background image

 

Element Series Manual 

 

Page | 1  

 

Element (ELE-800, ELE-1600, ELE-1800, ELE-2400, ELE-
4800, ELE-7200) Manual 

Inspect the packaging

 of the equipment to confirm that nothing was damaged during 

shipping.  

Remove the system from the packaging

. Make sure everything is included and without 

damage. Below is a checklist of the major components to check. The system will 
already be assembled and should arrive in one piece. 

_____ 1) Pump 
_____ 2) Front Panel 
_____ 3) Membrane Housing(s) 
_____ 4) Filter Housing 

Call Diamond H2O right away if anything is missing. Contact the freight company 

immediately

 if anything is damaged. Diamond H2O will not be liable for any damage received after shipping. 

Packaged By: ___________________________________              Date: _______________ 
 
Received By:  ___________________________________  

Date: _______________ 

Warnings 

1.

 

System produces Corrosive Water. 

The element produces water with very low Total Dissolved Solids (TDS) and is 

corrosive

Product/Permeate water should not be exposed to metal piping like brass, copper, or steel. Systems 
installed on metallic plumbing must use Pro Products LLC Neutra 7 for protection from corrosion. 

2.

 

System produces Concentrated Water. 

The element produces water with very high TDS which can be dangerous. Concentrate/Reject water will 
contain a higher concentration of most contaminants than the source water and should not be used as 
drinking water.  

3.

 

120/240V present in control box 

To reduce the risk of electrical shock, the incoming power supply must include a protective earth ground.

 

4.

 

Pump will boost pressure by approximately 150psi.  

5.

 

Use on board TDS monitor as a secondary reference only. 

TDS is a general indication of all the ions present in water. A reduction in TDS does not necessarily mean a 
reduction in a specific contaminant. Testing for specific contaminants at least annually is recommended.  
 

Contact 

TG

 Analytical Labs

 

with any questions on testing coliform 

bacteria, nitrate, arsenic

, and more. 

Email: 

info@tgalabs.com

          Phone: 920-757-1355          Fax: 920-757-5819 

Summary of Contents for Element ELE-1600

Page 1: ...olved Solids TDS and is corrosive Product Permeate water should not be exposed to metal piping like brass copper or steel Systems installed on metallic plumbing must use Pro Products LLC Neutra 7 for protection from corrosion 2 System produces Concentrated Water The element produces water with very high TDS which can be dangerous Concentrate Reject water will contain a higher concentration of most...

Page 2: ...there is no pressure from the supply c Plumb the water source to the FPT inlet Supply In d Plumb the MPT Permeate Outlet to its endpoint this will contain product water e Plumb the MPT Concentrate Outlet to its endpoint this will contain concentrate water f Either the concentrate or permeate outlet must not be plumbed to a pressurized line If both outlets are pressurized the system will not prime ...

Page 3: ...the membrane Installing a water softener before each system to reduce hardness and iron is recommended 4 Anti Scalent recommended Slightly soluble contaminants like calcium sulfate silica or colloidal clay will cause clogging A continuous injection of an anti scalent should be used if these contaminants are present Recommended Specifications Total Dissolved Solids 2000 ppm Hardness 17 ppm Iron 0 1...

Page 4: ...Element Series Manual Page 4 Control A diagram of the Element controller is shown below ...

Page 5: ...Element Series Manual Page 5 Inner Control Box ...

Page 6: ...Element Series Manual Page 6 CPU Board Diagram ...

Page 7: ...Element Series Manual Page 7 DIP Switch Settings See Page 8 for details on RO Program settings ...

Page 8: ...lush Program 3 Permeate flush low pressure inlet valve closed Program 4 Low pressure feed water flush The program details are shown below These features are disabled by default due to the potential for confusion on the part of end users in the field They can be enabled when needed via the OEM PC programming interface which allows changes to all of the values shown above ...

Page 9: ...Element Series Manual Page 9 Control Programming Parameters Explained ...

Page 10: ...Element Series Manual Page 10 Control Programming Parameters Explained Continued ...

Page 11: ...ottom of the filter housing by rotating counterclockwise Excessive force does not need to be used when tightening the housing but the housing should be secure and snug Changing a Membrane 1 Turn off the control and the incoming water supply and depressurize the incoming water line 2 Remove screws from top of membrane 3 Remove 2 metal securing brackets from top of membrane 4 Slide membrane changing...

Page 12: ...Element Series Manual Page 12 Notes ...

Reviews: