2. Introduction

Thank you for choosing to use the 

VENTURI

 COMPACT Negative Pressure Wound Therapy (NPWT) system from 

Direct Healthcare Group. The 

VENTURI

 COMPACT system is intended for use for patients with acute or chronic 

wounds that may be benefitted by the application of continuous or intermittent negative pressure wound therapy to 
the wound for removal of fluids, including wound exudate, irrigation fluids, and infectious materials.

NPWT is applied utilising a choice of 

VENTURI

 Wound Care Sets (supplied separately) which include a choice of 

gauze or soft foam dressing, a silicone portal drain and transparent adhesive film. Both foam and gauze Wound Care 
Sets are available in a range of sizes according to the wound type being treated.

The 

VENTURI

 COMPACT NPWT system is intended to be reusable and will benefit from careful installation and use, 

providing a long and effective service life. Please read and understand this document completely before applying 
NPWT.

3. Important Information

3.1 Intended Use

The VENTURI COMPACT NPWT system may be used:
•  to help expedite wound closure (when healing by secondary intention)
•  when preparing a wound for closure by primary intention
•  for wound management (odour control, exudate management, etc.)
Wounds which may benefit from the application of NPWT include pressure ulcers; dehisced surgical wounds; diabetic/
neuropathic foot ulcers; venous leg ulcers; post-op surgical wounds (including flaps and grafts); traumatic wounds; 
pre-op flap/graft; necrotising fasciitis; burns.

3.2 Intended Environments

The devices are intended for use by qualified healthcare professionals and lay persons in a healthcare or home 
environment.

3.3 Contraindications for Use

Do not place NPWT dressings directly in contact with exposed blood vessels, anastomotic sites, organs or nerves.
NPWT is contraindicated for patients with:
1. Malignancy in the wound
2. Untreated osteomyelitis
3. Non-enteric and unexplored fistulas
4. Wounds with difficult haemostasis
5. Necrotic tissue with eschar present
NB: After debridement of necrotic tissue and complete removal of eschar, NPWT can be used.

3.4 List of Components

Your 

VENTURI

 COMPACT NPWT system should comprise the following items - please ensure you have all of these 

before installation.
NB: Wound Care Sets are supplied separately.

•  VENTURI

 COMPACT (TG600/08) vacuum power unit

•  12V Mains adapter FW7556M/12 / VEP15US12
•  300ml Canister (supplied fitted to power unit)
•  Carry bag (may not be included in all markets)

D H G - H E A LT H C A R E . C O M

3

U S E R   M A N U A L

Summary of Contents for TG600/08F

Page 1: ...DHG HE ALTHCAR E C O M VENTURI Compact User Manual...

Page 2: ...VENTURI COMPACT DHG HEALTHCARE COM...

Page 3: ...NPWT 5 Getting Started 5 Operating the Vacuum Power Unit 5 5 Operation Guidelines 6 User Information 6 Operation Controls 7 User Selectable Functions 8 Setting Changing Power Unit Display Languages 8...

Page 4: ...Warning Refer to instruction manual booklet Medical Devices Directive 93 42 EEC Medical Device Regulation 2017 745 North America ETL listed Class II Equipment Double Insulated Do not dispose of with t...

Page 5: ...for closure by primary intention for wound management odour control exudate management etc Wounds which may benefit from the application of NPWT include pressure ulcers dehisced surgical wounds diabet...

Page 6: ...acuum power unit or power adapter on or near a heat source Never use the power adapter whilst placed on top of or near to material which is flammable or can be damaged by heat The supplied power adapt...

Page 7: ...nal s treating the wound must assess how to best use the system for an individual wound 1 Remove all packaging from the power unit and mains adapter NB The power unit internal battery may be mostly di...

Page 8: ...t and continue NPWT 7 Canisters should be replaced as required or weekly To change canister make sure power unit is in stand by mode if still running press and hold the UNLOCK button followed by the R...

Page 9: ...ower unit will then power off after 1 minute of inactivity If using mains power switch off by disconnecting power cable from power unit or turning off mains power VACUUM LEVEL Vacuum level can be adju...

Page 10: ...ey to select this function c To select the required language press and hold the THERAPY MODE button until the language is displayed Releasing the THERAPY MODE button will then set the display for the...

Page 11: ...s adequately or may interfere with device function Direct Healthcare Group recommends the use of TECcare CONTROL antimicrobial wipes and fluid to clean and decontaminate all products it supplies to he...

Page 12: ...he canister is removed both of which cancels the message and sounder and returns the power unit to stand by mode Change canister as detailed on page 6 NB The Canister Full sounder can be silenced by p...

Page 13: ...put Voltage 12V Nominal Vacuum Application Continuous default therapy or intermittent Pressure Range 10 to 180mmHg 0mmHg 20mmHg Fixed Internal Battery 3 7V 10Wh Lithium Ion Rechargeable Cell IP Rating...

Page 14: ...ion Medical electrical equipment safety and essential performance IEC 60601 1 11 Home healthcare environment 8 4 Manufacturer s Guarantee The VENTURI COMPACT power unit is covered by a 24 month manufa...

Page 15: ...e source of the interference by turning nearby or suspect equipment off and see if the interference effects stop In any such event the user is encouraged to try to correct the interference by one of t...

Page 16: ...UT 0 5 cycle At 0 45 90 135 180 225 270 and 315 Mains supply quality for the mains adapter should be that of a typical commercial and or hospital environment In the event of a mains interruption the...

Page 17: ...in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cell...

Page 18: ...nual was correct at the time of going to press However Direct Healthcare Group reserves the right to modify the specification of any product without prior notice in line with a policy of continual pro...

Page 19: ...DHG HEALTHCARE COM USER MANUAL Notes 1 7...

Page 20: ...et Swatar BKR 4013 Malta Direct Healthcare Group Ltd Withey Court Western Industrial Estate Caerphilly United Kingdom CF83 1BF T 44 0 800 043 0881 F 44 0 845 459 9832 E info directhealthcaregroup com...

Reviews: