5.
Maintenance
Check regularly to see if the diamond disc is in good condition. Replace immediately the diamond disc when this is damaged
or worn out.
Check if the flexible coupling is stiff enough, after every 2 diamond disc changes. Replace if any deformation or damage is
found, replace the coupling after use of 7 diamond discs.
Unusual vibrations on the machine check immediately the diamond disc and flexible coupling
Replacing the flexible coupling:
•
Pull out the main plug
•
Remove the diamond disc
•
Remove the protection cap
•
Loose the bolts of the adapter plate and the flexible coupling
•
Take a new flexible coupling and assemble this together with the adapter plate on the fixed coupling on the motor
axle
•
Assemble the protection cap
Prevent premature wear by keeping the machine as dust free as possible. Clean the machine for this reason regularly with a
dust collector
Clean the machine every day with air and non-aggressive materials. Never use a high pressure water cleaner to clean the
machine.
Remove the diamond disc after using the machine
Store the cleaned and dry machine in a dry and humid free room. Protect the electrical motor from moisture, heat, dust and
shocks.
All repair work must to be done by qualified Diamatic personnel, this to guarantee a safe and reliable machine.
Any guarantee on the machine is expired when:
•
Non original Diamatic parts and diamond discs have been used
•
Repair work is not done by qualified Diamatic personnel
•
Changes, add on’s or conversions are undertaken without written permission of Diamatic