6
IMPORTANT!
This appliance may be installed either into a
solid non-combustible opening or into an
enclosure fabricated from non-combustible
sheet material as per the specifications in
these instructions. For installation
instructions covering the approved enclosure
design please proceed to page 9.
D
IRECT
A
IR
A
DAPTOR AND
C
ONVECTION
D
UCT
K
ITS
If fitting either the Direct Air Adaptor Kit or
Convection Duct Kit the dimensions of the
opening may need to be altered. Read the
instructions supplied with the kit before
proceeding.
I
NSTALLATION INTO A SOLID NON
-
COMBUSTIBLE
WALL
This stove must be fitted on a hearth or base
with adequate load bearing capacity. The
opening into which this stove is fitted should
be constructed wholly from non-combustible
materials. The dimensions of the opening
should be
at least
those shown in the
diagram. Ensure there is a sufficient overlap
where the convection chamber flange meets
the face of the opening. If not, either the
opening should be made smaller, or a suitable
fire surround should be fitted to reduce the
opening dimensions.
Any non-combustible walls within 50mm of
this appliance should be at least 200mm
thick and should extend at least 300mm
above the top of the appliance and at least
1.2 metres above the hearth. Any walls more
than 50mm from the appliance may be
reduced to a thickness of 75mm. Ensure the
inter-connecting flue pipe also has adequate
clearances to combustible materials.
The wall above the stove will become hot and
should therefore be finished in a heat
resistant plaster.
IMPORTANT Do not hang
pictures, electrical equipment or ornaments
above the stove, as these could be damaged
and could potentially create a fire hazard.