background image

10 

5.2 - Operation 

  

WARNING!

 

The device is specially designed for working on a programmed basis, thus for activating 
after it has been programmed and activated. The device, therefore, does not require the 
direct intervention of an operator to physically start, but activates automatically on the basis 
of the set programme. 
The programming and subsequent activation of the device are thus very important phases 
and must be carried out by qualified personnel possessing an in-depth knowledge of this 
manual and also of ozone’s effects on people, animals and the environment.  
The chosen person must have a hierarchical role within the organisation and must have the 
power to organise, arrange and check to ensure that: 

no people or animals are present while the appliance is running and in the hours 
immediately afterwards; 

the appliance cannot be tampered with or re-programmed by people not directly 
instructed by him/her; 

internal protocols are drawn up and adequate information is provided (for example, 
warning and hazard signs, etc.).

 

 
Ozone has a high oxidising power, which makes it effective in destroying germs, bacteria 
and mould and in passivating viral loads on surfaces, objects and in the air. 
To sanitise the environments correctly, programme the device on the basis of the 
respective programming table shown on page 11.  
The actual O

3

 production capacity of the device is shown in the technical data table (see 

page 6) and the production is expressed in g/h (grams per hour). 
All the devices we manufacture are suitable for use in medium-sized open-space 
environments. The layout of the environments and the equipment present in them may 
prevent or limit the correct and uniform diffusion of O

3

 throughout the room. 

Due to its intrinsic properties, ozone will tend to dissipate naturally once the device stops 
working. We nonetheless recommend not returning to the treated rooms unless at least 6 
hours have elapsed from the end of the cycle, after ventilating them thoroughly and leaving 
the area for at least a further 15 minutes to allow a total change of air, before the area is 
used again permanently. 
Remove the plug from the power outlet and store the device in a place accessible only to 
the person responsible for its use. 

 

WARNING!  

Ozone has a strong oxidising effect that is hazardous to health.  

Prolonged exposure to ozone causes oxidation and therefore ageing of surfaces and 
materials (in particular plastic or rubber materials, non-treated steels, etc.) or electrical or 
electronic equipment. 

Summary of Contents for 61051122

Page 1: ...10 2021 Mod OZONE 112MC Production code 61051122 ...

Page 2: ...OPERATING AND MAINTENANCE MANUAL English ...

Page 3: ...d use 1 5 Improper use 1 6 Technical data 1 7 Composition of the generator CH 2 TECHNICAL DATA 7 2 1 Overall dimensions weight specifications CH 3 RECEIVING THE DEVICE 8 3 1 Shipping 3 2 Inspection of the packaging on delivery 3 3 Disposal of packaging CH 4 INSTALLATION 9 4 1 Positioning 4 2 Connection to the power supply 4 3 Wiring diagram 4 3 1 220 240 V 50 Hz CH 5 USING THE DEVICE 10 5 1 Contro...

Page 4: ... of or poor maintenance use of non original spare parts not specifically designed for the model total or partial failure to follow the instructions given in this manual treatment of the device s surfaces with unsuitable products 1 2 Safety devices installed on the device The safety devices against electrical risks conform to EU Directive 2014 35 and the 60335 1 standard The ozone generator is ther...

Page 5: ...a machine for generating ozone intended for other purposes Do not use the device unless it has been properly positioned with all its guards in good working order to prevent the risk of serious personal injury Do not access the components to avoid the risk of electrocution Do not start up the equipment if it is clearly or presumably faulty Before using the device make sure that any potentially haza...

Page 6: ...ndi 3 Emissione O3 OUT 6 Cavo di alimentazione Fig n 2 LE CARATTERISTICHE ELETTRICHE PER LE QUALI E PREDISPOSTA L APPARECCHIO SONO INDICATE IN UNA TARGHETTA APPLICATA SUL RETRO DELLA STESSA PRIMA DI ESEGUIRE L ALLACCIAMENTO VEDERE PUNTO ALLACCIAMENTO ELETTRICO 5 6 2 IN 1 3 O3 OUT 4 ...

Page 7: ... watt 740 Power supply 220 240V 50 Hz Rated O3 production g h 112 Timer min 60 Fan m3 h 165x2 A x B mm 322x145 C x D mm 336x186 E mm 1806 F mm 176 Net weight kg 14 5 the rated data refers to tests conducted in a room with 100 oxygen The actual production is therefore proportional to the percentage of oxygen in the air which is generally around 20 22 ...

Page 8: ...ipping If the packaging shows signs of mishandling impacts or dropping report the damage to the shipping agent within three days of the date of delivery indicated on the documents and draw up a detailed report on any damage to the machine 3 3 Disposal of the packaging The packaging materials cardboard box plastic strap and polystyrene or polyurethane foam can be disposed of together with normal ho...

Page 9: ...g in between Fig 5 Fig n 6 4 2 Connection to the power supply The device comes with a power cable having a cross sectional size of 3x1 5 mm a length of 1 5 m and a Schuko plug Connect the device to the 220 240 V 50 Hz power supply while making sure that the system complies perfectly with the standards and includes a 0 03 A 10 A residual current circuit breaker Moreover check that the information o...

Page 10: ...rogrammed operation without having to intervene on the weekly clock Finder programmer model 12 61 8 230 Ref 2 Fig 7 can be used for adjusting the appliance for cyclical weekly programming To programme the clock on a weekly basis refer to the enclosed instructions from page 12 The Finder programmer model 12 61 8 230 is also equipped with a handy app based programming system for Android and iOS smar...

Page 11: ...iral loads on surfaces objects and in the air To sanitise the environments correctly programme the device on the basis of the respective programming table shown on page 11 The actual O3 production capacity of the device is shown in the technical data table see page 6 and the production is expressed in g h grams per hour All the devices we manufacture are suitable for use in medium sized open space...

Page 12: ... 1 ppm medium sanitisation bacteria 70 viruses 80 fungi animal parasites environmental odours 2 ppm strong sanitisation bacteria 99 viruses and mites 95 moulds animal parasites environmental odours Programming table O3 112 Nominal production Concentration Timer 20 min Timer 40 min Ppm mc mc mq mc Mq mc Mq 112 g h 1 ppm 600 200 1080 360 1320 440 2 ppm 360 120 600 200 1080 240 Timer 60 min ...

Page 13: ...12 ...

Page 14: ...13 ...

Page 15: ...14 ...

Page 16: ...15 ...

Page 17: ...16 ...

Page 18: ...17 ...

Page 19: ...crubbing brushes or anything that may damage the surface of the device Do not introduce tools or brushes inside the device Do not wet the machine or any of its parts nor wash it in a dishwasher 6 2 Maintenance To protect the device against dust build up we recommend storing it in a dry and dust free place for example in its original packaging in a cabinet etc CH 7 MAINTENANCE 7 1 General informati...

Page 20: ...sal The crossed out wheelie bin symbol on the equipment or on its packaging indicates that the product must be disposed of separately from other waste at the end of its useful life The separate waste collection of this device at the end of its life is organised and managed by the manufacturer The user who wishes to dispose of this device must contact the manufacturer and follow the given instructi...

Reviews: