Exploded view of spare parts

Attention

: when ordering spare 

parts, always state the position 
n° from the diagram below and 
the product code number found 
in the pressure-flow regulator 
technical data table.
1 - Circuit board cover
2 - Pressure gauge
3 - Circuit board
4 - Cable bushings
5 - Valve unit
6 - two-pieces joint with OR

Article

Version

Size

Disposal

When disposing of any 
PRESFLO

®

 parts, adhere 

to the relevant laws and 
regulations in force in 
the country in which the 
equipment is being used. 
Do not dispose of any 
polluting parts in 
the environment.

Statement of Compliance: 

we declare, under our own respon-

sibility, that the product in question is in compliance with the fol-
lowing European Directives and national implementation provisions

2014/35/CE  Low Voltage Directive
2011/65/CE  (RoHS)
2012/19/CE - 2003/108/CEE  (WEEE)
2014/30/CE  Electromagnetic Compati-
bility Directive (EMC)
EN 60730-2-6
EN 61000 6-3

Bigarello 01.06.16

DGFLOW S.r.l.
President
Stefano Concini

Problems

Signals

Possible causes

Solutions

PRESFLO

®

 

will not turn on

No power

Check the electrical connections

The pump will 
not start when 
a tap is turned on

PRESFLO

®

 model with an inadequate 

start-up pressure (Pm) for the chosen 
application.

Relocate PRESFLO

®

 to another position

Install a model with a higher start-up pressure (Pm)

Faulty electrical connections or 
pump out of service

Check the electrical connections and that the pump 
is working

PRESFLO

®

 “STAND-BY”

Reset PRESFLO

®

  (See Operation, point 3). 

PRESFLO

®

 in temporary shut down 

due to “DRY RUNNING” due to lack 
of water

Wait for the automatic restart or press START to 
restart manually (See Operation, point 4a)

Maximum pump pressure is 
insufficient

Replace the pump with one with more suitable 
characteristics

Install a model with a lower start-up pressure (Pm)

PRESFLO

®

 in temporary shut down 

due to “FREQUENT START-UP”

Wait for the automatic restart or press START to 
restart manually (See Operation, point 4b). Remove 
any cause of leakage from system or install an 
expansion tank

The pump 
delivers no or low 
pressure

Filters or pipes may be partly blocked Check the water pipes

PRESFLO

®

’s valve will not open 

completely

Check that the valve is not blocked by any foreign 
objects and clean if necessary

The pump stops 
and starts 
repeatedly

Leaks within the system (less than 
the shut-off flow rate Qa)

Check the hydraulic connections and repair any 
leaks. If a leak cannot be repaired, install an 
expansion tank

The pump will 
not stop

The flow rate is higher than the 
shut-off flow rate (Qa)

Make sure that all taps are turned off and that 
there are no leaks within the system

PRESFLO

®

’s check valve will not 

close or is damaged

Check that the valve is not blocked by any foreign 
objects and clean if necessary

= Off

= On

= Flashing

Summary of Contents for PRESFLO

Page 1: ... relevant regulations DGFLOW shall not be held lia ble for any damage relating to or resulting from an improper use of the product or for any damage relating to or resulting from servicing or repairs carri ed out by unqualified personnel and or with non OEM spare parts The warranty which is valid for 24 months from the date of purchase will no longer be applicable should the product suffer damage ...

Page 2: ...mp and indicates a dry running error message Attention When the pump is star ted for the first time it may have to be run for longer in order to complete the priming procedure Press the STOP RESTART button to restart the pump and complete the priming procedure Motor Line Nut Seal Cable bushing Attention The cable bushings and circuit board cover must be properly assembled and secured in order to g...

Page 3: ...stopped and put in STAND BY To reset see point 3 If the absence of flow lasts for a few seconds the pump is stopped STAND BY NORMAL SERVICE pump during shutdown See NOTE 1 PRESFLO has detected that the pump is dry running and has therefore stopped it TEMPORARILY Press briefly the pump is started and manually and resumes NORMAL SERVICE See points 2a 2b Hold down the pump is put STAND BY For instruc...

Page 4: ...start up pressure Pm for the chosen application Relocate PRESFLO to another position Install a model with a higher start up pressure Pm Faulty electrical connections or pump out of service Check the electrical connections and that the pump is working PRESFLO STAND BY Reset PRESFLO See Operation point 3 PRESFLO in temporary shut down due to DRY RUNNING due to lack of water Wait for the automatic re...