Dialogic® Vision™ CX Video Gateway Administration ManualFine tuning the CX Video Gateway configuration
Settings for the ISUP models with Vision™ Signaling Servers
Use the VS
_
isup
_
server keyword to specify information for ISUP models with
Signaling Servers. Replace the parameters shown in the table with the appropriate
values.
VS
_
isup
_
server 1 1
ISUP_start_circuit SS7_node_pc SS7_switch_type
signaling_and_bearer_type
Parameter
Description
ISUP_start_circuit
Circuit identifier of the first circuit that the signaling server will
handle.
SS7_node_pc
Point code assigned to the signaling server in the ISUP network.
SS7_switch_type
SS7 protocol variant that the signaling server uses. Valid values are:
•
ANS88 = ANSI 88 (ref. T1.123 – 1988)
•
ANS92 = ANSI 92 (ref. T1.113 – 1992)
•
ANS95 = ANSI 95 (ref. T1.113 – 1995)
•
ANSIBICC = ANSI BICC (T1.BICC.1-2000 to T1.BICC.7-2000)
•
ETSIV2 = ETSI v2 (ETS 300 356)
•
ETSIV3 = ETSI v3 (ETS 300 356-1 – 1998)
•
ITU97 = ITU-T 1997
•
ITUBICC = ITU-T BICC (Q.1901, Q.1902-6)
•
ITUBLUE = ITU-T Blue Book
•
ITUWHITE = ITU-T White Book
•
JTTC = JTTC (Japan TTC)
•
JNTT = JNTT (Japan NTT)
•
Q767= ITU-T Q.767
signaling_and_bearer_type
Signaling and bearer type that the signaling server uses. Valid values
are:
•
ISUP = ISUP
•
BICC+IP = BICC with IP bearer channels
Default: ISUP.
The following
telecom.conf
file example shows how to configure two Vision™
Signaling Servers. In this example, Signaling Server 1 services circuit 121 and
higher, and uses point code 100. Signaling Server 2 services circuits 1 - 120, and
uses point code 200. Both signaling servers support the ETSIV2 ISUP protocol
variant.
# Signaling board
VS
_
isup
_
server 1 1 121 100 ETSIV2 ISUP
VS
_
isup
_
server 2 2 1 200 ETSIV2 ISUP
The following
telecom.conf
file example shows how to configure a Vision™ Signaling
Server to use ITU-T BICC over IP.
# Signaling board
VS
_
isup
_
server 1 1 1 204 ITUBICC BICC+IP
Dialogic