Flight manual DG-800S
7.13. 2
Oxygen system
Oxygen bottle installation
Max. size of oxygen bottle is 4 l capacity with diameter 100 mm (3.94
in.).
The bottle must be fixed at its neck with a bracket part No. Z 14.
Installation of the oxygen equipment
To ensure a safe installation ask for an installation instruction.
For the installation of the Dräger Höhenatmer E 20088 you will find an
installation plan 6EP18 in the maintenance manual.
7.13.3
ELT Emergency Locator Transmitter
To ensure a safe installation ask for an installation instruction.
For the model ACK E-01 you will find an installation plan 8EP38 in the
maintenance manual.
Caution:
Concerning 7.13.2 and 7.13.3
The installation has to be accomplished by the aircraft manufacturer or by an
approved service station and to be inspected and to be entered in the aircraft log
book by a licensed inspector.
7.13.4
Battery in the fin
(Option)
Only the factory supplied battery (part No. Z 07, mass 4.3 kg (9.5 lbs.))
is allowed to be used. If the pilot mass is less than the min. cockpit load,
the battery may be removed from the fin and another battery installed in
the baggage compartment. This lowers the min. cockpit load by 20 kg
(44 lbs.).
By looking through a Plexiglas window in the left fin surface it can be
checked, if the battery is installed.
To connect the fin-battery to the electrical system, the wiring coming
from the instrument panel is to be plugged in the socket located at the
rear wall of the baggage compartment.
Issued: April 1997 7.10