background image

Preliminary checks

Take the PRESFLO

®

 out of 

the packaging and check the 
following:
- check for damage, 
- check the RATINGS corre-
spond with those required, 
- that the cable bushings and 
screws are in place,
- that PRESFLO

®

’s inlets and 

outlets are clean and free of 
any packaging materials,
- that the check valve moves 
smoothly.

Hydraulic connections

the  joint  in  two  pieces  allows 
rapid  connection  to  the  system.

 

DO  NOT  apply  sealant  inside  the 
2-piece  joint  because  it  already 
has an internal o-ring.

Orientation

PRESFLO

®

 can be 

installed at any angle 
depending on the 
flow direction, as 
indicated in the diagrams.

Position

PRESFLO

®

 can either be fitted 

directly to the pump outlet or 
anywhere along the delivery 
line. Never install taps between 
the pump and PRESFLO

®

. Do 

not install a non-return valve 
between PRESFLO

®

 and the 

taps, meanwhile it is possible, 
although not necessary, to in-
stall a non-return valve on the 
suction piping of the pump.

Installation

Red =

Blue =

Yellow = 

Attention

The pressure applied 

by the water column above 
PRESFLO

®

 must not exceed 

that of the pump start-up 
pressure (Pm). If, for example, 
PRESFLO

®

 is installed at a 

height 15 m (50 ft) below that 
of the highest tap in the sy-
stem, the pressure detected by 
PRESFLO

®

 will be approxima-

tely 1.5 bar (22 psi). A model 
with Pm = 2.2 bar (32 psi) 
should, therefore, be installed 
in order to guarantee that the 
pump is started when a tap is 
turned on.

Attention

The maximum pressure 

produced by the pump must be 
at least 1 bar (15 psi) higher 
than the start-up pressure 
(Pm). If the pressure produced 
by the pump is too low, 
PRESFLO

®

 will stop the pump 

and indicate a ‘dry running’ 
error message.

First start-up

Priming the pump

For instructions on how to 
prime (fill) the pump, see the 
pump manual.

Attention

PRESFLO

®

 is fitted with a 

check valve: do not use the 
PRESFLO

®

’s outlet to fill the 

pump for priming.

Switching the pump on  

The red (Power On) LED lights 
up; PRESFLO

®

 instantly detects 

that there is no pressure within 
the system and 
starts the pump 
(the green 
‘Pump On’ LED lights up).
If, within 15 seconds of starting 
up, PRESFLO

®

 

does 
not detect the 
correct priming of 
the pump, it stops the pump 
and indicates a ‘dry running’ 
error message.
 

Attention

When the pump is star-
ted for the first time, it 
may have to be run for 

longer in order to complete the 
priming procedure.

Press the 
STOP/RESTART 
button 

to restart the 
pump and 
complete the 
priming procedure.

Motor

Line

Nut

Seal

Cable bushing

Attention!

 The cable 

bushings and circuit board 
cover must be properly 
assembled and secured 
in order to guarantee IP 
65 grade protection of the 
electrical components. 

Electrical con-
nections

The electrical 
connections 
should be made 
as indicated in the 
diagram which 
can also be found 
on the inside of 
the circuit cover.

NOTE 1 - DRY RUN PROTECTION 

=  there is no flow and the 

pressure is lower than that of the pump start-up pressure (Pm). 
It occurs when there is no water. After 15 seconds PRESFLO

®

 

stops the pump and indicates an ERROR message. PRESFLO

®

 

AUTOMATICALLY tries to resume NORMAL SERVICE at intervals 
of increasing time (1, 15, 30, 60 minutes and successively once 
every hour - 24 H for AU/NZ -). If PRESFLO

®

 detects any pressure 

and/or flow, NORMAL SERVICE is resumed, otherwise, the pump is 
stopped again until the next attempt is made. A MANUAL attempt 
to resume NORMAL SERVICE can be made at any time. 

NOTE 2 - EXCESSIVE STARTS 

= the repeated stopping and 

starting of the pump at intervals of less than 1 minute from each 
other. This occurs when the flow rate is less than 2 litres/min. This 
may cause damage to the pump. In event of small leaks (dripping), 

PRESFLO

®

’s water accumulator guarantees that the pump starts/

stops at time intervals of over 1 minute (less than 60 starts/hour) 
and that FREQUENT START-UP errors do not occur. In the event of 
a major leak or extended use at excessively low flow rates (less 
than 2 litres/min), the pump may be started/stopped as often as 
once every few seconds, putting the pump at risk of damage. In 
this case, after about 40 minutes, PRESFLO

®

 stops the pump for 

the following 30 minutes (in order to let it cool down) and indicates 
an ERROR message. If the time interval between the starts-stops 
is more than 10 seconds (and therefore poses less of a risk to the 
pump), PRESFLO

®

 will allow the pump to be used for more than 

30 minutes. Once that enough time has passed to allow the pump 
to cool down it is restarted AUTOMATICALLY. The pump may be 
restarted MANUALLY any time.

20

 m (65 ft)

12

 m  (40 ft)

 6

 m (20 ft)

Summary of Contents for PRESFLO

Page 1: ... relevant regulations DGFLOW shall not be held lia ble for any damage relating to or resulting from an improper use of the product or for any damage relating to or resulting from servicing or repairs carri ed out by unqualified personnel and or with non OEM spare parts The warranty which is valid for 24 months from the date of purchase will no longer be applicable should the product suffer damage ...

Page 2: ...mp and indicates a dry running error message Attention When the pump is star ted for the first time it may have to be run for longer in order to complete the priming procedure Press the STOP RESTART button to restart the pump and complete the priming procedure Motor Line Nut Seal Cable bushing Attention The cable bushings and circuit board cover must be properly assembled and secured in order to g...

Page 3: ...stopped and put in STAND BY To reset see point 3 If the absence of flow lasts for a few seconds the pump is stopped STAND BY NORMAL SERVICE pump during shutdown See NOTE 1 PRESFLO has detected that the pump is dry running and has therefore stopped it TEMPORARILY Press briefly the pump is started and manually and resumes NORMAL SERVICE See points 2a 2b Hold down the pump is put STAND BY For instruc...

Page 4: ...start up pressure Pm for the chosen application Relocate PRESFLO to another position Install a model with a higher start up pressure Pm Faulty electrical connections or pump out of service Check the electrical connections and that the pump is working PRESFLO STAND BY Reset PRESFLO See Operation point 3 PRESFLO in temporary shut down due to DRY RUNNING due to lack of water Wait for the automatic re...