40
DHOLLANDIA
16
COMMISSIONING & QUALITY CONTROL
•
Finish the liftgate in accordance with local regulations.
•
Execute all functions min. 5 times to ensure the liftgate functions correctly. Pay special attention to:
1.
Smooth and quiet operation through the full range of motion of the platform
2.
Auto tilt at ground level
3.
Correct alignment of the open platform flush with the vehicle floor
4.
Correct stowage of the liftgate in its travel position.
•
Make sure that the liftgate will be clearly visible in surrounding traffic [Figure 16.1]:
1.
Apply the RD/WH conspicuity tape on both sides of the platform.
2.
Fit the platform flags to the underside of the flip-over point.
3.
If applicable: connect the flashing platform lights (if not prewired) and verify their function.
•
Lay a straight profile over lengthwise across the platform. Verify and make sure the flip-over point and platform main section are
aligned and even with each other. [Figure 16.2]
•
If needed, adjust the angle between the 2 platform sections by turning the 2 adjuster bolts at the underside of the flip-over point.
Loosen the counter nuts, then adjust the bolt length and retighten the adjuster nuts. [1 in Figure 16.2]. Make sure both sides are
adjusted equally, so that all bolts will the support the platform and its load evenly.
Figure 16.1