- 4 -
1.
Installation
(1)
The recommended erection height is 2.5-3 meters
(2)
The recommended distance to the subjects is 3 meters
(3)
The thermal lens must be adjusted according to the environment.
(4)
Avoid strong light in the installation environment.
(5)
Outdoor ground temperature would affected by weather, please avoid capturing the
outdoor ground.
(6)
Thermal camera is unable to capture subjects blocked by glass.
(7)
Subjects shouldn’t be set under the air-conditioner, and avoid reflective objects,
reflective objects, and hot objects around, such as: stainless steel, mirror, glass,
electrical appliances, hot food, etc.