Example of a UDI label

This is a statement that alerts the 

user to the possibility of serious 

injury or other adverse reactions 

with the use or misuse of the device

This is a statement that alerts the 

user to the possibility of a problem 

with the system associated with its 

use or misuse

Authorised Representative in the 

European Community

Caution: Federal (USA) law restricts 

this device to sale on or by the 

order of a licensed healthcare 

professional

Single use only - do not reuse

Fragile, handle with care

Keep dry

Protect from heat and radioactive 

sources

Temperature limitation

Humidity limitation

Atmospheric pressure limitation

Warning

Refer to instruction manual

 / booklet

Medical Devices Directive 93/42/EEC

Medical Device Regulation 2017/745

North America ETL listed

Class II Equipment (Double Insulated)

Do not dispose of with the normal 

household waste

Manufacturer

Date of Manufacture

Suitable for connection to type BF applied 

parts

IP: Ingress Protection
2: Protection against fingers or other 

object not greater than 80mm in length 

and 12mm in diameter
2: Protection from vertically dripping water 

when tilted to 15

o

)

Medical Device

Catalogue number

Serial number

Operating Instructions

12345
1234567890

YYYYMMDD

0 5060178 XXXXX X
YYMMDD

1234567890

IP22

WARNING

CAUTION

1. Explanation of Label Symbols and Statements

2

V E N T U R I

®

  M I N O

D H G - H E A LT H C A R E . C O M

EC REP

Note: Abbreviation:

Negative Pressure Wound Therapy

 is abbreviated to ‘

NPWT

’ throughout this document.

Summary of Contents for TG600/14

Page 1: ...DHG HEALTHC AR E C O M DHG HE ALTHCAR E C O M VENTURI MINO User Manual...

Page 2: ...VENTURI MINO DHG HEALTHCARE COM...

Page 3: ...tions and Information 4 4 How to Apply NPWT 5 Getting Started 5 Operating the Vacuum Power Unit 5 5 Operation Guidelines 6 User Information 6 Operation Controls 7 Battery Information 7 6 Care and Main...

Page 4: ...n Warning Refer to instruction manual booklet Medical Devices Directive 93 42 EEC Medical Device Regulation 2017 745 North America ETL listed Class II Equipment Double Insulated Do not dispose of with...

Page 5: ...gery Wounds which may benefit from the application of NPWT include pressure ulcers dehisced surgical wounds diabetic neuropathic foot ulcers venous leg ulcers post op surgical wounds including flaps a...

Page 6: ...near to material which is flammable or can be damaged by heat The supplied power adapters plug directly into the power source partly mitigating this issue The VENTURI MINO TG600 14 vacuum power unit...

Page 7: ...o the VENTURI MINO power unit by lining up the two parts pushing together and twisting to lock Fig 1 Remove the bung from the connector port this can be retained to cap the used canister prior to disp...

Page 8: ...ubing as above this can be reconnected to new canister and unclamped if wound dressing is not being changed Rotate canister to unlock and remove from power unit Dispose of used canister according to l...

Page 9: ...begin operation at the default pressure of 80mmHg The selected vacuum level is shown on the display screen 5 3 Battery Information A fully charged battery should operate the power unit continuously fo...

Page 10: ...ocial care facilities TECcare CONTROL products provide class leading broad spectrum high level disinfection with an exceptional safety profile Being pH neutral TECcare CONTROL can be universally used...

Page 11: ...heck that low flow is not caused by pinched or bent tubing If exudate is pooling in the wound bed the dressing should be changed This alert will self cancel after 5 minutes and will re occur if the co...

Page 12: ...above mains adapter is considered part of the ME equipment The VENTURI MINO power unit must only be used with the specific external power adapter as supplied by Direct Healthcare Group EXPECTED SERVIC...

Page 13: ...ntinuous resets Try to ascertain the source of the interference by turning nearby or suspect equipment off and see if the interference effects stop In any such event the user is encouraged to try to c...

Page 14: ...UT 0 5 cycle At 0 45 90 135 180 225 270 and 315 Mains supply quality for the mains adapter should be that of a typical commercial and or hospital environment In the event of a mains interruption the V...

Page 15: ...rs such as base stations for radio cellular cordless telephones and land mobile radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electroma...

Page 16: ...et Swatar BKR 4013 Malta Direct Healthcare Group Ltd Withey Court Western Industrial Estate Caerphilly United Kingdom CF83 1BF T 44 0 800 043 0881 F 44 0 845 459 9832 E info directhealthcaregroup com...

Reviews: