4. PRIOR TO USE

A. 

Remove any excess dust/dirt from exterior housing and control panel.

B. 

Be sure the HEPA Filter and Pre-Filters are installed properly with a 

positive seal.

C. 

Insure the unit is connected to a dedicated 10Amp, 

110/115 volt circuit.

D. 

Make sure unit is safely positioned as not to impede any entrances or 

exits of the work area.

E. 

If applicable, check exhaust port connections for tight seal.

CAUTION:

 

Insure your power cord is securely attached to the male 

recessed plug. If any movement or play is detected, change power 

cord immediately! If connection remains loose, immediately

replace the male recessed plug.

OPERATION

A. 

When utilized in containment, the AS-1000 should be positioned a 

minimum distance away from the entrance and located towards the 

center of the containment.

B. 

When using a HEPA filter, insure the filter is correctly installed and 

sealed. Anchor and secure the filter utilizing the supplied retaining 

brackets.

C. 

Install the Ring Filter and Pre-Filter pad into unit.

D. 

Insert the female end of your 10 amp rated, UL listed cord, into the 

male recessed plug on control panel.

E. 

To begin operation, depress the power switch to either the low or high 

position. Locate the differential pressure gauge located on the control 

panel. The gauge will register between 1.0” – 1.2” of water column. This 

is the initial reading when filters are new and unused. This reading will 

incrementally increase as filters become loaded with dust and debris. 

When the gauge reaches 1.6” – 1.8” of water column; either one or all 

of the filters are loaded and in need of replacement.

F. 

Pressing the power switch to the left will operate the unit in “Low” mode 

equivalent to 500 CFM.

G. 

Pressing the power switch to the right will operate the unit in “High” 

mode equivalent to 1000 CFM.

5. REPLACEMENT OF FILTERS

The work atmosphere will impact the frequency of filter replacements. As 

filters begin to load, the reading of the pressure gauge will increase

incrementally. When the Pressure gauge reads 1.6” - 1.8” or when airflow

is greatly reduced, check the condition of filters.

CAUTION:

 

If applicable, wear personal protective equipment during 

filter replacement. Please observe all Federal, State, and Local 

regulations regarding the handling and disposal of 

hazardous materials.

PRE-FILTER REPLACEMENT

A. 

Set the power switch (diagram #20.1, item #3) to the off position. 

Disconnect power supply.

B. 

Remove Black Filter Door (diagram #20.1, item #22) to expose the 

filters.

C. 

Reach in and remove the Pre-Filter (diagram #20.1, item #18). 

Dispose of Pre-Filter accordingly.

D. 

Replace the discarded Pre-Filter with a new Pre-Filter.

E. 

Reinsert the Black Filter Door (diagram #20.1, item #22).

F. 

Insert the female end of your power cord into the Male recessed plug 

(diagram #20.1, item #1), and set the power switch to the “High” posi-

tion. If the reading on the pressure gauge exceeds 1.6” – 1.8”” of water 

column, the Ring Filter #17 should be inspected.

RING FILTER REPLACEMENT

A. 

Follow steps A-D listed above referencing Pre-Filter replacement.

B. 

Reach in and remove the Ring Filter (#17). 

Dispose of Ring Filter accordingly.

C. 

Replace the discarded filter with a new unused Ring Filter.

D. 

Reinstall the Pre-Filter (#18). 

E. 

Reinsert the Black Filter Door (#22). 

F. 

Insert the female end of your power cord into the male recessed plug 

(diagram #20.1, item #1), and set the power switch to the “High” posi-

tion. If the reading on the pressure gauge exceeds 1.6” – 1.8” of water 

column, the Ring Filter #17 should be inspected. 

HEPA/GENERAL PURPOSE 

FILTER

A. 

Follow steps A-D listed above for Ring Filter replacement.

B. 

Locate the bracket thumbscrews (diagram #20.1, item #11). Loosen the 

four bracket thumbscrews by turning them counter clockwise.

C. 

With all four thumbscrews loose, push the top of the filter brackets 

(diagram #20.1, item #10) inward towards each other, and remove from 

the top of the unit.

D. 

Firmly grasp the right and left sides of the HEPA Filter, (diagram #20.1, 

item #16), and pull the Filter upward. Remove the used HEPA Filter and 

dispose of accordingly

E. 

Carefully Inspect the HEPA Filters gasket for cracks, gaps or defects.  

Any defective gaskets must be replaced.

F. 

The HEPA filter has two sides. One side is has a gasket, the other is 

not. Insert the side with the gasket of the HEPA Filter first and press 

firmly against the housings internal rib.

G. 

Reinstall the filter brackets. Once the brackets are installed, turn the 

thumbscrews clockwise until tight. This will secure the HEPA Filter.

H. 

Reinstall Ring Filter and Pre-Filter. (Reference Pre-Filter and Ring Filter 

Replacement).

I. 

Reinsert the Black Filter Door (#22).

Summary of Contents for AS-1000

Page 1: ...OWNER S MANUAL AS 1000 AIR SCRUBBER USER MAINTENANCE BOOK SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE ...

Page 2: ...rformed This may include dust mask or other breathing appara tus safety glasses ear plugs gloves apron safety shoes hard hat and other equipment n If applicable prevent exposure and breathing of harmful dust and particles Some dust created by power sanding sawing and grinding drilling and other construction activities contains chemicals known to cause cancer birth defects or other reproductive har...

Page 3: ...ction A Clean the surfaces of the unit to remove accumulated dust or dirt Do not use petroleum distillates solvents or thinners as cleaning agents Remove any accumulated dust and dirt from control panel B Periodic checks should be made of the filter brackets to ensure thumbscrews and knobs are secure C Filters should be checked daily and replaced if needed This will help ensure proper air flow and...

Page 4: ...Federal State and Local regulations regarding the handling and disposal of hazardous materials PRE FILTER REPLACEMENT A Set the power switch diagram 20 1 item 3 to the off position Disconnect power supply B Remove Black Filter Door diagram 20 1 item 22 to expose the filters C Reach in and remove the Pre Filter diagram 20 1 item 18 Dispose of Pre Filter accordingly D Replace the discarded Pre Filte...

Page 5: ...6 WIRING DIAGRAM ...

Page 6: ...6 PARTS BREAKDOWN ...

Page 7: ...KNOB DP AS 1000 INTAKEPOLYDOOR Description Male Recessed Plug Breaker Power Switch Pressure Gauge Barbed Pressure Fitting Dome Wire Nut Blower Housing Wheel Blower Motor Capacitor Blower Assembly Complete Filter Brackets Thumbscrews Wheels 8 Axle Axle Brackets Skid Wear Pad Hepa Filter 1000CFM General Filter Frame General Filter Ring Filter Pre Filter Audible Visual Alarm optional N A Knob for Doo...

Page 8: ...aker is extended this indicates the circuit breaker requires re setting Reset the circuit breaker by depressing the center of the circuit breaker If the center fails to remain depressed replace the circuit breaker immediately n If unit continues not to function Check the power supply in the work area Be sure power is being supplied to the unit n If at this point unit still will not operate Contact...