connect the high-pressure sensor connector with an internal electronic module of the
communication device.
Electronic measuring device (EMD)
If EMD is dismounted during breathing apparatus disassembly:
•
Insert the communication device inside the body of the P-70і breathing apparatus.
•
Connect control unit and communication device.