Element Series Manual 

 

Page | 2  

 

Setup Instructions 

1.

 

Find the location. 

Decide where you would like to place the system. Allow at 
least 45 inches above the unit for membrane removal and 
loading. If the height is not available, allow at least 25 
inches to the front of the unit for the removal of the entire 
membrane housing.  

The unit will also need to be installed near a 

120/240 VAC

60/50Hz power supply (Range: 90-145 VAC at 120VAC 
setting, 180-290 VAC at 240 VAC setting). 

2.

 

Install Float Switch (or other operation control) 

If the system uses a holding tank, a float switch must be installed to control the system’s production.

 

Install the float switch in the holding tank and connect the switch to the correct terminals on the control 
(Check the Terminal Board Diagram). 

 

3.

 

Plumb in the system. 

Follow All Local Codes 

a.

 

Verify inlet water source meets requirements on page 4. 

b.

 

Turn off water from the supply water and make sure there is no pressure from the supply. 

c.

 

Plumb the water source to the 

¾” FPT

 

inlet (“Supply In”)

.  

d.

 

Plumb the ½” MPT Permeate Outlet to 

its endpoint (this will contain product water) 

e.

 

Plumb the ½” MPT Concentrate Outlet to its endpoint (this will contain 

concentrate water) 

f.

 

Either the concentrate or permeate outlet must not be plumbed to a pressurized line. If both outlets 
are pressurized, the system will not prime properly.  

4.

 

Prime the system. 

Turn on water from the supply and re-pressurize the incoming water line. 
Use the relief valves to help relieve any air pressure that may have built up in 
the water line. Once water begins coming out of the pressure relief valve, 
the system may be turned on. The control will automatically prime the 
pump.  

5.

 

Start up. 

Most, if not all, of the programming will be set for the individual application 
during production. Plug the controller in and verify that the system has been 
programmed correctly and press System On/Off to turn on the system. During startup, the system will 
automatically prime the pump and begin operation after 15 seconds. 

 

 

Permeate Outlet 
(product) 

Concentrate Outlet 
(Reject) 

Inlet 

Summary of Contents for Element ELE-1600

Page 1: ...olved Solids TDS and is corrosive Product Permeate water should not be exposed to metal piping like brass copper or steel Systems installed on metallic plumbing must use Pro Products LLC Neutra 7 for protection from corrosion 2 System produces Concentrated Water The element produces water with very high TDS which can be dangerous Concentrate Reject water will contain a higher concentration of most...

Page 2: ...there is no pressure from the supply c Plumb the water source to the FPT inlet Supply In d Plumb the MPT Permeate Outlet to its endpoint this will contain product water e Plumb the MPT Concentrate Outlet to its endpoint this will contain concentrate water f Either the concentrate or permeate outlet must not be plumbed to a pressurized line If both outlets are pressurized the system will not prime ...

Page 3: ...the membrane Installing a water softener before each system to reduce hardness and iron is recommended 4 Anti Scalent recommended Slightly soluble contaminants like calcium sulfate silica or colloidal clay will cause clogging A continuous injection of an anti scalent should be used if these contaminants are present Recommended Specifications Total Dissolved Solids 2000 ppm Hardness 17 ppm Iron 0 1...

Page 4: ...Element Series Manual Page 4 Control A diagram of the Element controller is shown below ...

Page 5: ...Element Series Manual Page 5 Inner Control Box ...

Page 6: ...Element Series Manual Page 6 CPU Board Diagram ...

Page 7: ...Element Series Manual Page 7 DIP Switch Settings See Page 8 for details on RO Program settings ...

Page 8: ...lush Program 3 Permeate flush low pressure inlet valve closed Program 4 Low pressure feed water flush The program details are shown below These features are disabled by default due to the potential for confusion on the part of end users in the field They can be enabled when needed via the OEM PC programming interface which allows changes to all of the values shown above ...

Page 9: ...Element Series Manual Page 9 Control Programming Parameters Explained ...

Page 10: ...Element Series Manual Page 10 Control Programming Parameters Explained Continued ...

Page 11: ...ottom of the filter housing by rotating counterclockwise Excessive force does not need to be used when tightening the housing but the housing should be secure and snug Changing a Membrane 1 Turn off the control and the incoming water supply and depressurize the incoming water line 2 Remove screws from top of membrane 3 Remove 2 metal securing brackets from top of membrane 4 Slide membrane changing...

Page 12: ...Element Series Manual Page 12 Notes ...

Reviews: